6
|
Unit installation
Installer reference guide
24
C FVXM25~50A
Split system air conditioners
4P625991-1C – 2021.09
≤
60
(65)
≤27°
(mm)
≥467
≥50
≥50
A
B
(105)
≤
60
A
Front view
B
Side view
▪
Do not install the unit more than 60 mm above the floor.
6.2 Opening the indoor unit
6.2.1 To remove the front panel
1
Slide both sliders in the direction of the arrows until they click.
2
Open the front panel and remove the string.
3
Remove the front panel.
6.2.2 To remove the front grille
1
"6.2.1 To remove the front panel"
2
Remove the 4 screws, remove the grille from 4 tabs on the top and remove
the front grille while pulling it toward you.