![background image](http://html2.mh-extra.com/html/daikin/r-410a/r-410a_technical-data-manual_5689022007.webp)
• Split Sky Air • Outdoor Units
5
• Outdoor Units • R-410A • RXS-G2V1B
2
Specifications
3
2
Power Input
Cooling
Minimum
kW
0.30
0.30
0.45
Standard
kW
0.65
1.13
1.72
Maximum
kW
0.86
1.26
1.95
Heating
Minimum
kW
0.29
0.29
0.31
Standard
kW
0.98
1.23
1.82
Maximum
kW
1.49
1.85
3.54
For combination
indoor units +
outdoor units
EER
Nominal
3.85
3.10
2.85
COP
Nominal
3.47
3.25
3.35
Energy Label
Cooling
A
B
C
Heating
B
C
C
Annual energy consumption
kWh
325
565
860
Indoor Units
FFQ25B8V1B
FFQ35B8V1B
FFQ50B8V1B
Cooling capacity
Standard
kW
2.50
3.40
4.70
Heating capacity
Standard
kW
3.20
4.00
5.50
Power Input
Cooling
Standard
kW
0.73
1.10
1.80
Heating
Standard
kW
0.92
1.20
1.96
For combination
indoor units +
outdoor units
EER
Nominal
3.42
3.09
2.61
COP
Nominal
3.48
3.33
2.81
Energy Label
Cooling
A
B
D
Heating
B
C
D
Annual energy consumption
kWh
365
550
900
Indoor Units
FCQ35C7VEB
FCQ50C7VEB
Cooling capacity
Standard
kW
3.40
5.00
Heating capacity
Standard
kW
4.20
6.00
Power Input
Cooling
Standard
kW
0.95
1.41
Heating
Standard
kW
1.23
1.62
For combination
indoor units +
outdoor units
EER
Nominal
3.58
3.55
COP
Nominal
3.41
3.70
Energy Label
Cooling
A
A
Heating
B
A
Annual energy consumption
kWh
475
705
Indoor Units
FHQ35BVV1B
FHQ50BVV1B
Cooling capacity
Minimum
kW
1.4
1.7
Btu/h
4,800
5,800
Kcal/h
1,200
1,460
Standard
kW
3.4
5.0
Btu/h
11,600
17,100
Kcal/h
2,920
4,300
Maximum
kW
3.7
5.6
Btu/h
12,600
19,100
Kcal/h
3,180
4,820
Heating capacity
Minimum
kW
1.2
1.7
Btu/h
4,100
5,800
Kcal/h
1,200
1,460
Standard
kW
4.0
6.0
Btu/h
13,650
20,500
Kcal/h
3,440
5,160
Maximum
kW
5.0
7.0
Btu/h
17,100
23,700
Kcal/h
4,300
6,020
Power Input
Cooling
Minimum
kW
0.44
Standard
kW
1.05
1.83
Maximum
kW
2.02
Heating
Minimum
kW
0.40
Standard
kW
1.11
2.05
Maximum
kW
2.45
2-1 NOMINAL CAPACITY AND NOMINAL INPUT
RXS20G2V1B
RXS25G2V1B
RXS35G2V1B
RXS42G2V1B
RXS50G2V1B