• VRV Systems • Indoor Units

5

• Indoor Units • Concealed Floor Standing Unit • FXNQ-MAVE

4

Control systems

3

4

Individual control systems

Centralised control systems

Others

4D034581A

FXNQ20MA

FXNQ25MA

FXNQ32MA

FXNQ40MA

FXNQ50MA

FXNQ63MA

WIRED REMOTE CONTROL

BRC1D52

INFRARED REMOTE CONTROL

Heat pump 

BRC4C62

Cooling only

BRC4C64

SIMPLIFIED REMOTE CONTROL

BRC2A51

REMOTE CONTROL FOR HOTEL USE

BRC3A61

FXNQ20MA

FXNQ25MA

FXNQ32MA

FXNQ40MA

FXNQ50MA

FXNQ63MA

CENTRALISED REMOTE CONTROL

DCS302C51

UNIFIED ON/OFF CONTROL

DCS301C51

SCHEDULE TIMER

DST301C51

FXNQ20MA

FXNQ25MA

FXNQ32MA

FXNQ40MA

FXNQ50MA

FXNQ63MA

WIRING ADAPTER 

KRP1B61

WIRING ADAPTER FOR ELECTRICAL APPENDICES (1)

KRP2A51

WIRING ADAPTER FOR ELECTRICAL APPENDICES (2)

KRP4A51

REMOTE SENSOR

KRCS01-1

ELECTRICAL BOX WITH EARTH TERMINAL (3 BLOCKS)

KJB311A

ELECTRICAL BOX WITH EARTH TERMINAL (2 BLOCKS)

KJB212A

NOISE FILTER (FOR ELECTROMAGNETIC INTERFACE USE ONLY)

KEK26-1A

EXTERNAL CONTROL ADAPTER FOR OUTDOOR UNITS (INSTALLATION ON INDOOR UNIT)

DTA104A61

Summary of Contents for FXNQ20MAVE

Page 1: ...technical data Concealed Floor Standing Unit FXNQ MAVE air conditioning systems...

Page 2: ...ications 60Hz 3 2 Safety device settings 4 3 Options 4 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 8 6 Dimensional drawing centre of gravity 10 Dimensiona...

Page 3: ...high W 15 15 25 25 35 35 Drive Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 35 0 35 0 35 0 38 0 39 0 40 0 Low dBA 32 0 32 0 32 0 33 0 34 0 35 0 Piping connections Liquid OD Typ...

Page 4: ...se a circuit breaker 1 3 Electrical Specifications 60Hz FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE Power Supply Name VE Phase 1 Frequency Hz 60 Voltage V 220 Current Minimum cir...

Page 5: ...3 Options 3D034529C FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA PC BOARD FUSE 250V 10A FAN MOTOR THERMAL PROTECTOR C OFF 135 10 ON 120 or less FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA F...

Page 6: ...NQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA CENTRALISED REMOTE CONTROL DCS302C51 UNIFIED ON OFF CONTROL DCS301C51 SCHEDULE TIMER DST301C51 FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA...

Page 7: ...31 0 1 9 1 6 2 3 1 8 2 6 2 0 2 8 2 1 3 0 2 1 3 1 2 0 3 2 1 9 33 0 1 9 1 6 2 3 1 8 2 6 2 0 2 8 2 1 3 0 2 1 3 1 2 0 3 1 1 9 35 0 1 9 1 6 2 3 1 8 2 6 2 0 2 8 2 1 3 0 2 1 3 0 2 0 3 1 1 9 37 0 1 9 1 6 2 3...

Page 8: ...31 0 3 8 3 0 4 5 3 4 5 2 3 8 5 6 3 9 6 0 4 0 6 2 3 8 6 4 3 7 33 0 3 8 3 0 4 5 3 4 5 2 3 8 5 6 3 9 6 0 4 0 6 1 3 8 6 3 3 6 35 0 3 8 3 0 4 5 3 4 5 2 3 8 5 6 3 9 5 9 4 0 6 0 3 8 6 2 3 6 37 0 3 8 3 0 4 5...

Page 9: ...3 0 3 0 2 8 3 0 2 2 3 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3...

Page 10: ...5 8 5 8 5 5 3 0 2 2 6 2 6 2 6 2 6 1 5 9 5 5 5 0 4 1 6 4 6 4 6 3 6 1 5 9 5 5 7 0 6 0 6 6 6 6 6 3 6 1 5 9 5 5 9 0 7 9 6 8 6 7 6 3 6 1 5 9 5 5 11 0 9 8 7 0 6 7 6 3 6 1 5 9 5 5 13 0 11 8 7 1 6 7 6 3 6 1 5...

Page 11: ...Description 1 Liquid pipe connection port 6 4 flare connection 2 Gas pipe connection port 12 7 flare connection 3 Drain pipe connection port O D 21 4 Switch box 5 Air filter FXNQ32 40MA 3D038864B 150...

Page 12: ...4 7 hole Total on right left 2 12x18 slot hole Hole for fixing to the floor Top plate 10 4 7 hole Total on front rear Hole for fixing to the floor 4 12x30 slot hole Hole for rear mounting NOTES 1 Loc...

Page 13: ...oor Standing Unit FXNQ MAVE VRV Systems Indoor Units 12 6 Dimensional drawing centre of gravity 6 2 Centre of gravity 3 6 FXNQ MA 4D034533B Model A FXNQ20MA 395 FXNQ25MA 395 FXNQ32MA 465 FXNQ40MA 465...

Page 14: ...or Units 13 Indoor Units Concealed Floor Standing Unit FXNQ MAVE 7 Piping diagram 3 7 FXNQ MA 4D034245A Heat exchanger Fan Filter Filter Electronic expansion valve Liquid pipe connection port Gas pipe...

Page 15: ...ontrol In details refer to the installation manual attached to the unit 3 Use copper conductors only Indoor unit R2T R3T Thermistor Coil A1P Printed circuit board T1R Transformer 220 240V 22V C1 Capac...

Page 16: ...pressure level dB 0 dB 0 0002 bar Scale 220V 240V H L H L A 35 32 37 34 C 39 37 41 39 220V 240V 1 5m 1 5m 0 1m Board Duct Field work Microphone Air discharge option NOTES 1 Over all dB B G N is alread...

Page 17: ...ns Power source 220 240V 220V 50 60Hz JIS standard 4 Location of microphone 5 Operating noise differs with operation and ambient conditions FXNQ63MA 4D034538A Approximate threshold hearing for continu...

Page 18: ...010 1 Open the lid of control panel both left and right 2 Remove screws both left and right 3 Push the knobs both left and right to the rear 4 Lift the front of the top plate 5 Lower the front panel t...

Page 19: ...ndoor Units 18 10 Installation 10 2 Service space 3 10 FXNQ MA 3P086154 1 4 A or more Maintenance area B or more 625 80 or more NOTE 1 Leave sufficient clearance for air inlet and maintenance Model A...

Page 20: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: