6

Dimensional drawing & centre of gravity

6 - 1 Dimensional drawing

FXAQ20,25,32MA

3D034903C

Approx. 400

232
230

290

50 or more

(Required space)

Dimensions for 

full open front panel

Piping direction

Piping direction

626

795

155

125

Outside line

ø 80 hole

ø 80 hole

107

60

14.5

44

105

44

62

98

Piping direction

50 or more
(Required space)

120 or less

30 or more (required space)

90 or more (required space)

2500 or more

For installation

in high places

(Filter part)

(Filter part)

(Flexible tube part)

Name plate Note 2

Approx. 475

Approx. 460

Approx. 415

Approx. 290

(Piping and wiring intake)

Mounting location

NOTES

1

Name plate location: right side surface of casing

2

In case of using an infrared remote control, this position will be 
a signal receiver. Refer to the drawing of an infrared remote 
control in detail.

Nr

Part name

Description

1

Front panel

2

Front grill

3

Air  outlet

4

Gas pipe

ø 12.7 Flare connection

5

Liquid pipe

ø 6.4 Flare connection

6

Drain hose

VP13 (External dia. ø18)

7

Grounding terminal

M4

8

Right side pipe connection hole

9

Left side pipe connection hole

FXAQ40,50MA

3D038539B

Approx. 400

232

230

290

50 or more

(Required space)

Dimensions for 

full open front panel

Piping direction

Piping direction

894

1,050

155

125

Outside line

ø 80 hole

ø 80 hole

104

60

14.5

44

105

44

52

98

Piping direction

50 or more
(Required space)

120 or less

30 or more (required space)

90 or more (required space)

2,500 or more

For installation

in high places

(Filter part)

(Filter part) (Flexible tube part)

Name plate Note 2

Approx. 475

Approx. 460

Approx. 415

Approx. 290

(Piping and wiring intake)

Mounting location

NOTES

1

Name plate location: right side surface of casing.

2

In case of using an infrared remote control, this position will be 
a signal receiver. Refer to the drawing of the infrared remote 
control in detail.

Nr

Part name

Description

1

Front panel

2

Front grill

3

Air  outlet

4

Gas pipe

ø 12.7 Flare connection

5

Liquid pipe

ø 6.4 Flare connection

6

Drain hose

VP13 (External dia. ø 18)

7

Grounding terminal

M4

8

Right side pipe connection hole

9

Left side pipe connection hole

Summary of Contents for FXAQ-MAVE

Page 1: ...technical data Wall Mounted Unit FXAQ MAVE air conditioning systems EEDDE08 204 2e...

Page 2: ...l Specifications 3 2 Safety device settings 4 3 Options 4 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 8 6 Dimensional drawing centre of gravity 10 Dimensi...

Page 3: ...Model QCL9661M QCL9661M QCL9661M QCL9686M QCL9686M QCL9686M Output high W 40 40 40 43 43 43 Drive Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 35 0 36 0 37 0 39 0 42 0 46 0 Lo...

Page 4: ...amps FLA A 0 20 0 30 0 30 0 30 0 30 0 50 Voltage range Minimum V 10 Maximum V 10 Notes Voltage range units are suitable for use on electrical systems where voltage supplied to unit terminals is not b...

Page 5: ...E VRV Systems Indoor Units 4 2 Safety device settings 3 Options FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA PC BOARD FUSE 250V 3A 4D034906F FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ6...

Page 6: ...p BRC7E618 Cooling only BRC7E619 FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA CENTRALISED REMOTE CONTROL DCS302C51 UNIFIED ON OFF CONTROL DCS301B51 SCHEDULE TIMER DST301B51 FXAQ20MA FXAQ25MA...

Page 7: ...8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 1 2 2 3 2 2 1 33 0 1 9 1 8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 1 2 2 3 1 2 1 35 0 1 9 1 8 2 3 2 0 2 6 2 2 2 8 2 2 3 0 2 2 3 0 2 2 3 1 2 1 37 0 1 9 1 8 2 3 2 0 2 6 2 2...

Page 8: ...2 4 5 3 7 5 2 4 1 5 6 4 2 6 0 4 3 6 2 4 2 6 4 3 9 33 0 3 8 3 2 4 5 3 7 5 2 4 1 5 6 4 2 6 0 4 3 6 1 4 2 6 3 3 9 35 0 3 8 3 2 4 5 3 7 5 2 4 1 5 6 4 2 5 9 4 3 6 0 4 1 6 2 3 8 37 0 3 8 3 2 4 5 3 7 5 2 4 1...

Page 9: ...3 0 2 2 3 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3 0 2 8 15 0...

Page 10: ...3 0 2 2 6 2 6 2 6 2 6 1 5 9 5 5 5 0 4 1 6 4 6 4 6 3 6 1 5 9 5 5 7 0 6 0 6 6 6 6 6 3 6 1 5 9 5 5 9 0 7 9 6 8 6 7 6 3 6 1 5 9 5 5 11 0 9 8 7 0 6 7 6 3 6 1 5 9 5 5 13 0 11 8 7 1 6 7 6 3 6 1 5 9 5 5 15 0...

Page 11: ...ection 5 Liquid pipe 6 4 Flare connection 6 Drain hose VP13 External dia 18 7 Grounding terminal M4 8 Right side pipe connection hole 9 Left side pipe connection hole FXAQ40 50MA 3D038539B Approx 400...

Page 12: ...more required space 2 500 or more For installation in high places Filter part Filter part Name plate Note 2 Approx 475 Approx 460 Approx 415 Piping and wiring intake Mounting location NOTES 1 Name pla...

Page 13: ...Piping diagram FXAQ MA DU220 602J Liquid pipe connection port Filter Filter Electronic expansion valve Fan Gas pipe connection port Refrigerant flow Cooling Heating Heat exchanger Piping connection di...

Page 14: ...lation manual and engineering data etc 5 X24A is connected when the infrared remote control kit is being used Indoor Unit A1P Printed circuit board Y1E Electronic expansion valve SS1 Selector switch M...

Page 15: ...W Approximate treshold hearing for continuous noise Ocatve band sound pressure level dB 0dB 0 0002 bar Scale Mode Hi Low A 36 0 29 0 C 40 5 34 0 Mike 1m 1m NOTES 1 Over all dB B G N is already rectifi...

Page 16: ...W Approximate treshold hearing for continuous noise Ocatve band sound pressure level dB 0dB 0 0002 bar Scale Mode Hi Low A 42 0 36 0 C 44 0 39 0 Mike 1m 1m NOTES 1 Over all dB B G N is already rectifi...

Page 17: ...e within the allowable limit Refer to the installation manual of the outdoor unit Keep the indoor and outdoor units power cable and transmission wiring at least 1 m from TVs and radios to prevent dist...

Page 18: ...ted therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage In the broadest sense arising from or related...

Reviews: