4 User interface
Operation manual
11
LMSEY1A09/13 + LMSEY2A19/25
Daikin LMS
4P728169-1A – 2023.03
CtL
Control menu
Pro
Display probes menu
HcP
HACCP menu
CnF
Configuration menu
ALM
Alarms menu
PSd
Service menu
ESC
Exit the menu loop
Note:
To return to the standard display, go to "ESC" and press the
PROGRAM (c) button.
INFORMATION
If no button is pressed, the terminal will return to the
standard display after 7 seconds.
4.3.3
Parameters
Name
Description
Default
Min.
Max.
UoM
Menu
(a)
/5
Unit of measure:
▪ 0: °C
▪ 1: °F
0
0
1
●
Pro
/6
Display decimal point:
▪ 0: Yes
▪ 1: No
0
0
1
●
Pro
/t1
Display on user terminal:
▪ 0: not configured
▪ 1: value of S1
▪ 2: value of S2
▪ 3: value of S3
▪ 4: value of S4
▪ 5: value of S1H
▪ 6 to 8: not available
▪ 9: control probe
▪ 10: virtual probe
▪ 11 to 14: not available
▪ 15: current control setpoint
9
0
15
●
Pro
/t2
Display on remote display:
▪ 0 to 15, see /t1 (above)
0
0
15
●
Pro
Ad
Delay time for high and low temp. alarms (AH, AL)
120
0
240
min
●
ALM
Add
High temp. alarm bypass time for door open
5
1
240
min
●
ALM
AH
Relative high temperature alarm threshold
0
0
555/
999
∆ °C/°F
●
ALM
AL
Relative low temperature alarm threshold
0
0
200/
360
∆ °C/°F
●
ALM
Eco
Eco mode status:
▪ 0 OFF
▪ 1 ON
1
0
1
●
dir
Fr
SW version of the controller (read only)
r.04
0
0
dir
H11
BMS serial port configuration (stop bits and parity):
▪ 0: 1 stop bit, no parity
▪ 1: 2 stop bits, no parity
▪ 2: 1 stop bit, even parity
▪ 3: 2 stop bits, even parity
▪ 4: 1 stop bit, odd parity
▪ 5: 2 stop bits, odd parity
●
CnF
HAn
Number of type HA alarms (read-only)
0
0
6
●
PSd
Hb
Buzzer:
▪ 0: disabled
▪ 1: enabled
1
0
1
●
CnF
HFn
Number of type HF alarms (read-only)
0
0
6
●
PSd
Summary of Contents for LMSEY1A09AVM01
Page 124: ...2 124 LMSEY1A09 13 LMSEY2A19 25 Daikin LMS 4P728169 1A 2023 03 12 m3...
Page 125: ...2 125 LMSEY1A09 13 LMSEY2A19 25 Daikin LMS 4P728169 1A 2023 03 R290 R290...
Page 126: ...3 126 LMSEY1A09 13 LMSEY2A19 25 Daikin LMS 4P728169 1A 2023 03 10 50 V DC III 3 3 1 LMSEY R290...
Page 140: ...8 140 LMSEY1A09 13 LMSEY2A19 25 Daikin LMS 4P728169 1A 2023 03 7 3 4139...
Page 163: ......