background image

• Indoor Unit • 4-way blow ceiling suspended unit • FXUQ-A

1

1

• VRV Systems • Indoor Unit

2

1

Features

In

do

or

 U

ni

t

VR

Sy

st

em

s

FX

UQ

-A

4

-

w

a

b

lo

w

 

Ideal solution for commercial spaces with narrow or no false ceilings

Separate BEVQ box is no longer needed: the expansion valve is 
integrated in the indoor unit.

User friendly remote control with contemporary design

Low energy consumption thanks to DC fan motor and drain pump

Easy to use: all main functions directly accessible

Stylish unit blends easily with any interior, as the flaps close entirely 
when not in operation

Easy setup: clear graphical user interface for advanced menu 
settings

Improved comfort thanks to automatic air flow adjustment to required 
load

Optimise your air conditioning system by activating a series of energy 
saving functions (temperature range limit, setback function, off timer, 
…)

Individual flap control: one or more flaps can be easily closed via the 
wired remote controller (BRC1E52) in case you would refurbish or 
rearrange your interior

Keep track of your energy consumption with the kWh indication 
showing an indicative electricity consumption

Can be installed in both new and existing buildings

Set up to 3 independent schedules, so the user can easily change the 
schedule himself throughout the year (e.g. summer, winter, mid-
season)

Same outlook for all models (unified dimensions)

Real time clock with auto update to daylight saving time

Supports multiple languages (English, German, Dutch, Spanish, 
Italian, Portuguese, French, Greek, Russian, Turkish and Polish)

Air can be discharged in 5 different angles between 0 and 60º

Possibility to individually restrict menu functions

Air flow distribution for ceiling heights up to 3.5m without capacity 
loss

When a power failure occurs all settings remain stored up to 48 hours 
thanks to the built-in backup power

Standard drain pump with 500mm lift

Home leave operation maintains the indoor temperature at your 
specified comfort level during absence, thus saving energy

3 steps

standard

Summary of Contents for FXUQ-A

Page 1: ...Air Conditioning Technical Data 4 way blow ceiling suspended unit EEDEN13 204 FXUQ A ...

Page 2: ......

Page 3: ...lectrical data 5 Electrical Data 5 4 Safety device settings 6 Safety Device Settings 6 5 Options 7 Options 7 6 Capacity tables 8 Cooling Capacity Tables 8 Heating Capacity Tables 9 Capacity Correction Factor 10 7 Dimensional drawings 12 Dimensional Drawings 12 8 Piping diagrams 13 Piping Diagrams 13 9 Wiring diagrams 14 Wiring Diagrams Single Phase 14 10 Sound data 15 Sound Pressure Spectrum 15 ...

Page 4: ...flaps can be easily closed via the wired remote controller BRC1E52 in case you would refurbish or rearrange your interior Keep track of your energy consumption with the kWh indication showing an indicative electricity consumption Can be installed in both new and existing buildings Set up to 3 independent schedules so the user can easily change the schedule himself throughout the year e g summer wi...

Page 5: ...d unit Height mm 295 Width mm 1 026 Depth mm 1 016 Weight Unit kg 26 27 Packed unit kg 39 Heat exchanger Type Cross fin coil multi slit fins and HI XA tubes Length mm 2 413 Rows Quantity 3 Fin pitch mm 1 2 Passes Quantity 10 Face area m 0 330 Stages Quantity 10 Empty tubeplate hole Quantity 0 Fan Type Turbo fan Quantity 1 Air flow rate 50Hz Cooling High m min 22 5 31 0 Nom m min 19 5 26 0 Low m mi...

Page 6: ...voltage supplied to unit terminal is not below or above listed range limits 2 Maximum allowable voltage range variation between phases is 2 3 MCA MFA MCA 1 25 x FLA 4 MFA 4 x FLA 5 Next lower standard fuse rating minimum 16A 6 Select wire size based on the value of MCA 7 Instead of a fuse use a circuit breaker 2 2 Electrical Specifications FXUQ71A FXUQ100A Power supply Phase 1 Frequency Hz 50 60 V...

Page 7: ...3 1 3 VRV Systems Indoor Unit 5 Indoor Unit 4 way blow ceiling suspended unit FXUQ A 3 Electrical data 3 1 Electrical Data ...

Page 8: ... Indoor Unit 4 way blow ceiling suspended unit FXUQ A 1 4 VRV Systems Indoor Unit 6 4 Safety device settings 4 1 Safety Device Settings ...

Page 9: ...3 1 5 VRV Systems Indoor Unit 7 Indoor Unit 4 way blow ceiling suspended unit FXUQ A 5 Options 5 1 Options ...

Page 10: ...HO VLVWHPD OD FDSDFLGDG GH IXQFLRQDPLHQWR UHDO del equipo interior diferirá de la que se muestra en la tabla debido a los cambios de la temperatura de aire exterior y al factor de carga Nel caso in cui intervenissero dei cambiamenti nelle condizioni dovuti a requisiti di progettazione successivi alla selezione del sistema la capacità operativa effettiva delle apparecchiature interne sarà diversa d...

Page 11: ...GHELGR D ORV FDPELRV GH OD WHPSHUDWXUD GH DLUH H WHULRU DO IDFWRU GH FDUJD 1HO FDVR LQ FXL LQWHUYHQLVVHUR GHL FDPELDPHQWL QHOOH FRQGL LRQL GRYXWL D UHTXLVLWL GL SURJHWWD LRQH VXFFHVVLYL DOOD VHOH LRQH GHO VLVWHPD la capacità operativa effettiva delle apparecchiature interne sarà diversa da quella indicata in tabella a causa della diversa temperatura dell aria esterna e del fattore di carico ȈIJȘȞ ʌ...

Page 12: ...B 16 0 CWB 18 0 CWB 19 0 CWB 20 0 CWB 22 0 CWB 24 0 CWB 20 0 CDB 23 0 CDB 26 0 CDB 27 0 CDB 28 0 CDB 30 0 CDB 32 0 CDB FXUQ71 TC 0 675 0 702 0 762 0 784 0 804 0 836 0 859 SHF 1 149 1 164 1 110 1 088 1 072 1 061 1 046 FXUQ100 TC 0 678 0 707 0 770 0 795 0 813 0 839 0 862 SHF 1 144 1 159 1 105 1 082 1 069 1 060 1 049 FXUQ A 3D079901 Capacity correction factor Te 9 C ...

Page 13: ...B 16 0 CWB 18 0 CWB 19 0 CWB 20 0 CWB 22 0 CWB 24 0 CWB 20 0 CDB 23 0 CDB 26 0 CDB 27 0 CDB 28 0 CDB 30 0 CDB 32 0 CDB FXUQ71 TC 0 554 0 559 0 593 0 631 0 664 0 718 0 759 SHF 1 149 1 239 1 254 1 197 1 157 1 117 1 094 FXUQ100 TC 0 543 0 565 0 602 0 643 0 676 0 725 0 762 SHF 1 144 1 232 1 244 1 189 1 150 1 114 1 096 FXUQ A 3D079901 Capacity correction factor Te 11 C ...

Page 14: ... Indoor Unit 4 way blow ceiling suspended unit FXUQ A 1 7 VRV Systems Indoor Unit 12 7 Dimensional drawings 7 1 Dimensional Drawings ...

Page 15: ...3 1 8 VRV Systems Indoor Unit 13 Indoor Unit 4 way blow ceiling suspended unit FXUQ A 8 Piping diagrams 8 1 Piping Diagrams ...

Page 16: ... Indoor Unit 4 way blow ceiling suspended unit FXUQ A 1 9 VRV Systems Indoor Unit 14 9 Wiring diagrams 9 1 Wiring Diagrams Single Phase ...

Page 17: ...3 1 10 VRV Systems Indoor Unit 15 Indoor Unit 4 way blow ceiling suspended unit FXUQ A 10 Sound data 10 1 Sound Pressure Spectrum ...

Page 18: ......

Page 19: ...04 The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N V Daikin Europe N V has compiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy re liability or fitness for particular purpose of its content and the products and services presented therein Specif...

Reviews: