background image

1

Installation and

operation manual

FXYCP20K7V1

FXYCP40K7V1

FXYCP80K7V1

FXYCP25K7V1

FXYCP50K7V1

FXYCP125K7V1

FXYCP32K7V1

FXYCP63K7V1

Before installation ..................................................................... 1

Selecting installation site .......................................................... 2

Preparations before installation ............................................... 2

Indoor unit installation .............................................................. 3

Refrigerant piping work ............................................................ 3

Drain piping work ...................................................................... 4

Electric wiring work ................................................................... 5

Wiring example and how to set the remote controller ............. 5

Wiring example ......................................................................... 6

Installation of the decoration panel .......................................... 6

Test operation ........................................................................... 6

Maintenance ............................................................................. 7

page

VRV System air conditioners

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

BEFORE INSTALLATION

Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling
of soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.

Refer to the installation manual of the outdoor unit for items
not described in this manual.

Caution concerning new refrigerant series:

The connectable outdoor units must be RSX(Y)P-K or
RSEYP-K, the outdoor units designed exclusively for
R407C.

If outdoor units for R22 are connected, the system will not
work properly.

Precautions

Do not install or operate the unit in rooms mentioned below.

Places with mineral oil, or filled with oil vapour or spray like
in kitchens. (Plastic parts may deteriorate.)

Where corrosive gas like sulphurous gas exists. (Copper
tubing and brazed spots may corrode.)

Where volatile flammable gas like thinner or gasoline is used.

Where machines generating electromagnetic waves exist.
(Control system may malfunction.)

Where the air contains high levels of salt such as air near
the ocean and where voltage fluctuates a lot (e.g. in
factories). Also in vehicles or vessels.

When selecting the installation site, use the supplied paper
pattern for installation.

Washer for hanging

bracket

8 pcs.

for gas pipe

for liquid pipe

Insulation for fitting

1 each

Drain hose

1 pc.

Clamp

1 pc.

Paper pattern for

installation

1 pc.

Accessories

Check if the following accessories are included with your unit.

Other: installation and operation manual

Optional accessories

There are two types of remote controllers: wired and wireless.
Select a remote controller according to customers request
and install in an appropriate place.
Refer to catalogues and technical literature for selecting a
suitable remote controller.

Decoration panel.

Screws M5

For paper pattern

for installation

4 pcs.

Also used as packing

material

Summary of Contents for FXYCP20K7V1

Page 1: ...INSTALLATION AND OPERATION MANUAL System air conditioner FXYCP20K7V1 FXYCP25K7V1 FXYCP32K7V1 FXYCP40K7V1 FXYCP50K7V1 FXYCP63K7V1 FXYCP80K7V1 FXYCP125K7V1...

Page 2: ...es overholder f lgende standard er eller andet andre retningsgivende dokument er forudsat at disse anvendes i henhold til vore instrukser respektive utrustning r utf rd i verensst mmelse med och f lje...

Page 3: ...6 5 1 1 7 5 6 2 3 4 5 6 8 7 9 13 12 10 11 3 4 2 1 1 2 3 4 P 1 P 2 F 1 F 2 T 1 T 2 8 7 5 6 4 3 1 2 1 2 3 4 3 4 1 2 100 mm 1 9 8 5 6 10 11 12 1 2 7 13 1 3 6 4 5 2 1500 1500 1000 H 350 100 100 520 5 640...

Page 4: ...T1 T2 1 2 3 4 L N IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 P1 P2 P1 P2 1 3 5 2 4 IN D OUT D F1 F2 F1 F2 Control box...

Page 5: ...escribed in this manual Caution concerning new refrigerant series The connectable outdoor units must be RSX Y P K or RSEYP K the outdoor units designed exclusively for R407C If outdoor units for R22 a...

Page 6: ...parts are field supplied For other installation than standard installation contact your Daikin dealer for details Is the indoor unit fixed firmly The unit may drop vibrate or make noise Is the gas lea...

Page 7: ...efore installation 5 Check if the unit is horizontally levelled Do not install the unit tilted The indoor unit is equipped with a built in drain pump and float switch If the unit is tilted against con...

Page 8: ...additional force To ensure a downward slope of 1 100 install hanging bars every 1 to 1 5m If unifying multiple drain pipes install the pipes as shown in figure 9 Select converging drain pipes whose ga...

Page 9: ...bush A and clamp the wires along with other wires using clamp A untightening the clip of clamp A by pressing After the connection tighten clamp A as before Unit wiring and remote controller wiring Rem...

Page 10: ...sed control forced off and on off operation 1 Wire specifications and how to perform wiring Connect input from outside to terminals T1 and T2 of the terminal board remote controller to transmission wi...

Page 11: ...l on one side and open by pulling toward yourself while holding it up NOTE Do not let go of the suction grill when opening or closing it If released the grill will spring back closed 2 Remove the air...

Page 12: ...polishing powder nor liquid insecticide It may cause discolouring or warping Do not let the indoor unit get wet It may cause electric shock or fire Clean the air suction grill when it is closed DISPO...

Page 13: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWE09081 1...