![Daikin fxzq20mve Installation Manual Download Page 18](http://html.mh-extra.com/html/daikin/fxzq20mve/fxzq20mve_installation-manual_2460224018.webp)
English
17
CAUTION
• When clamping wiring, use the included clamping material to prevent outside pressure being exerted on
the wiring connections and clamp firmly. When doing the wiring, make sure the wiring is neat and does not
cause the control box lid to stick up, then close the cover firmly.
• When attaching the control box lid, make sure you do not pinch any wires.
• After all the wiring connections are done, fill in any gaps in the through holes with putty or insulation (procured locally) to prevent
small animals and insects from entering the unit from outside. (If any do get in, they could cause short circuits in the control box.)
• Outside the machine, separate the weak wiring (remote controller cord) and strong wiring (interunit,
ground, and other power wiring) at least 50 mm so that they do not pass through the same place together.
Proximity may cause electrical interference, malfunctions, and breakage.
REMOTE
CONTROL
TRANSMISSION
WIRING
FORCED
OFF
Power supply
wiring
Power supply
terminal block
Remote controller wiring
Terminal block for
remote controller (6P)
Control box lid
Remote controller and transmission wiring
Power supply wiring
Wiring diagram label
(Back side of control box lid)
Remove the
control box lid
(take off 2
screws)
Transmission wiring
How to connect terminal block (6P)
for remote controller and
transmission wiring
L
N
L
N
How to connect power supply
terminal block with ground wire (3P)
REMOTE
CONTROL
TRANSMISSION
WIRING
FORCED
OFF
Fig. 28
Sealing material (12)
Attach completely to
hole of wiring without
leaving any space
[(ex.) How to attach sealing materials]
Wiring to
outside
(Outside)
10~15mm
Wiring
(Inside)
Sealing
material(12)
Be sure to attach it to prevent the infiltration of
water as well as any insects and other small
creatures from the outside. Otherwise a
short-circuit may occur inside the control box.
10~15
mm
Be sure to clamp
wire sheath.
After securing the
clamp (4) to clamp material,
cut off any extra material
Be sure to clamp
wire sheath.
After securing the
clamp (4) to clamp
material, cut off
any extra material
After clamping
Clamp(4)(Small)
to wire sheath,
clamp the wire
sheath with
Clamp(4)(Big)
to clamp
material.
Clamp(4)
(Small)
Clamp
material
Note
Clamp
material
Clamp(4)
(Big)
Clamp(4)
(Big)
(accessory)
(accessory)
(accessory)
(accessory)
(accessory)
Note
Note
01_EN_3P184443-5S.fm Page 17 Friday, October 16, 2015 6:44 PM