background image

7

Names of Parts and Operations

Preparation Before Operation

Read First

Operating/Indicator panel

FAN/MODE button

Press to cycle between FAN settings 

and MODEs.  

 

Page 9-11

ON/OFF button

Press to turn the power ON or OFF. 

 

Page 9

1

Positioning the unit

Before installation, peel off the 

tape fixing the power supply 

cord to the bottom of the unit 

and draw out the power supply 

cord.

Power supply cord

Tape (blue)

Pointers for good positioning

• Choose a position from where airfl ow can reach all areas of the room.

Place on a stable surface. If the unit is placed on an unstable

surface, vibrations from the unit may be amplifi ed.

• If you fi nd that interference from the power circuit inside the unit

or cables causes interference on your TV screen or static noise
to be emitted from nearby radios or stereos, move the unit to at

least 2m away from the device.
Keep cordless phones and radio-controlled clocks away from the

unit also.

Attention

• To avoid staining of walls, position the unit in accordance with

the positioning measurements in the illustration. However, note
that since this unit draws in dirty air, certain types of wall may be

stained even if the measurements are adhered to.

In such cases, make sure to maintain suffi cient distance
between the unit and the wall.

When used for a long period of time in the same location, the

fl oor and surrounding walls may get stained as air is drawn into

air inlets near the base of the unit. It is recommended to clean
the unit periodically.

At least 100cm 

away from ceiling

At least 30cm 

away from wall

Air fl ow

At least 10cm 

away from wall

At least 30cm 

away from wall

Accessories

Operation manual ....... 1

01_EN_3P484757-1D.indd   7

10/1/2018   11:37:09 AM

Summary of Contents for MC40YPVM

Page 1: ...for purchasing this air puri er Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep the operation manual in a sa...

Page 2: ...olling PM2 5 These results were obtained in a 32m airtight space They are not demonstrable effects in customer environments Does not take into account in ow of new particles from outdoors owing to ven...

Page 3: ...dvanced Settings Setting Dust PM2 5 Sensor Sensitivity 12 Operation Using the Air Purifying Operation 9 Changing the Airflow Rate 9 Maintenance Maintenance 13 Replacing the Streamer Unit 15 Separately...

Page 4: ...g may result if the power supply plug is not firmly inserted Periodically wipe dust off the power supply plug with a dry cloth If the unit is not to be used for an extended period of time unplug the p...

Page 5: ...safety Children should be supervised to ensure that they do not play with the appliance Persons who are heavily intoxicated or have taken sleep medication should not operate the unit An electric shock...

Page 6: ...nside the air inlet left side Page 6 12 13 Model name Production no Air inlets Front Side Power supply cord Air outlet Power supply plug Main Removable Parts Pre filter Page 13 Outflow grille Page 13...

Page 7: ...rst minute after the unit is plugged in serves as the reference level upon which the sensitivity of the odour sensor is determined Insert the power supply plug when the air is clean odour free Odour s...

Page 8: ...tatic noise to be emitted from nearby radios or stereos move the unit to at least 2m away from the device Keep cordless phones and radio controlled clocks away from the unit also Attention To avoid st...

Page 9: ...Places with high levels of electromagnetic waves such as near an electromagnetic cooker speakers etc The unit may not function correctly Places exposed to soot conductive dust released by candles arom...

Page 10: ...dard or above otherwise deodorising capacity is reduced Turbo The ambient air is quickly purified using a large airflow Recommended for use while you are cleaning up a room Using the Air Purifying Ope...

Page 11: ...comparison to AUTO FAN MODE approx 9 2Wh power consumption in ECONO MODE approx 6 5Wh is approx 2 7Wh lower Test conditions operation in 10m2 area over 1 hour Assuming 1 cigarette was smoked immediate...

Page 12: ...r switching to the desired brightness press and select FAN setting and MODE of operation again Note This function is useful if the lamps bother you during sleep hours etc The ON OFF lamp does not turn...

Page 13: ...vity High Select the FAN lamp Turbo The sensor is highly receptive Setting at time of purchase The sensor is slightly receptive Standard Turbo Low High Normal Low To set sensitivity Low Select the FAN...

Page 14: ...rtial breakage of the filter may result Do not apply heavy force Partial breakage damage of the filter may result Removing Grip the indent in the pre filter and pull 1 Grip either end of the pre filte...

Page 15: ...it is used daily in a home where 5 cigarettes are smoked a day the filter should be replaced about every 10 years Calculation based on testing method of Japan Electrical Manufacturers Association JEM1...

Page 16: ...ly may cause damage 2 1 Connector Hook 2 Push in the left side of the streamer unit so the right side comes out You will hear a catching sound 3 Remove the streamer unit 4 Attach the new streamer unit...

Page 17: ...f the dust collection filter made of polyester and polypropylene Maintenance When Not Using the Unit for Long Time Periods 1 Remove the power supply plug 2 Clean the parts Page 13 14 In particular com...

Page 18: ...blink if the unit is operated without a part attached If all parts are attached An electrical component is faulty Contact the place of purchase If one or more components are not attached Remove the po...

Page 19: ...ust PM2 5 sensor Q Can the dust collection filter be cleaned A No Do not attempt to clean it with a vacuum cleaner or water Reduced performance of the dust collection filter may result Replace it if d...

Page 20: ...hile the streamer is operating the streamer unit will emit a hissing sound when conducting streamer discharge Depending on usage conditions the sound may fall in volume or change to a crackling whirri...

Page 21: ...a dry cotton bud or similar Page 13 Is the pre filter dirty Page 13 Clean these parts After cleaning the unit will return to normal operation a short while after being turned on The PM2 5 INDICATOR l...

Page 22: ...is being emitted Is the air outlet or an air inlet blocked If they are not blocked the fan motor is faulty Contact the place of purchase Other Phenomenon Check points The fan stops midway through uni...

Page 23: ...Weight kg 6 8 Power supply cord length m 1 8 These specification values are applicable to both 50Hz 220 240V and 60Hz 220 230V Even when the power is off approx 1W of power is consumed to run the micr...

Page 24: ...3P629501 3 2020 08 17 For manufacturing use only 3P629480 14 F...