22
Troubleshooting
7.2
Error codes and flashing sequences
Flashing code
Meaning
Solution
Short orange
flashing
Radio transmission/
attempting to transmit/
data transmission
Wait until the transmission is
completed.
1x long green
lighting
Transmission
confirmed
Continue operation.
1x long red
lighting
Transmission/
operation failed or duty
cycle limit is reached
Try again (see „7.1 Duty
Short orange
flashing (every
10 seconds)
Connection mode
active
Enter the last four numbers
of the device serial number
Fast orange
flashing
Connection mode
of both accessories
active (connecting)
Wait for confirmation of the
accessory LED.
6x long red
flashing
Accessory defective
Contact your reseller.
1x orange and 1
x green lighting
Test LED
After the test LED has
stopped, you can continue.