background image

En

gl

is

1

 

OUT

IN

OUT

IN

OUTLINE AND DIMENSIONS

Indoor Unit: Ceiling Concealed Fan Coil Unit G Series

All dimensions are in mm

All dimensions are in mm

FWC03/04/06G

 

Dimension

Model

KA

KB

KC

KD

KE

02G

657

630

494

414

470

03/04G

801

774

638

558

614

06G

901

874

738

658

714

08/10G

1289

1264

1127

1049

1103

FWC08/10G

WATER OUT 
(3/4" BSPT FEMALE THREAD ADAPTOR)

WATER IN 
(3/4" BSPT FEMALE THREAD ADAPTOR)

MOUNTING HOLE 
(4 X 10.0 X 16.0)

CONDENSATE DRAIN (R3/4")

1

9

8

267

KD

KC

187

43

104

161

219

461

132

KE

38

66

110

18

18

16

143

38

27

30

82

148

251

FWC02G

WATER OUT 
(3/4" BSPT FEMALE THREAD ADAPTOR)

WATER IN 
(3/4" BSPT FEMALE THREAD ADAPTOR)

MOUNTING HOLE 
(4 X 10.0 X 16.0)

CONDENSATE DRAIN (R3/4")

198

267

KD

KC

187

43

104

161

219

461

132

KB

KA

KE

38

26

66

110

18

18

38

27

82

148

251

143

16

OUT

IN

WATER OUT 
(3/4" BSPT FEMALE THREAD ADAPTOR)

WATER IN 
(3/4" BSPT FEMALE THREAD ADAPTOR)

MOUNTING HOLE 
(4 X 10.0 X 16.0)

CONDENSATE DRAIN (R3/4")

198

267

KD

KC

187

43

104

161

219

461

132

KB

KA

KE

38

66

110

18

18

16

143

27

30

82

148

251

All dimensions are in mm

KB

KA

30

26

26

38

Summary of Contents for FWC02G

Page 1: ...FAN COIL UNIT G SERIES IM CCGW 0821 5 DAIKIN Part Number R08019045598 Installation Manual Chilled Water Fan Coil Unit English MODELS FWC02G FWC03G FWC04G FWC06G FWC08G FWC10G FWC12G FWC14G FWC16G FWC...

Page 2: ...6 0 CONDENSATE DRAIN R3 4 198 267 KD KC 187 43 104 161 219 461 132 KE 38 66 110 18 18 16 143 38 27 30 82 148 251 FWC02G WATER OUT 3 4 BSPT FEMALE THREADADAPTOR WATER IN 3 4 BSPT FEMALE THREADADAPTOR M...

Page 3: ...74 155 18 16 248 119 143 328 363 25 660 175 109 KC KB 49 37 75 KA OUT IN 198 KE 187 43 104 18 143 27 161 219 251 18 148 132 110 38 26 267 KC 38 KB KA 16 59 WATER OUT 1 BSPT FEMALE THREADADAPTOR 142 WA...

Page 4: ...78 1300 1354 1392 1298 14G 1142 1116 953 877 929 930 836 16 18G 1280 1254 1091 1015 1067 1068 974 20G 1420 1394 1231 1155 1207 1208 1114 FWC14 16 18 20G 12 203 59 12 KG 59 KF 24 363 KE KD KC KB KA 43...

Page 5: ...or use in room where mineral oil oil vapour or oil steam exist this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction When the unit is used in kitchen keep f...

Page 6: ...ong to withstand the weight 300mm or more 300mm or more Can be smaller than 300mm if ceiling is removable Floor 2300mm or more Ceiling Insulation material field supply 300mm or more Air outlet side Se...

Page 7: ...se contaminated or damaged pipe and fitting for installation Some main fitting components are needed in the system to enhance the capacity and ease of service such as gate valve balancing valve 2 way...

Page 8: ...08 230V 60Hz TH 220 240V 50Hz or 208 230V 60Hz 220 240V 50Hz or 208 230V 60Hz TH FSC FSC FL FM FH N FL FM FH N L N L N L N FL Fan Low FM Fan Medium FH Fan High N Neutral FSC Fan Speed Controller X1 X2...

Page 9: ...er means for disconnection having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the relevant local and national legislation 7 2 8 1 2 2 8 2 2 8 0 1 2 3...

Page 10: ...g wires to the power supply terminal block Connect the wires by matching to the indication on terminal block Refer to the wiring diagram attached on the unit Operating Limits Thermal carrier Water Ent...

Page 11: ...ion guide for such unit The installation of fan coil unit may vary according to the type of outdoor unit Installation must be done by qualified personnel who is familiar with this type of product Ensu...

Page 12: ...the Adaptor Holder INTERCHANGEABLE HEAT EXCHANGER PIPING DIRECTION GUIDE LINE The simulation below is based on FCU FWC G Unit From right piping direction to left piping direction To perform this simu...

Page 13: ...ow the Hairpin move out and not touching the Side Panel MOVE UPWARDS STEP 7 While holding Heat Exchanger gently move out the Heat Exchanger Distributor from the Side Panel Please be aware of the relea...

Page 14: ...pe is at the same side with the Adaptor Holder STEP 14 The changing of Heat Exchanger Pipe Direction is completed STEP 10 Then gently pull the Side Panel outwards to allow the Hairpin side of the Heat...

Page 15: ...it 4 Switch off unit and call local dealer serviceman If the fault persists please call your local dealer serviceman SERVICE AND MAINTENANCE CAUTION Avoid direct contact of any coil treatment cleaners...

Page 16: ...nato ku Tokyo 108 0075 Japan http www daikin com global Lot 10 Jalan Perusahaan 8 Kawasan Perusahaan Pekan Banting 42700 Banting Selangor D E Malaysia The manufacturer reserves the right to revise any...

Reviews: