5 Unit installation
Installation manual
6
CVXM-A, FVXM-A, CVXM-A9, FVXM-A9, FVXTM-A
Split system air conditioners
3P477070-2P – 2022.09
Example:
If the indoor unit is installed in room with floor area
4.99 m
2
, ceiling height 2 m, located above ground level, than the
total refrigerant change is ≤2.3 kg.
5.2
Mounting the indoor unit
5.2.1
To install the indoor unit
Installation options
There are 3 possible type of installation for the indoor unit.
a
b
A
B
C
A
Floor (exposed) installation
B
Wall (exposed) installation
C
Half concealed installation
a
Mounting plate
b
Skirting board
Floor-standing installation
(mm)
627.5
750
00
6
300
200
285
115
159
238
689
a
a
a
a
159
a
a
75
06
75
45
Ø65
Ø65
45
b
c
75
75
54
f
e
A
B
C
54
45
d
5‒1 Indoor unit installation drawing: Floor-standing installation
A
Front view
B
Side view
C
Top view
a
Screw hole 6×
b
Left-back piping hole location
c
Right-back piping hole location
d
Left/right piping hole location
e
Left-bottom piping hole location
f
Right-bottom piping hole location
1
Drill a wall hole, depending on which side piping is taken out.
See
8].
2
Open the front panel and remove the front grille.
3
Remove the slit portions using nippers. See
8].
4
Secure the unit to the wall and floor using 6 screws M4×25L
(field supply).
6×
5
When the complete installation is finished, attach the front panel
and the front grille in their original position.
Wall-mounted installation
82
166
06
≤
(mm)
627.5
750
00
6
553
300
200
285
115
238
b
b
b
b
75
06
75
45
Ø65
Ø65
45
d
e
75
75
54
h
g
54
45
f
A
B
C
c
c
a
5‒2 Indoor unit installation drawing: Wall-mounted installation
A
Front view
B
Side view
C
Top view
a
Mounting plate
b
Screw hole 4×
c
Floor
d
Left-back piping hole location
e
Right-back piping hole location
f
Left/right piping hole location
g
Left-bottom piping hole location
h
Right-bottom piping hole location
6
Temporarily secure the mounting plate on the wall.
7
Make sure the mounting plate is level.
8
Mark the centres of the drilling points on the wall.
9
Secure the mounting plate on the wall using 5 screws M4×25L
(field supply).