Indoor Unit Installation Drawings
O N
OFF
50mm or more
from floor
D
Screws
(Field supply:
M3 × 20L)
E
Caulk
pipe hole
gap with
putty.
Cut thermal insulation pipe to an
appropriate length and wrap it with tape,
making sure that no gap is left in the
insulation pipe’s cut line.
Wrap the insulation
pipe with the
finishing tape from
bottom to top.
Before screwing the remote
controller holder to the wall, make
sure that control signals are
properly received by indoor unit.
Remote
controller
holder
Wireless
remote
controller
Space for
installation
work Min.
(200mm)
Space for
installation
work Min.
(200mm)
Mounting plate
A
Screws
(Field supply:
M4 × 25L)
50mm or more
from walls
There should be no space
between ceiling and the unit.
Space for installation work
Min. (200mm)
Space for installation work
Min. (200mm)
The mounting plate
should be installed
on a wall which can
support the weight
of the indoor unit.
Air filters
Hold the recessed
parts of the frame
and unhook the four
claws.
B Photocatalytic
deodorizing filter
C Air purifying filter
B Photocatalytic
deodorizing filter or
C Air purifying filter