background image

6

English

1

 

About the child proof lock lamp

When lit up, operations will be restricted. When buttons are pressed, only a tone (3 short beeps) will sound, preventing misoperation by small children. 

 

Page 13

2

 About the streamer lamp

This lamp lights up when the streamer is operating. The streamer operates depending on the degree of air impurity.

• If the hissing sound generated by the streamer discharge or the smell of ozone bother you, set streamer output to low. 

 

Page 14

3

 

About the dust sensor lamp / PM2.5 INDICATOR lamp

After operation is started, the lamp will light green for the fi rst minute
(approx.) regardless of air impurity level.

The responsiveness of the dust/PM2.5 sensor may be poor during FAN setting “Turbo” or when 

airfl ow is high in AUTO FAN MODE. The strong airfl ow causes dust to be drawn into the air 

inlets before it can be detected by the dust/PM2.5 sensor. This is normal (not a malfunction).

If the responsiveness of the dust/PM2.5 sensor is poor, change the sensitivity
setting of the sensor. 

 

Page 15

Dust/PM2.5 sensor detection range

Detectable matter

house dust, tobacco smoke, pollen, mites, pet hairs, diesel particulate matter

Sometimes detectable

steam, oil smoke

4

 About the odour sensor lamp

If operation is started immediately after the power supply plug is inserted, the
lamp will light green for the fi rst minute (approx.).

If odour intensity levels are unchanging, the sensor may not respond even if there
is a strong odour in the air.

The sensor may not respond to some odours such as pet odours (excluding ammonia), garlic odour, etc.

As odour perception varies by person, in some cases an odour may be sensed
even when the lamp is green.

If the odour bothers you, switch to manual airfl ow rate, and select a high airfl ow

rate. 

 

Page 10

The ambient odour level in the fi rst minute after the unit is plugged in serves as

the reference level upon which the sensitivity of the odour sensor is determined. 
Insert the power supply plug when the air is clean (odour-free).

Odour sensor detection range

Detectable matter

tobacco odours, cooking odours, pet odours, toilet 
smells, waste smells, mould odours, sprays, alcohol

Sometimes detectable

sudden changes in temperature/humidity, steam, oil 
smoke, gas emitted from combustion-based heating 
devices

Read First

Operating/Indicator panel

When a lamp is blinking

 

 

Page 21

1

 

Child proof lock lamp [orange]

Lamp will be lit when the Child proof lock active.

MODE lamps [green]

Indicate the MODE in operation.

ON/OFF lamp [green]

Lamp will light up when the power is ON.

FAN lamps [green]

Indicates the active FAN setting (4 settings: Quiet, Low, Standard, Turbo).

3

 

Dust sensor lamp / PM2.5 INDICATOR lamp

Light indicates the volume of ambient dust.

Green indicates that the air is clean.

• The dust sensor lamp / PM2.5 INDICATOR lamp can detect small (approx. 1.0-2.5μm) and

large (approx. 2.5μm and above) dust particles. The PM2.5 INDICATOR lamp light in

response to small particles and the dust lamp lights in response to large dust particles.

Green

Orange

Red

Low

High

Lamp 

colour

Dust

[Dust sensor lamp]

Low

High

Green

Green

Lit up

Yellow Orange

Red

Purple Brown

Dust

[PM2.5 INDICATOR lamp]

2

 

Streamer lamp [blue]

Lights up when the streamer is active.

4

 Odour sensor lamp

Indicates the intensity of odours in 3 
colours: green, orange, red.

Green indicates that the air is clean.

Green

Orange

Red

Low

High

Lamp 

colour

Odours

01_EN_3P477288-1F.indd   6

9/28/2018   2:25:53 PM

Summary of Contents for MC55YPVM

Page 1: ...for purchasing this air puri er Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep the operation manual in a sa...

Page 2: ...n moisture content increased 1 8 times over approx 120 minutes Actual effects vary by operating environment and usage patterns Streamer discharge decomposes adsorbed odour Elimination of 99 of 0 1 2 5...

Page 3: ...rating the Unit in a MODE 11 AUTO FAN ECONO ANTI POLLEN Using the Child Proof Lock 13 Adjusting Indicator Lamp Brightness 13 Operation Using the Air Purifying Operation 10 Changing the Airflow Rate 10...

Page 4: ...ng may result if the power supply plug is not firmly inserted Periodically wipe dust off the power supply plug with a dry cloth If the unit is not to be used for an extended period of time unplug the...

