background image

FWC

Fan coil units
4PW64525-1B – 2014.03

Installation manual

2

Precautions for installation

1.3.1. Meaning of warnings and symbols

Warnings in this manual are classified according to their severity and 
probability of happening.

Some types of danger are represented by special symbols:

Precautions for installation

Precautions for installation

2

Precautions for installation

All instructions described in this manual shall be carried out by a 
licensed installer.
Install the unit according to the instructions in the included 
documentation and the manuals of the additional equipment (e.g. 
controller). Improper installation could result in electric shock, short-
circuit, leaks, fire or other damage to the equipment.
Be sure to wear adequate personal protection equipment (protection 
gloves, safety glasses) when performing installation, maintenance or 
service to the unit.
If not sure of installation procedures or operation of the unit, always 
contact your local DAIKIN dealer for advice and information.

Prepare the installation of the fan coil unit

Prepare the installation of the fan coil unit

3

Prepare the installation of the fan coil 
unit

Prepare the installation of the fan coil unit

3.1.

Check that you have all optional equipment

Mandatory equipment per fan coil unit

: Each fan coil unit must be 

equipped with one of these decoration panels. 

Mandatory equipment:

 Each fan coil unit must be connected to at 

least one of the listed controllers.

(a) 

For installation of these options, an installation box option kit may be required. See 

option list in the data book for more information.

Optional Equipment to extend the life of your product

Danger

: Indicates an imminently hazardous situation 

which, if not avoided, will result in death or serious injury.

Warning

: Indicates a potentially hazardous situation which, 

if not avoided, could result in death or serious injury.

Caution

: Indicates a potentially hazardous situation which, 

if not avoided, may result in minor or moderate injury.

Notice

: Indicates situations that may result in damage to 

equipment or property. 

Information

: This symbol identifies useful information, but 

no hazardous situation warnings.

Electric current

Danger of burning or scalding

Danger: electric shock

Switch off all power supply before removing the control box 
cover or before making any connections or touching 
electrical parts.
To avoid electric shock, be sure to disconnect the power 
supply 1 minute or more before servicing the electrical 
parts. Even after 1 minute, always measure the voltage at 
the terminals of main circuit capacitors or electrical parts 
and, before touching, be sure that those voltages are 
50 V DC or less.

Danger: high temperature

Do not touch the water piping or internal parts during and 
immediately after operation. The piping and internal parts 
may be hot or cold depending on the working condition of 
the unit.
Your hand may get burned or frostbitten if you touch the 
piping or internal parts. To avoid injury, give the piping and 
internal parts time to return to normal temperature or, if you 
must touch them, be sure to wear adequate protective 
gloves.

Decoration panel

Identification code

Description

Decoration panel - 
standard

BYCQ140CW1

Decoration panel for 
the fan coil unit with 
normal sealing 
colour.

Decoration panel - 
white

BYCQ140CW1W

Decoration panel for 
the fan coil unit with 
white sealings.

Controllers

Identification code

Description

Electronic remote 
controller - wireless 
(cooling and heating)

BRC7F532F

Wireless remote 
controller to control 
each fan coil unit 
independently with 
cooling and heating 
functionality.

Electronic remote 
controller - wireless 
(cooling only)

BRC7F533F

Wireless remote 
controller to control 
each fan coil unit 
independently with 
cooling functionality 
only.

Electronic remote 
controller - wired

BRC315D7

 (a)

Wired remote 
controller to control 
each fan coil unit with 
cooling and heating 
functionality.

Central remote 
controller

DCS302CA51

 (a)

Remote controller for 
centralized control of 
all connected units.

Intelligent touch 
controller

DCS601C51C

 (a)

Advanced remote 
controller for 
centralized control of 
all connected units.

Unified ON/OFF 
controller

DCS301BA51

 (a)

Remote controller to 
switch all connected 
units ON or OFF.

Air handling 
options

Identification code

Description

Sealing member of 
air discharge outlet

KDBHQ55C140

Blocking parts to 
close one or more air 
outlets of the fan coil 
unit.

Long-life 
replacement filter

KAFP551K160

High quality filter.

Fresh air intake kit

KDDQ55C140

Kit which can be 
connected to the 
ventilation system in 
order to supply fresh 
air to the fan coil unit.

Summary of Contents for FWC06B7TV1B

Page 1: ...INSTALLATION MANUAL Fan coil units Cover Cover Type numbers FWC06B7TV1B FWC07B7TV1B FWC08B7TV1B FWC09B7TV1B FWC06B7FV1B FWC07B7FV1B FWC08B7FV1B FWC09B7FV1B...

Page 2: ...mm F1 F2 P1 P2 T1 T2 k i j j i g 1x 1x 8x 4x 1x 1x 1x 1x 1x 1x 1x FWC_T 2x FWC_F 4x FWC_T 2x FWC_F 4x FWC_T 2x FWC_F 4x a b c d e h i j k l m f g n a f b d c e 4 mm c e b A A A A a a a b 2500 1500 29...

Page 3: ...em A e com o parecer positivo de B de acordo com o Certificado C 09 A B C 10 Bem rk som anf rt i A og positivt vurderet af B i henhold til Certifikat C 11 Information enligt A och godk nts av B enligt...

Page 4: ...o install and operate the associated products and or optional equipment refer to the relevant catalogues technical literature or product manuals for those products The original documentation is writte...

Page 5: ...r scalding Danger electric shock Switch off all power supply before removing the control box cover or before making any connections or touching electrical parts To avoid electric shock be sure to disc...

Page 6: ...mperature is 5 C Q the maximum water temperature is 50 C 2 pipe fan coil units and 70 C 4 pipe fan coil units Q be sure to install components in the field piping that can withstand the water pressure...

Page 7: ...directions Select the air flow directions best suited for the room and point of installation For air discharge in 2 or 3 directions it is necessary to make field settings by means of the remote contr...

Page 8: ...he hanger bracket as illustrated in figure 15 Securing the hanger bracket 2 Fix the paper pattern for installation delivered with the unit For new ceilings only Q The paper pattern for installation co...

Page 9: ...onnection Connect the water inlet and outlet connections of the fan coil unit to the water piping as illustrated in figure 5 Connecting the water piping In case the optional valve is used refer to the...

Page 10: ...transmission wiring and other wiring Failure to observe this guideline may result in malfunction due to electrical noise Q For the remote controller wiring refer to the installation manual of the remo...

Page 11: ...Pull the cables i j inside through the remote controller and unit transmission cables intake h 3 Strip the wires to the recommended length 4 Connect the remote controller wires to P1 P2 terminals of t...

Page 12: ...ment refer to the installation manual which is delivered with the optional equipment and take into account the remarks mentioned in the table below a Ceiling slab b Hanger bracket c Drain raising pipe...

Page 13: ...n manual delivered with the option EKRP1C11 but refer to the installation manual of options EKMV2 and EKMV3 instead EKFCMBCB7 Optional PCB for Modbus connection Option Description Remark Danger electr...

Page 14: ...N dealer Test operation before installing decoration panel 1 Open the water inlet valve s 2 Open the water outlet valve s 3 Set to cooling operation with the remote controller and start operation by p...

Page 15: ...t brush and neutral detergent and dry thoroughly See figure 21 Cleaning the suction grill 6 Attach the air filter to the suction grill by hanging it to the projected portion above the suction grill Pr...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...P1 L N L a N P2 F1 F2 T1 T2 P1 L N L N P2 F1 F2 T1 T2 P1 L N L N P2 P1 P2 P1 P2 P1 P2 P1 P2 F1 F2 T1 T2 P1 L N L N P2 F1 F2 T1 T2 c b 100 0 675 a a a a 710 840 860 910 860 860 910 950 20 35 20 35 780...

Page 20: ...Copyright 2010 Daikin 4PW64525 1B 2014 03 Cover Rear Cover Rear...