![Daikin fxzq20mve Installation Manual Download Page 5](http://html.mh-extra.com/html/daikin/fxzq20mve/fxzq20mve_installation-manual_2460224005.webp)
4
English
2-3
OPTIONAL ACCESSORIES
• The optional decoration panel and remote controller are required for this indoor unit. (Refer to Table 1, 2)
Table 1
• These are two types of remote controllers: wired and wireless. Select a remote controller from Table 2
according to customer request and install in an appropriate place.
Table 2
NOTE
• If you wish to use a remote controller that is not listed in Table 2, select a suitable remote controller after
consulting catalogs and technical materials.
FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND
CHECK AFTER INSTALLATION IS FINISHED.
a. Items to be checked after completion of work
b. Items to be checked at time of delivery
Also review the “SAFETY PRECAUTIONS”
Unit model
Optional decoration panel
FXZQ20·25·32·40·50MVE
BYFQ60BW1
Color : White
Remote controller type
Cooling only type
Heat Pump type
Wired type
BRC1C61
Wireless type
BRC7E531W
BRC7E530W
Items to be checked
If not properly done, what is likely to occur
Check
Are the indoor and outdoor unit fixed firmly?
The units may drop, vibrate or make noise.
Is the outdoor unit fully installed?
The unit may malfunction or the components
burn out.
Is the gas leak test finished?
It may result in insufficient cooling.
Is the unit fully insulated?
Condensate water may drip.
Does drainage flow smoothly?
Condensate water may drip.
Does the power supply voltage correspond
to that shown on the name plate?
The unit may malfunction or the components
burn out.
Are wiring and piping correct?
The unit may malfunction or the components
burn out.
Is the unit safely grounded?
Dangerous at electric leakage.
Is wiring size according to specifications?
The unit may malfunction or the components
burn out.
Is something blocking the air outlet or inlet of
either the indoor or outdoor units?
It may result in insufficient cooling.
Are refrigerant piping length and additional
refrigerant charge noted down?
The refrigerant charge in the system is not
clear.
Items to be checked
Check
Are the control box lid, air filter, suction grille attached?
Did you explain about operations while showing the instruction manual to your customer?
Did you hand the instruction manual over to your customer?
01_EN_3P184443-5S.fm Page 4 Friday, October 16, 2015 6:44 PM