Page 5: ...lities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised...

Page 6: ...r outlet Dust PM2 5 sensor Inside the air inlet left side Page 6 15 17 Model name Production no Air inlets Front Side Power supply cord Air outlet Power supply plug Main Removable Parts Pre filter Pag...

Page 7: ...me cases an odour may be sensed even when the lamp is green If the odour bothers you switch to manual airflow rate and select a high airflow rate Page 10 The ambient odour level in the first minute af...

Page 8: ...nsmission range is approx 6m straight line Remote controller FAN MODE button Press to cycle between FAN settings and MODEs Page 10 12 ON OFF button Press to turn the power ON or OFF Page 10 ON OFF but...

Page 9: ...is not harmful to your health This product cannot eliminate the toxic substances in tobacco smoke carbon monoxide etc Do not use in the following places Places exposed to direct sunlight Decline in th...

Page 10: ...k face same direction Catch About the battery Keep batteries out of reach of children In the event that batteries are swallowed seek the immediate attention of a medical professional To avoid possible...

Page 11: ...eep hours To quickly eliminate odours from a room it is recommended that the FAN setting be set to Standard or above otherwise deodorising capacity is reduced Turbo The ambient air is quickly purified...

Page 12: ...justed automatically when the unit is running in a MODE Remote controller Press Each press cycles between the MODE lamps green ECONO ANTI POLLEN AUTO FAN Unit Press Each press cycles between the MODE...

Page 13: ...immediately after the unit was turned on Power saving mode Monitoring mode FAN setting switches automatically between Quiet and Low Streamer OFF The fan starts and stops periodically Dust and odours...

Page 14: ...ugged when Child proof lock is active Child proof lock is turned off The Child proof lock lamp orange lights up when the function is active Adjusting Indicator Lamp Brightness Indicator lamp brightnes...

Page 15: ...Note It is recommended that the streamer be set to Regular as deodorising capacity is reduced when set to Low Settings are remembered even if the unit is unplugged Blinking Lit up When you want to tur...

Page 16: ...to change the sensitivity To set sensitivity High Select the FAN lamp Turbo The sensor is highly receptive Setting at time of purchase The sensor is slightly receptive Standard Turbo Low High Normal L...

Page 17: ...N lamp Quiet will remain lit up To turn Monitoring mode ON Turn on the ECONO MODE lamp To turn Monitoring mode OFF Turn off the ECONO MODE lamp Setting at time of purchase ON OFF Setting is indicated...

Page 18: ...artial breakage of the filter may result Do not apply heavy force Partial breakage damage of the filter may result Removing Grip the indent in the pre filter and pull 1 Grip either end of the pre filt...

Page 19: ...nit is used daily in a home where 5 cigarettes are smoked a day the filter should be replaced about every 10 years Calculation based on testing method of Japan Electrical Manufacturers Association JEM...

Page 20: ...bly may cause damage 2 1 Connector Hook 2 Push in the left side of the streamer unit so the right side comes out You will hear a catching sound 3 Remove the streamer unit 4 Attach the new streamer uni...

Page 21: ...of the dust collection filter made of polyester and polypropylene Maintenance When Not Using the Unit for Long Time Periods 1 Remove the power supply plug 2 Clean the parts Page 17 18 In particular co...

Page 22: ...These lamps may blink if the unit is operated without a part attached If all parts are attached An electrical component is faulty Contact the place of purchase If one or more components are not attach...

Page 23: ...ust PM2 5 sensor Q Can the dust collection filter be cleaned A No Do not attempt to clean it with a vacuum cleaner or water Reduced performance of the dust collection filter may result Replace it if d...

Page 24: ...264V Unit will not operate Is the streamer unit cover attached If it is not attached the safety switch will engage and the unit cannot operate Install the streamer unit cover properly and attempt oper...

Page 25: ...17 Clean these parts After cleaning the unit will return to normal operation a short while after being turned on The PM2 5 INDICATOR lamp remain red purple or brown There is an odour but the odour sen...

Page 26: ...s the air outlet or an air inlet blocked If they are not blocked the fan motor is faulty Contact the place of purchase Other Phenomenon Check points The fan stops midway through unit operation When th...

Page 27: ...Weight kg 6 8 Power supply cord length m 1 8 These specification values are applicable to both 50Hz 220 240V and 60Hz 220 230V Even when the power is off approx 1W of power is consumed to run the mic...

Page 28: ...3P629501 4 2020 08 17 For manufacturing use only 3P629480 15 F...