IM 1016-2 • MTB 158 MICROPROCESSOR THERMOSTAT

 2 

www.DaikinApplied.com

 

Figure 1: 

Wiring Diagram for 3-Wire Valve Configuration  

   

Figure 2: 

Wiring Diagram for ON/OFF Ouput Configuration   

   

Table 1: 

Ratings 

Voltage 

Rating

Fan and system switches

Thermostatic 

Switching  

(Pilot Duty) 

Inductive

Resistive 

Amps

Pilot Duty

FLA

LRA

24 VAC

N.A.

N.A.

N.A.

24 VA

10 VA

120 VAC

5.8

34.8

6.0

125 VA

NA

240 VAC

2.9

17.4

5.0

125 VA

NA

277 VAC

2.4

14.4

4.2

125 VA

NA

Thermostat Operation 

These thermostats are designed to control ON-OFF, N.O. 

and N.C. valves, relays and three-wire floating valves. These 

units may include a fan switch with one or more fan speed 

selections. 

Table 2: 

Main and Secondary Output Operation* 

Output

3-Wire  

Floating

OFF  

with Demand

ON  

with Demand

Main 1  

(Terminal 10)

Powers main 

valve open

ON at temp 

demand

ON at temp 

demand

Main 2  

(Terminal 12)

Powers main 

valve closed

Cycles ON with 

demand

Cycles ON with 

demand

Secondary  

(Terminal 11)

Powers secondary 

valve open

Summer: OFF 

with heat demand

Winter: Disabled

Summer: ON with 

heat demand

Winter: Disabled

Secondary 2  

(Terminal 13)

Powers secondary 

valve closed

ON at second 

stage heating 

demand

ON at second 

stage heating 

demand

Note: 

* Operation determined by configuration. See Dip Switch Configuration 

Table.

Mode Button Operation 

OFF:

 All thermostat outputs are off, fan is still operational if 

connected to manual fan speed switch. 

AUTO:

 The thermostat automatically selects heating or cooling 

mode depending on the set point and room temperature. The 

appropriate HEAT or COOL indicator is enabled in addition to 

AUTO. A 3°F dead-band is provided to prevent short cycling 

between heating and cooling modes. 
After change-over the control points automatically shift so that 

the heating OFF-point or the cooling OFF-point equals the set 

point temperature. 

COOL:

 The thermostat operates as a cooling-only thermostat. 

The heating outputs are disabled. 

HEAT:

 The thermostat operates as a heating-only thermostat. 

The cooling outputs are disabled. 
If constructed without a mode button, the thermostat operates 

in Auto mode, subject to configuration of the 2/4 pipe jumper 

and pipe sensor input. 

LO

VO

LT

AG

E

CO

NNE

CT

IO

NS

LI

NE

 VO

LT

AG

E

C

ON

N

E

CT

IO

NS

L1 (HOT)

LO 

MED 

24 VAC 1

24 VAC 2

SETBACK INPUT 

MAIN 1 OPEN

SEC 1 OPEN

MAIN 2 CLOSE

SEC 2 CLOSE

REMOTE PROBE

PIPE SENSOR

FAN

L2 OR NEUTRAL

24 VAC

XFMR

MAIN

SECONDARY

OUTSIDE AIR

DAMPER OUTPUT

10

11

12

13

14

15

16

17

1

2

3

4

5
6

7

HIGH 
OR SINGLE SPEED FAN

LO

VO

LT

AG

E

CO

N

NE

C

T

ION

S

LI

NE

 VO

LT

AG

E

CO

NN

EC

TI

ON

S

FAN

L2 OR NEUTRAL

REMOTE PROBE

PIPE SENSOR

L1 (HOT)

LO

MED 

HIGH 

OR SINGLE SPEED FAN

24 VAC 1  

24 VAC 2 

SETBACK INPUT

FAN  

24 VAC

XFMR

MAIN 1

SEC 1

HEAT 2

MAIN 1

OUTPUT

SECONDARY

 1 OUTPUT

DEMAND

OUTPUT

2ND STAGE

HEAT

OUTSIDE AIR

DAMPER OUTPUT

10

11

12

13

14

15

16

17

1

2

3

4

5
6

7

Reviews: