background image

11

CAUTION

• Be sure to attach the sealing material or putty (field supplied) 

to hole of wiring to prevent the infiltration of water as well as 
any insects and other small creatures from outside. Other-
wise a short-circuit may occur inside the electric parts box.

• When clamping the wires, be sure no pressure is applied to 

the wire connections by using the included clamping material 
to make appropriate clamps. Also, when wiring, make sure 
the lid on the electric parts box fits snugly by arranging the 
wires neatly and attaching the electric parts box lid firmly. 
When attaching the electric parts box lid, make sure no wires 
get caught in the edges. Pass wiring through the wiring 
through holes to prevent damage to them.

• Make sure the remote controller wiring, the wiring between 

the units, and other electrical wiring do not pass through the 
same locations outside of the unit, separating them by at 
least 1 15/16”, otherwise electrical noise (external static) 
could cause mistaken operation or breakage. 

NOTE

1.

Use round crimp-style terminals for connecting wires to the 
power supply terminal block. 

If unavailable, observe the following points when wiring.
• Do not connect wires of different gauge to the same 

power supply terminal.
(Looseness in the connection may cause overheating.)

• Use the specified electric wire. Connect the wire securely 

to the terminal. Lock the wire down without applying 
excessive force to the terminal. (Tightening torque: 
0.97ft.lbf ±10 %)

2. Tightening torque for the terminal screws.

• Use the correct screwdriver for tightening the terminal 

screws. If the blade of screwdriver is too small, the head 
of the screw might be damaged, and the screw will not be 
properly tightened.

• If the terminal screws are tightened too hard, screws 

might be damaged.

• Refer to the table below for the tightening torque of the 

terminal screws.

3. Do not connect wires of different gauge to the same ground-

ing terminal. Looseness in the connection may deteriorate 
protection.

4. Outside of the unit, keep transmission wiring at least 

1 15/16” away from power supply wiring. The equipment 
may malfunction if subjected to electrical (external) noise. 

5. For remote controller wiring, refer to the “INSTALLATION 

MANUAL OF REMOTE CONTROLLER” attached to the 
remote controller. 

6.

Never connect power supply wiring to the terminal 
block for remote controller wiring. A mistake of the sort 
could damage the entire system.

7. Use only specified wire and tightly connect wires to termi-

nals. Be careful wires do not place external stress on termi-
nals. Keep wiring in neat order and so as not to obstruct 
other equipment such as popping open the electric parts 
box lid. Make sure the lid closes tight. Incomplete connec-
tions could result in overheating, and in worse case, electric 
shock or fire.

10-2  WIRING EXAMPLE 

• Fit the power supply wiring of each unit with a switch and 

fuse as shown in the drawing.

COMPLETE SYSTEM EXAMPLE 

1. When using 1 remote controller for 1 indoor unit. 

(Normal operation)

2. For group control or use with 2 remote controllers

Summary of Contents for FXFQ12MVJU

Page 1: ...VJU FXFQ18MVJU FXFQ24MVJU FXFQ30MVJU FXFQ36MVJU SYSTEM Inverter Air Conditioners INSTALLATION MANUAL Read these instructions carefully before installation Keep this manual in a handy place for future...

Page 2: ...LATION 5 5 INSTALLATION PROCEDURES FOR FRESH AIR INTAKE DUCT CONNECTION 6 6 INDOOR UNIT INSTALLATION 6 7 REFRIGERANT PIPING WORK 7 8 DRAIN PIPING WORK 8 9 ELECTRIC WIRING WORK 10 10 WIRING EXAMPLE AND...

Page 3: ...esult in the equip ment falling and causing injuries Carry out the specified installation work after taking into account strong winds typhoons or earthquakes Improper installation work may result in t...

Page 4: ...ne of transport Leave the unit inside its packaging while moving until reach ing the installation site Where unpacking is unavoidable use a sling of soft material or protective plates together with a...

Page 5: ...t be sufficient enough to eliminate the noise 2 Ceiling height This indoor unit may be installed on ceilings up to 11 5 ft 30 36 13 8 ft in height Refer to the table 3 Air flow direction The below fig...

Page 6: ...rked on the paper pattern for instal lation Refer to it to check for points requiring reinforcing length in 4 PREPARATIONS BEFORE INSTALLA TION 1 Relation of ceiling opening to unit and suspension bol...

Page 7: ...nd a sunken insert sunken anchor or other field supplied parts for new ceilings to reinforce the ceiling to bear the weight of the unit Adjust clearance from the ceiling before proceeding further 5 IN...

Page 8: ...BEFORE INSTALLATION 1 3 Perform steps 4 5 in 6 1 For new ceilings 7 REFRIGERANT PIPING WORK 7 1 GENERAL INSTRUCTIONS For refrigerant piping of outdoor units see the installation man ual attached to t...

Page 9: ...unit Any exposed piping may cause condensation or burns if touched 7 4 Brazing referigerant piping Before brazing local refrigerant piping nitrogen gas shall be blown through the piping to expel air...

Page 10: ...r the operating capacity of the unit NOTE Drain piping connections Do not connect the drain piping directly to sewage pipes that smell of ammonia The ammonia in the sewage might enter the indoor unit...

Page 11: ...ax 3280 ft Total wiring length 6560 ft 2 Indoor unit Remote controller Max 1640 ft 10 WIRING EXAMPLE AND HOW TO SET THE REMOTE CONTROLLER 10 1 HOW TO CONNECT WIRINGS Methods of wiring power supply uni...

Page 12: ...he terminal Tightening torque 0 97ft lbf 10 2 Tightening torque for the terminal screws Use the correct screwdriver for tightening the terminal screws If the blade of screwdriver is too small the head...

Page 13: ...rystal display air filer signs to display the time to clean air filters Change the SECOND CODE NO according to Table 5 depending on the amount of dirt or dust in the room SECOND CODE NO is factory set...

Page 14: ...ON FOR SERVICING of the outdoor unit If any of the items in Table 6 are displayed there may be a problem with the wiring or power so check the wiring again Table 4 Remote control display Content Conce...

Page 15: ...14 MEMO...

Page 16: ...0403 HT 3PN01417 8U EM03A040B Daikin US Corporation 375 Park Avenue Suite 3308 New York NY 10152 www daikinac com info daikinac com...

Reviews: