background image

• VRV

®

 Systems • Indoor Units

13

• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE

8

Wiring diagram

8 - 1 Wiring diagram

FXAQ-MA

3D034206C

220-240V

~

50Hz

220V

~

60Hz

Power supply

Control Box

(Indoor unit)

Front

Side

Receiver/display unit

(Infrared remote control)

Note 5

Note 5

Note 2

Note 1

Input from outside

Transmission wiring

Central remote control

Wired remote control

NOTES

1

In case of using central remote control, connect it to the unit in accordance with the attached installation manual.

2

When connecting the input wires from outside, forced off or on/off control operation can be selected by remote control. In details, refer to the installation manual atached the unit..

3

Remote control model varies according to the combination system. Confirm engineering data and catalogs, etc.. before connecting.

4

Confirm the method of setting the selector switch (SS1, SS2) of wired remote control and infrared remote control by installation manual and engineering data, etc.

5

X24A is connected when the infrared remote control kit is being used.

Indoor Unit
A1P

Printed circuit board

Y1E

Electronic expansion valve

SS1

Selector switch (Main/sub)

F1U

Fuse (

 , 3A, 250V)

PC

Power Circuit

SS2

Selector switch (Wireless adress set)

HAP

Light emitting diode (Service monitor-green)

Receiver/display unit (Attached to infrared remote control)

M1F

Motor (Indoor fan)

A2P

Printed circuit board

Wired remote control

M1S

Motor (Swing flap)

A3P

Printed circuit board

R1T

Thermistor (Air)

R1T

Thermistor (Air)

BS1

Push button (On/off)

SS1

Selector switch (Main/sub)

R2T

Thermistor (Coil liquid pipe)

H1P

Light emitting dide (On-red)

R3T

Thermistor (Coil gas pipe)

H2P

Light emitting diode (Timer green)

Connector for optional parts

X1M

Terminal block (Control)

H3P

Light emitting diode (Filter sign-red)

X15A

Connector (Float switch)

X2M

Terminal block (Power)

H4P

Light emitting diode (Defrost-orange)

X35A

Connector (Group control adapter)

COLORS  :  BLK : Black 

PNK : Pink

 

  BLU : Blue 

RED : Red

 

  BRN : Brown 

WHT : White

 

  GRN : Green 

YLW : Yellow

 

  ORG : Orange 

: Terminal
: Connector
: Shows short circuit connector
: Field wiring

,

Summary of Contents for FXAQ-MAVE

Page 1: ...technical data Wall Mounted Unit FXAQ MAVE air conditioning systems EEDDE08 204 2e...

Page 2: ...l Specifications 3 2 Safety device settings 4 3 Options 4 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 8 6 Dimensional drawing centre of gravity 10 Dimensi...

Page 3: ...Model QCL9661M QCL9661M QCL9661M QCL9686M QCL9686M QCL9686M Output high W 40 40 40 43 43 43 Drive Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 35 0 36 0 37 0 39 0 42 0 46 0 Lo...

Page 4: ...amps FLA A 0 20 0 30 0 30 0 30 0 30 0 50 Voltage range Minimum V 10 Maximum V 10 Notes Voltage range units are suitable for use on electrical systems where voltage supplied to unit terminals is not b...

Page 5: ...E VRV Systems Indoor Units 4 2 Safety device settings 3 Options FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA PC BOARD FUSE 250V 3A 4D034906F FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ6...

Page 6: ...p BRC7E618 Cooling only BRC7E619 FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA CENTRALISED REMOTE CONTROL DCS302C51 UNIFIED ON OFF CONTROL DCS301B51 SCHEDULE TIMER DST301B51 FXAQ20MA FXAQ25MA...

Page 7: ...8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 1 2 2 3 2 2 1 33 0 1 9 1 8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 1 2 2 3 1 2 1 35 0 1 9 1 8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 0 2 2 3 1 2 1 37 0 1 9 1 8 2 3 2 0 2 6 2 2...

Page 8: ...2 4 5 3 7 5 2 4 1 5 6 4 2 6 0 4 3 6 2 4 2 6 4 3 9 33 0 3 8 3 2 4 5 3 7 5 2 4 1 5 6 4 2 6 0 4 3 6 1 4 2 6 3 3 9 35 0 3 8 3 2 4 5 3 7 5 2 4 1 5 6 4 2 5 9 4 3 6 0 4 1 6 2 3 8 37 0 3 8 3 2 4 5 3 7 5 2 4 1...

Page 9: ...3 0 2 2 3 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3 0 2 8 15 0...

Page 10: ...3 0 2 2 6 2 6 2 6 2 6 1 5 9 5 5 5 0 4 1 6 4 6 4 6 3 6 1 5 9 5 5 7 0 6 0 6 6 6 6 6 3 6 1 5 9 5 5 9 0 7 9 6 8 6 7 6 3 6 1 5 9 5 5 11 0 9 8 7 0 6 7 6 3 6 1 5 9 5 5 13 0 11 8 7 1 6 7 6 3 6 1 5 9 5 5 15 0...

Page 11: ...ection 5 Liquid pipe 6 4 Flare connection 6 Drain hose VP13 External dia 18 7 Grounding terminal M4 8 Right side pipe connection hole 9 Left side pipe connection hole FXAQ40 50MA 3D038539B Approx 400...

Page 12: ...more required space 2 500 or more For installation in high places Filter part Filter part Name plate Note 2 Approx 475 Approx 460 Approx 415 Piping and wiring intake Mounting location NOTES 1 Name pla...

Page 13: ...Piping diagram FXAQ MA DU220 602J Liquid pipe connection port Filter Filter Electronic expansion valve Fan Gas pipe connection port Refrigerant flow Cooling Heating Heat exchanger Piping connection di...

Page 14: ...lation manual and engineering data etc 5 X24A is connected when the infrared remote control kit is being used Indoor Unit A1P Printed circuit board Y1E Electronic expansion valve SS1 Selector switch M...

Page 15: ...W Approximate treshold hearing for continuous noise Ocatve band sound pressure level dB 0dB 0 0002 bar Scale Mode Hi Low A 36 0 29 0 C 40 5 34 0 Mike 1m 1m NOTES 1 Over all dB B G N is already rectifi...

Page 16: ...W Approximate treshold hearing for continuous noise Ocatve band sound pressure level dB 0dB 0 0002 bar Scale Mode Hi Low A 42 0 36 0 C 44 0 39 0 Mike 1m 1m NOTES 1 Over all dB B G N is already rectifi...

Page 17: ...e within the allowable limit Refer to the installation manual of the outdoor unit Keep the indoor and outdoor units power cable and transmission wiring at least 1 m from TVs and radios to prevent dist...

Page 18: ...ted therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage In the broadest sense arising from or related...

Reviews: