background image

Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product. 

Daikin units comply with the European regulations that
guarantee the safety of the product.

Pr

in

ted in B

elgium b

y L

annoo  (www.lannooprint.be)

, a company whose concer

n for

the environm

ont is set in the E

M

AS

 and IS

O 1

4001 systems. 

Responsibl

e E

ditor: 

D

aikin E

urope N.V

., Zandvoor

destraat 300,

 B

- 84

00 Oostende

The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy,
reliability or fitness for particular purpose of its content and the products and
services presented therein. Specifications are subject to change without
prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or
indirect damage,  in the broadest sense, arising from or related to the use
and/or interpretation of this publication. All content is copyrighted by Daikin
Europe N.V..

VRV

®

 products are not within the scope of the Eurovent

certification programme.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and
refrigerants has led to its close involvement in
environmental issues. For several years Daikin has
had the intension to become a leader in the provision
of products that have limited impact on the
environment. This challenge demands the eco design
and development of a wide range of products and an
energy management system, resulting in energy
conservation and a reduction of waste.

ISO14001 assures an effective environmental
management system in order to help protect human health
and the environment from the potential impact of our
activities, products and services and to assist in
maintaining and improving the quality of the environment.

Summary of Contents for FXNQ20MAVE

Page 1: ...technical data Concealed Floor Standing Unit FXNQ MAVE air conditioning systems...

Page 2: ...ications 60Hz 3 2 Safety device settings 4 3 Options 4 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 8 6 Dimensional drawing centre of gravity 10 Dimensiona...

Page 3: ...high W 15 15 25 25 35 35 Drive Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 35 0 35 0 35 0 38 0 39 0 40 0 Low dBA 32 0 32 0 32 0 33 0 34 0 35 0 Piping connections Liquid OD Typ...

Page 4: ...se a circuit breaker 1 3 Electrical Specifications 60Hz FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE Power Supply Name VE Phase 1 Frequency Hz 60 Voltage V 220 Current Minimum cir...

Page 5: ...3 Options 3D034529C FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA PC BOARD FUSE 250V 10A FAN MOTOR THERMAL PROTECTOR C OFF 135 10 ON 120 or less FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA F...

Page 6: ...NQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA CENTRALISED REMOTE CONTROL DCS302C51 UNIFIED ON OFF CONTROL DCS301C51 SCHEDULE TIMER DST301C51 FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA...

Page 7: ...31 0 1 9 1 6 2 3 1 8 2 6 2 0 2 8 2 1 3 0 2 1 3 1 2 0 3 2 1 9 33 0 1 9 1 6 2 3 1 8 2 6 2 0 2 8 2 1 3 0 2 1 3 1 2 0 3 1 1 9 35 0 1 9 1 6 2 3 1 8 2 6 2 0 2 8 2 1 3 0 2 1 3 0 2 0 3 1 1 9 37 0 1 9 1 6 2 3...

Page 8: ...31 0 3 8 3 0 4 5 3 4 5 2 3 8 5 6 3 9 6 0 4 0 6 2 3 8 6 4 3 7 33 0 3 8 3 0 4 5 3 4 5 2 3 8 5 6 3 9 6 0 4 0 6 1 3 8 6 3 3 6 35 0 3 8 3 0 4 5 3 4 5 2 3 8 5 6 3 9 5 9 4 0 6 0 3 8 6 2 3 6 37 0 3 8 3 0 4 5...

Page 9: ...3 0 3 0 2 8 3 0 2 2 3 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3...

Page 10: ...5 8 5 8 5 5 3 0 2 2 6 2 6 2 6 2 6 1 5 9 5 5 5 0 4 1 6 4 6 4 6 3 6 1 5 9 5 5 7 0 6 0 6 6 6 6 6 3 6 1 5 9 5 5 9 0 7 9 6 8 6 7 6 3 6 1 5 9 5 5 11 0 9 8 7 0 6 7 6 3 6 1 5 9 5 5 13 0 11 8 7 1 6 7 6 3 6 1 5...

Page 11: ...Description 1 Liquid pipe connection port 6 4 flare connection 2 Gas pipe connection port 12 7 flare connection 3 Drain pipe connection port O D 21 4 Switch box 5 Air filter FXNQ32 40MA 3D038864B 150...

Page 12: ...4 7 hole Total on right left 2 12x18 slot hole Hole for fixing to the floor Top plate 10 4 7 hole Total on front rear Hole for fixing to the floor 4 12x30 slot hole Hole for rear mounting NOTES 1 Loc...

Page 13: ...oor Standing Unit FXNQ MAVE VRV Systems Indoor Units 12 6 Dimensional drawing centre of gravity 6 2 Centre of gravity 3 6 FXNQ MA 4D034533B Model A FXNQ20MA 395 FXNQ25MA 395 FXNQ32MA 465 FXNQ40MA 465...

Page 14: ...or Units 13 Indoor Units Concealed Floor Standing Unit FXNQ MAVE 7 Piping diagram 3 7 FXNQ MA 4D034245A Heat exchanger Fan Filter Filter Electronic expansion valve Liquid pipe connection port Gas pipe...

Page 15: ...ontrol In details refer to the installation manual attached to the unit 3 Use copper conductors only Indoor unit R2T R3T Thermistor Coil A1P Printed circuit board T1R Transformer 220 240V 22V C1 Capac...

Page 16: ...pressure level dB 0 dB 0 0002 bar Scale 220V 240V H L H L A 35 32 37 34 C 39 37 41 39 220V 240V 1 5m 1 5m 0 1m Board Duct Field work Microphone Air discharge option NOTES 1 Over all dB B G N is alread...

Page 17: ...ns Power source 220 240V 220V 50 60Hz JIS standard 4 Location of microphone 5 Operating noise differs with operation and ambient conditions FXNQ63MA 4D034538A Approximate threshold hearing for continu...

Page 18: ...010 1 Open the lid of control panel both left and right 2 Remove screws both left and right 3 Push the knobs both left and right to the rear 4 Lift the front of the top plate 5 Lower the front panel t...

Page 19: ...ndoor Units 18 10 Installation 10 2 Service space 3 10 FXNQ MA 3P086154 1 4 A or more Maintenance area B or more 625 80 or more NOTE 1 Leave sufficient clearance for air inlet and maintenance Model A...

Page 20: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: