![Daikin fxzq20mve Installation Manual Download Page 9](http://html.mh-extra.com/html/daikin/fxzq20mve/fxzq20mve_installation-manual_2460224009.webp)
8
English
(1-2)
Refer to the paper pattern for installation (5) for ceiling opening dimension.
Consult the builder or carpenter for details.
• The center of the ceiling opening is indicated on the paper pattern for installation.
The center of the unit is indicated on the paper pattern for installation.
• Fix the paper pattern to the unit with screws (6) (×4).
<Ceiling work>
(1-3)
Adjust the unit to the right position for installation.
(Refer to
4.PREPARATIONS BEFORE INSTALLATION-(1)
)
(1-4)
Check the unit is horizontally level.
• The indoor unit is equipped with a built-in drain
pump and float switch. Verify that it is level by using
a water level or a waterfilled vinyl tube.
CAUTION
If the unit is tilted against condensate flow, the float
switch may malfunction and cause water to drip.
(1-5)
Remove the washer fixing plate (7) used for preventing the washer from falling and tighten the upper nut.
(1-6)
Remove the paper pattern for installation (5).
(2) For existing ceilings
(2-1)
Install the indoor unit temporarily.
• Attach the hanger bracket to the suspension bolt. Be sure to fix it securely by using a nut and
washer (3) from the upper and lower sides of the hanger bracket.
The washer fixing plate (7) will prevent the washer from falling.
(2-2)
Adjust the height and position of the unit.
(Refer to
4.PREPARATIONS BEFORE INSTALLATION-(1).
)
(2-3)
Perform steps (1-4), (1-5) in (1) For new ceilings.
Fig. 11
Fig. 12
Paper pattern for installation (5)
Screws (6)
(accessory)
Screws (6)
(accessory) [Installation of paper pattern for installation]
Fig. 9
(accessory)
Water level
Vinyl tube
[Maintaining horizontality]
Fig. 10
Nut
(Field supplied)
Washer (3) (accessory)
Hanger bracket
Tighten
(double nuts)
[Securing the hanger bracket]
Insert
(accessory)
Washer fixing plate (7)
[Securing the washer]
01_EN_3P184443-5S.fm Page 8 Friday, October 16, 2015 6:44 PM