6
|
Unit installation
Installer reference guide
26
C FVXM25~50A
Split system air conditioners
4P625991-1C – 2021.09
b
Wiring box cover
c
Tabs
6.3 Mounting the indoor unit
6.3.1 To install the indoor unit
Installation options
There are 3 possible type of installation for the indoor unit.
a
b
A
B
C
A
Floor (exposed) installation
B
Wall (exposed) installation
C
Half concealed installation
a
Mounting plate
b
Skirting board
Floor-standing installation
(mm)
627.5
750
00
6
300
200
285
115
159
238
689
a
a
a
a
159
a
a
75
06
75
45
Ø65
Ø65
45
b
c
75
75
54
f
e
A
B
C
54
45
d
6‒1 Indoor unit installation drawing: Floor-standing installation
A
Front view
B
Side view
C
Top view
a
Screw hole 6×
b
Left-back piping hole location
c
Right-back piping hole location
d
Left/right piping hole location
e
Left-bottom piping hole location
f
Right-bottom piping hole location
1
Drill a wall hole, depending on which side piping is taken out. See
30].
2
Open the front panel and remove the front grille (see