(4)Defrosting Interval Automatic Changing Function
What is the Defrosting Interval Automatic Changing Function?
This is a function to measure the time required for defrosting operation with the "long timer"and,
according to the measurement, changes intervals of the defrosting operation. If a lapse of time after
turning OFF the power supply is less than 48 hours, the intervals of defrosting operation immediately
before turning OFF the power supply and elapsed time after the completion of defrosting operation
will be maintained. If a lapse of time after turning OFF the power supply is 48 hours or more, the
intervals of defrosting operation will be reset to the default value of 6 hours and the elapsed time
after the completion of defrosting operation will be reset to zero, respectively.
*
Caution
If the defrosting operation is performed according to any timer other than the long timer (e.g. short
timer or out-range timer), the defrosting operation counter will be reset to zero.
Conditions to use the Defrosting Interval Automatic Changing Function:
In order to use the defrosting interval automatic changing function, the following conditions should be
both satisfied.
¡
The defrosting interval automatic changing function is set to "ON" while in optional function
setting mode.
For details of the optional function setting, refer to information on page 19.
¡
The set temperature falls within the range of -2.0˚C
≦
+6.0˚C.
Details of Defrosting Interval Automatic Changing Function
To make the interval shorter:
If defrosting operation for a period of 40 minutes or more is performed consecutively two times or
defrosting operation for a period of 60 minutes or more is performed once, make the defrosting
operation interval shorter by 1 step with the "long timer".
Example:
・
6-hour interval before change
→
3-hour interval after change
・
12-hour interval before change
→
9-hour interval after change
To make the interval longer:
If defrosting operation for a period of 20 minutes or less is performed consecutively two times,
make the defrosting operation interval longer by 1 step with the "long timer".
Example:
・
3-hour interval before change
→
6-hour interval after change
・
9-hour interval before change
→
12-hour interval after change
Resetting of Contents of Defrosting Interval Automatic Changing Function
If a lapse of time after turning OFF the power supply is 48 hours or more, the intervals of defrosting
operation will be reset to the default value of 6 hours and the elapsed time after the completion of
defrosting operation will be reset to zero, respectively.
Procedure for counting a period of time during when the power supply is kept OFF
The period of time during when the power supply is kept OFF is counted in increments of 30 minutes.
Example: When a lapse of time after the completion of defrosting operation is 5 hours and 29
minutes and the interval of defrosting operation is set to 6 hours, if the power supply is turned OFF
once and ON again after a lapse of 47 hours and 59 minutes, counting of a period of time will be
restarted by taking the lapse of time as 5 hours (discarding the time less than 30 minutes) to start
defrosting operation 1 hour after the power supply is turned ON.
P001-028̲S/G-A4 英(LEX10E-A18A) 2006.04.21 20:17 ページ 10
https://daikin-p.ru
Summary of Contents for LXE10E-A18A
Page 30: ...15 APPENDIX 15 1 Refrigerant piping diagram 29 https daikin p ru ...
Page 33: ...32 https daikin p ru ...
Page 38: ...37 1 部品名称 1 1 庫外側 q レヒートコイル電磁弁 Trans FRESH RSV DSV BSV HSV ESV ISV 1 https daikin p ru ...
Page 39: ...38 1 2 庫内側 1 3 2 q レヒートコイル w USDAレセプタクル e パソコンポートレセプタクル https daikin p ru ...
Page 61: ...60 CA装置取付位置例 庫内側 Trans FRESH ASS Y A4 A5 CABLES W MOUNTING BOX q https daikin p ru ...
Page 62: ...15 付図 15 1 配管系統図 61 https daikin p ru ...
Page 65: ...64 https daikin p ru ...
Page 69: ...Parts related with the unit outside 庫外関連部品 68 TR05 09A https daikin p ru ...
Page 73: ...Parts related with refrigerant piping outside 庫外冷媒配管関連部品 72 TR05 09A https daikin p ru ...
Page 77: ...Parts related with the unit inside 庫内関連部品 76 TR05 09A https daikin p ru ...
Page 81: ...Parts related with refrigerant piping inside 庫内冷媒配管関連部品 80 TR05 09A https daikin p ru ...
Page 91: ...Control box コントローラボックス 90 TR05 09A https daikin p ru ...
Page 92: ... 91 TR05 09A Control box コントローラボックス https daikin p ru ...
Page 95: ...Parts related with name plate 銘板関連 94 TR05 09A https daikin p ru ...
Page 96: ...Parts related with name plate 銘板関連 95 TR05 09A https daikin p ru ...
Page 99: ...Parts related with option 1 Recorder box オプション関連部品1 レコーダボックス 98 TR05 09A https daikin p ru ...
Page 105: ...Storage for power cable ケーブル収納 104 TR05 09A https daikin p ru ...
Page 107: ...Parts related with option 4 TRANS FLESH オプション関連部品4 トランス フレッシュ 106 TR05 09A https daikin p ru ...
Page 119: ...MEMO https daikin p ru ...