Wiring diagram

8 - 1 Wiring diagram

3

8

FXAQ-MV

3D060858A

NOTES

1

In case of using central remote control, connect it to the unit in accordance with the attached instruction manual.

2

When connecting the input wires from outside, forced off or on/off control operation can be selected by remote control.
In details, refer to the installation manual attached to the unit.

3

Remote control model varies according to the combination system confirm enineering materials and catalogs, etc. before connecting.

4

Confirm the method of setting the selector switch (SS1, SS2) of wired remote control and ingrared rempte control by installation manual and 
engineering data, etc.

5

X24A is connected when the infrared remote control kit is being used.

Indoor unit

Y1E

Electronic expansion valve

Wired remote control

A1P

Printed circuit board

PC

Power Circuit

R1T

Thermistor (Air)

F1U

Fuse (

, 3A, 250V)

Receiver / display unit (attached to infrared remote control)

SS1

Selector switch (main/sub)

HAP

Light emitting diode 
(service monitor-green)

A2P

Printed circuit board

Connector for optional parts

A3P

Printed circuit board

R1T

Thermistor (Air)

M1F

Motor (indoor fan)

BS1

Push button (On/Off)

SS1

Selector switch (main/sub)

M1S

Motor (swing flap)

H1P

Light emitting diode (On-red)

Connector for optional parts

R1T

Thermistor (air)

H2P

Light emitting diode (timer-green)

X15A

Connector (float switch)

R2T

Thermistor (coil liquid pipe)

H3P

Light emitting diode (filter sign-red)

X35A

Connector (group control adapter)

R3T

Thermistor (coil gas pipe)

H4P

Light emitting diode (defrost-orange)

X38A

Connector (adapter for multi tenant)

X1M

Terminal block

SS1

Selector switch (Wireless adress set)

X2M

Terminal block

: Terminal

Colors:

RED:

Red

PRP:

Purple

ORG:

Orange

: Connector

BLK:

Black

GRN:

Green

: Connector

WHT:

White

BLU:

Blue

: Field wiring

YLW:

Yellow

PNK:

Pink

POWER SUPPLY

Control box

(indoor unit)

Input from outside note 3

Transmission wiring
Central remote control note 1

Note: 5

Receiver/Display unit

(Infrared remote control)

Wired remote control

Side

Front

Note: 5

,

Summary of Contents for FXAQ-MAVE9 Series

Page 1: ...Wall Mounted Unit FXAQ MAVE9 air conditioning systems technical data...

Page 2: ...fications 60Hz 3 2 Safety device settings 4 3 Options 4 4 Control systems 4 5 Capacity tables 5 Cooling capacity tables 5 Heating capacity tables 7 6 Dimensional drawing centre of gravity 9 Dimensiona...

Page 3: ...L9661M QCL9661M QCL9686M QCL9686M QCL9686M Output high W 40 40 40 43 43 43 Drive Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 35 0 36 0 37 0 39 0 42 0 46 0 Low dBA 29 0 29 0 29...

Page 4: ...ller than or equal to 4 x FLA Next lower standard fuse rating minimum 15A Select wire size based on the MCA Instead of a fuse use a circuit breaker 1 3 ELECTRICAL SPECIFICATIONS 60HZ FXAQ20MAVE9 FXAQ2...

Page 5: ...FXAQ32MV FXAQ40MV FXAQ50MV FXAQ63MV Wired remote control BRC1D52 Infrared remote control Heat pump BRC7E618 Cooling only BRC7E619 FXAQ20MV FXAQ25MV FXAQ32MV FXAQ40MV FXAQ50MV FXAQ63MV Remote control...

Page 6: ...1 8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 1 2 2 3 2 2 1 33 0 1 9 1 8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 1 2 2 3 1 2 1 35 0 1 9 1 8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 0 2 2 3 1 2 1 37 0 1 9 1 8 2 3 2 0 2 6 2...

Page 7: ...3 2 4 5 3 7 5 2 4 1 5 6 4 2 6 0 4 3 6 2 4 2 6 4 3 9 33 0 3 8 3 2 4 5 3 7 5 2 4 1 5 6 4 2 6 0 4 3 6 1 4 2 6 3 3 9 35 0 3 8 3 2 4 5 3 7 5 2 4 1 5 6 4 2 5 9 4 3 6 0 4 1 6 2 3 8 37 0 3 8 3 2 4 5 3 7 5 2 4...

Page 8: ...8 3 0 2 2 3 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3 0 2 8 15...

Page 9: ...5 3 0 2 2 6 2 6 2 6 2 6 1 5 9 5 5 5 0 4 1 6 4 6 4 6 3 6 1 5 9 5 5 7 0 6 0 6 6 6 6 6 3 6 1 5 9 5 5 9 0 7 9 6 8 6 7 6 3 6 1 5 9 5 5 11 0 9 8 7 0 6 7 6 3 6 1 5 9 5 5 13 0 11 8 7 1 6 7 6 3 6 1 5 9 5 5 15...

Page 10: ...nnection 5 Liquid pipe 6 4 Flare connection 6 Drain hose VP13 External dia 18 7 Grounding terminal M4 8 Right side pipe connection hole 9 Left side pipe connection hole FXAQ40 50MV 3D038539B Approx 40...

Page 11: ...r more required space 2 500 or more For installation in high places Filter part Filter part Name plate Note 2 Approx 475 Approx 460 Approx 415 Piping and wiring intake Mounting location NOTES 1 Name p...

Page 12: ...ping diagram 3 7 FXAQ MV DU220 602J Liquid pipe connection port Filter Filter Electronic expansion valve Fan Gas pipe connection port Refrigerant flow Cooling Heating Heat exchanger Piping connection...

Page 13: ...Fuse 3A 250V Receiver display unit attached to infrared remote control SS1 Selector switch main sub HAP Light emitting diode service monitor green A2P Printed circuit board Connector for optional par...

Page 14: ...ic pressure 0 dB 20 Pa 2 Measuring place anechoic chamber 3 Operating noise differs with operation and ambient conditions Data were not available at the time of publication Model Sound pressure level...

Page 15: ...LOW Approximate treshold hearing for continuous noise Ocatve band sound pressure level dB 0dB 0 0002 bar Scale Mode Hi Low A 36 0 29 0 C 40 5 34 0 Mike 1m 1m NOTES 1 Over all dB B G N is already recti...

Page 16: ...LOW Approximate treshold hearing for continuous noise Ocatve band sound pressure level dB 0dB 0 0002 bar Scale Mode Hi Low A 42 0 36 0 C 44 0 39 0 Mike 1m 1m NOTES 1 Over all dB B G N is already recti...

Page 17: ...m or bigger When directly connecting a hard vinyl chloride pipe joint nominal diameter 13mm to the drain hose connected to the indoor unit i e for embedded piping etc use a commercially available hard...

Page 18: ...ible within the allowable limit Refer to the installation manual of the outdoor unit Keep the indoor and outdoor units power cable and transmission wiring at least 1 m from TVs and radios to prevent d...

Page 19: ...Indoor Units Wall Mounted Unit FXAQ MAVE9 VRV Systems Indoor Units 18 10 Installation 10 2 Service space 3 10...

Page 20: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: