English /
12
Contents
1) Ionizing frame
2) Ionized wire
3) Streamer discharger
4) Opposing pole plate
Remove each part.
(page 11.)
(page 11.)
(page 11.)
Vacuum dusts on the
surface with a cleaner.
Caution
• Do not remove the screws on the ionizer or streamer discharger. Breakdown may result.
Soak in water or warm
water with liquid mild
detergent. (about 1 hour)
Clean off the dirt with a
cloth or soft brush.
Caution
• Be sure to do in a shower-proof place such as bathroom or sink in a kitchen.
• Use only specified volume of liquid mild detergent.
• Do not use powder detergent or alkaline detergent and scrub with hard sponge.
Distortion or damage to the equipment may result.
Rinse with running water.
Soak in water or warm
water to remove
detergent.
(about 30 minutes)
Caution
• Soak well, as “cleaning sign” may be on even after cleaning if any detergent remains.
Rinse with running water
and then dry.
Caution
• Be careful not to leave bits of tissue such as cloth. Malfunction may result.
Dry in the breezy shade.
(about 1 day)
Caution
• Do not expose to direct sunlight. Resin part may be discolored or distorted.
• Dry in the shade, as “cleaning sign” may be on even after cleaning if any moisture remains.
Attach each part.
(page 14.)
(page 14.)
(page 14.)
Vacuum
Soak in water
with detergent
Wipe the dirt off
(For detail, see page 13.)
Wipe off
(For detail, see page 13.)
Wipe off
Scrub down
Rinse well
Soak in water
or warm water
Rinse well
Dry in the shade
01_EN_3P167171-1A.fm Page 12 Tuesday, October 18, 2005 4:14 PM
Summary of Contents for MC707VM-S