background image

Table of Contents

Installation manual

2

C FVXM25~50A

Split system air conditioners

3P477070-2M – 2021.09

Table of Contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 Specific installer safety instructions

2

3 About the box

3

3.1

Indoor unit .................................................................................

3

3.1.1

To remove the accessories from the indoor unit.........

3

4 About the unit

4

4.1

About the wireless LAN .............................................................

4

4.1.1

Precautions when using the wireless LAN..................

4

4.1.2

Basic parameters ........................................................

4

4.1.3

Setting the wireless LAN.............................................

4

5 Unit installation

4

5.1

Preparing the installation site ....................................................

4

5.1.1

Installation site requirements of the indoor unit ..........

4

5.2

Opening the indoor unit .............................................................

4

5.2.1

To remove the front panel...........................................

4

5.2.2

To remove the front grille ............................................

5

5.2.3

To open the terminal block and remove the electrical
wiring box cover ..........................................................

5

5.3

Mounting the indoor unit............................................................

5

5.3.1

To install the indoor unit..............................................

5

5.3.2

To drill a wall hole .......................................................

8

5.3.3

To remove the slit portions..........................................

8

5.3.4

To provide drainage ....................................................

8

6 Piping installation

9

6.1

Preparing refrigerant piping .......................................................

9

6.1.1

Refrigerant piping requirements..................................

9

6.1.2

Refrigerant piping insulation .......................................

9

6.2

Connecting the refrigerant piping ..............................................

10

6.2.1

To connect the refrigerant piping to the indoor unit .... 10

7 Electrical installation

10

7.1

Specifications of standard wiring components ..........................

10

7.2

To connect the electrical wiring to the indoor unit .....................

10

7.3

To connect optional accessories (wired user interface, central
user interface, wireless adapter, etc.) .......................................

11

8 Finishing the indoor unit installation

11

8.1

To finish the indoor unit installation ...........................................

11

8.2

To close the indoor unit .............................................................

11

8.2.1

To close the electrical wiring box and close the
terminal block.............................................................. 11

8.2.2

To re-install the front grille .......................................... 11

8.2.3

To re-install the front panel ......................................... 11

9 Commissioning

12

9.1

To perform a test run .................................................................

12

9.1.1

To perform a test run using the user interface ............ 12

10 Disposal

12

11 Technical data

12

11.1

Wiring diagram ..........................................................................

12

11.1.1

Unified wiring diagram legend..................................... 12

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied materials follow the instructions from Daikin and, in
addition,  comply  with  applicable  legislation  and  are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Unit installation (see 

"5 Unit installation"

 [

4

 4])

WARNING

CVXM-A  and  FVXM-A  Floor  Standing  range  is  allowed  to
be  combined  ONLY  with  systems  with  total  refrigerant
amount  <1.842  kg.  Therefore  in  case  of  combination  with
outdoor  units  3MXM40N8  or  3MXM52N8,  the  total  liquid
refrigerant piping length of the installation MUST be ≤30 m.

Summary of Contents for FVXM25A2V1B

Page 1: ...stallation manual Split system air conditioners English Installation manual Split system air conditioners CVXM20A2V1B CVXM20A3V1B FVXM25A2V1B FVXM35A2V1B FVXM50A2V1B FVXM25A3V1B FVXM35A3V1B FVXM50A3V1...

Page 2: ...iring diagram legend 12 1 About the documentation 1 1 About this document INFORMATION Make sure that the user has the printed documentation and ask him her to keep it for future reference Target audie...

Page 3: ...e in contact with sharp edges or piping particularly on the high pressure side Do NOT use taped wires stranded conductor wires extension cords or connections from a star system They can cause overheat...

Page 4: ...ed version of Android or iOS specified on app daikineurope com Internet line and communicating device such as modem router etc Wireless LAN access point Installed free Daikin Residential Controller ap...

Page 5: ...ck 1 Remove the front grille 2 Remove 1 lower screw 3 Lift the sensor securing plate 4 Move the metal plate cover down and then towards you to remove it c b c b a 1 2 3 a Screw b Sensor securing plate...

Page 6: ...n is finished attach the front panel and the front grille in their original position Wall mounted installation 82 166 0 6 mm 627 5 750 0 0 6 553 300 200 285 115 238 b b b b 75 0 6 75 45 65 65 45 d e 7...

Page 7: ...ng Half concealed installation A Front view B Side view C Top view a Extra filler board b Screw hole 6 c Hole d Left back piping hole location e Right back piping hole location f Right left piping hol...

Page 8: ...ame same of the other side d Slit portion for the bottom piping 1 Cut off the slit portion using nippers 2 Remove an burrs along the cut section using a half round needle file 5 3 4 To provide drainag...

Page 9: ...it 3MXM40N8 or 3MXM52N8 with the indoor units CVXM A and or FVXM A The total piping length MUST be 30 m Foreign materials inside pipes including oils for fabrication must be 30 mg 10 m Refrigerant pip...

Page 10: ...voltage category III WARNING If the supply cord is damaged it MUST be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard WARNING Do NOT connect th...

Page 11: ...h each turn a b c d e f a Interconnection cable b Gas pipe c Gas pipe insulation d Insulation tape e Liquid pipe f Liquid pipe insulation 2 Pass the pipes through the wall hole and seal the gaps with...

Page 12: ...and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery 11 Technical data A subset of the latest technical da...

Page 13: ...verload protector Q M Thermo switch Q R Residual current device R Resistor R T Thermistor RC Receiver S C Limit switch S L Float switch S NG Refrigerant leak detector S NPH Pressure sensor high S NPL...

Page 14: ......

Page 15: ......

Page 16: ...3P477070 2M 2021 09 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...