EDUS04-924A
Specifications
Room Air Conditioners H-Series
5
3. Specifications
3.1
Cooling Only -
60
Hz,
208 - 230 V
The data are based on the conditions shown in the table below.
Model
Indoor Unit
FTXS30HVJU
FTXS36HVJU
Outdoor Unit
RKS30HVJU
RKS36HVJU
Capacity
Rated (Min. ~ Max.)
kW
8.8 (3.0 ~ 8.8)
10.2-10.5 (3.0 ~ 10.2-10.5)
Btu/h
30,000 (10,200 ~ 30,000)
35,000-36,000 (10,200 ~ 35,000-36,000)
kcal/h
7,570 (2,580 ~ 7,570)
8,770-9,030 (2,580 ~ 8,770-9,030)
Running Current (Rated)
A
13.6-12.2
19.4-18.8
Power Consumption Rated (Min. ~ Max.)
W
2,800 (620 ~ 2,800)
4,000-4,300 (620 ~ 4,000-4,300)
Power Factor (Rated)
%
99.0-99.8
99.1-99.4
COP (Rated)
W/W
3.14 (4.84 ~ 3.14)
2.55-2.44 (4.84 ~ 2.55-2.44)
EER (Rated)
Btu/h·W
10.71 (16.45 ~ 10.71)
8.75-8.37 (16.45 ~ 8.75-8.37)
Piping
Connections
Liquid
in. (mm)
3/8
(9.5)
3/8
(9.5)
Gas
in. (mm)
5/8 (15.8)
5/8 (15.8)
Drain
in. (mm)
11/16 (17.5)
11/16 (17.5)
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Max. Interunit Piping Length
ft (m)
98.4 (30)
98.4 (30)
Max. Interunit Height Difference
ft (m)
65.6 (20)
65.6 (20)
Chargeless
ft (m)
32 (10)
32 (10)
Amount of Additional Charge of Refrigerant
oz/ft (g/m)
0.55 (16)
0.55 (16)
Indoor Unit
FTXS30HVJU
FTXS36HVJU
Front Panel Color
White
White
Airflow Rate
H
m³/min
(cfm)
20.0 (706)
21.8 (770)
M
17.3 (611)
18.0 (635)
L
14.7 (519)
14.7 (519)
SL
13.4 (473)
13.4 (473)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
64
64
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.38-0.34
0.38-0.34
Power Consumption (Rated)
W
77
77
Power Factor (Rated)
%
97.4-98.5
97.4-98.5
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H × W × D)
in. (mm)
13-3/8 × 47-1/4 × 9-7/16 (340 x 1200 x 240)
13-3/8 × 47-1/4 × 9-7/16 (340 x 1200 x 240)
Packaged Dimensions (H × W × D)
in. (mm)
12-13/16 × 51-9/16 × 16-7/8 (325 x 1310 x 429)
12-13/16 × 51-9/16 × 16-7/8 (325 x 1310 x 429)
Weight
Lbs (kg)
38 (17)
38 (17)
Gross Weight
Lbs (kg)
51 (23)
51 (23)
Operation
Sound
H / M / L / SL
dB(A)
47 / 45 / 40 / 37
49 / 45 / 40 / 37
Sound Power
dB(A)
63
65
Outdoor Unit
RKS30HVJU
RKS36HVJU
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC63HXD
2YC63HXD
Motor Output
W
2,030
2,030
Refrigerant Oil
Type
FVC50K
FVC50K
Charge
oz (kg)
25.5 (0.8)
25.5 (0.8)
Refrigerant
Type
R-410A
R-410A
Charge
Lbs (kg)
6.17 (2.8)
6.17 (2.8)
Airflow Rate
HH
m³/min
(cfm)
81.2 (2,867)
81.2 (2,867)
H
74.4 (2,627)
74.4 (2,627)
SL
65.6 (2,316)
65.6 (2,316)
Fan
Type
Propeller
Propeller
Motor Output
W
200
200
Running Current (Rated)
A
13.22-11.86
19.02-18.46
Power Consumption (Rated)
W
2,723
3,923-4,223
Power Factor (Rated)
%
99.0-99.8
99.2-99.5
Starting Current
A
18.9
19.4
Dimensions (H × W × D)
in. (mm)
38-15/16 × 37 × 12-5/8 (989 x 940 x 321)
38-15/16 × 37 × 12-5/8 (989 x 940 x 321)
Packaged Dimensions (H × W × D)
in. (mm)
44-1/8 × 38 × 15-1/4 (1121 x 965 x 387)
44-1/8 × 38 × 15-1/4 (1121 x 965 x 387)
Weight
Lbs (kg)
178 (81)
178 (81)
Gross Weight
Lbs (kg)
198 (90)
198 (90)
Operation
Sound
H / SL
dB(A)
54 / 51
54 / 51
Sound Power
H
dB(A)
68
68
Drawing No.
3D072241
3D072242
Cooling
Piping Length
Conversion Formulae
Indoor :80°FDB(27°CDB), 67°FWB(19.4°CWB),
Outdoor ; 95°FDB( 35°CDB) / 75°FWB( 24°CWB)
25 ft (7.5 m)
kcal/h = kW × 860 / Btu/h = kW × 3412 cfm
= m³/min × 35.3
Summary of Contents for H-Series
Page 1: ...EDUS04 924A H Series Cooling Only Heat Pump...
Page 50: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 49...
Page 51: ...Operation Manual Safety Considerations EDUS04 924A 50 Room Air Conditioners H Series...
Page 52: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 51...
Page 53: ...Operation Manual Safety Considerations EDUS04 924A 52 Room Air Conditioners H Series...
Page 54: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 53...
Page 55: ...Operation Manual Safety Considerations EDUS04 924A 54 Room Air Conditioners H Series...
Page 56: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 55...
Page 57: ...Operation Manual Safety Considerations EDUS04 924A 56 Room Air Conditioners H Series...
Page 58: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 57...
Page 59: ...Operation Manual Safety Considerations EDUS04 924A 58 Room Air Conditioners H Series...
Page 60: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 59...
Page 61: ...Operation Manual Safety Considerations EDUS04 924A 60 Room Air Conditioners H Series...
Page 63: ...Operation Manual Safety Considerations EDUS04 924A 62 Room Air Conditioners H Series...
Page 64: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 63...
Page 65: ...Operation Manual Safety Considerations EDUS04 924A 64 Room Air Conditioners H Series...
Page 66: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 65...
Page 67: ...Operation Manual Safety Considerations EDUS04 924A 66 Room Air Conditioners H Series...
Page 68: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 67...
Page 69: ...Operation Manual Safety Considerations EDUS04 924A 68 Room Air Conditioners H Series...
Page 70: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 69...
Page 71: ...Operation Manual Safety Considerations EDUS04 924A 70 Room Air Conditioners H Series...
Page 72: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 71...
Page 73: ...Operation Manual Safety Considerations EDUS04 924A 72 Room Air Conditioners H Series...
Page 74: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 73...
Page 75: ...Operation Manual Safety Considerations EDUS04 924A 74 Room Air Conditioners H Series...
Page 76: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 75...
Page 77: ...Operation Manual Safety Considerations EDUS04 924A 76 Room Air Conditioners H Series...
Page 78: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 77...
Page 79: ...Operation Manual Safety Considerations EDUS04 924A 78 Room Air Conditioners H Series...
Page 80: ...EDUS04 924A Operation Manual Safety Considerations Room Air Conditioners H Series 79...
Page 100: ...EDUS04 924A Optional Accessories Room Air Conditioners H Series 99...
Page 101: ...Optional Accessories EDUS04 924A 100 Room Air Conditioners H Series 3P248024 2...