background image

3

English

Do not leave the remote controller wherever there is a 
risk of wetting.

If water gets into the remote controller there is a risk of 
electrical leakage and damage to electronic components.

Watch your steps at the time of air filter cleaning or 
inspection.

High-place work is required, to which utmost attention must 
be paid.
If the scaffold is unstable, you may fall or topple down, thus 
causing injury.

Do not remove the outdoor unit’s outlet side grille.

The grille protects against the unit’s high speed fan, which 
may cause injury.

To avoid injury, do not touch the air inlet or aluminum 
fins of the air conditioner.
Do not place objects that are susceptible to moisture 
directly beneath the indoor or outdoor units.

Under certain conditions, condensation on the unit or 
refrigerant piping, air filter dirt or drain blockage may cause 
dripping, resulting in fouling or failure of the object 
concerned.

Do not place heaters directly below the indoor unit, as 
resulting heat can cause deformation.
Do not place appliances that produce naked flames in 
places exposed to the airflow from the air conditioner 
as this may impair combustion of the burner.
Do not block air inlets nor outlets.

Impaired airflow may result in insufficient performance or 
trouble.

Do not use the air conditioner for purposes other than 
those for which it is intended.

Do not use the air conditioner for cooling precision 
instruments, food, plants, animals or works of art as this 
may adversely affect the performance, quality and/or 
longevity of the object concerned.

Do not install the air conditioner at any place where 
there is a danger of flammable gas leakage.

In the event of a gas leakage, build-up of gas near the air 
conditioner may result in a fire.

Carry out drain piping properly to ensure complete 
drainage.

If drain piping is not carried out properly, drain will not flow 
out. Then, dirt and debris may be accumulated in the drain 
piping and may cause water leakage. If it occurs, stop the 
air conditioner and call your local dealer for assistance.

• NOTE TO SERVICE PERSONNEL

WARNING

RISK OF ELECTRIC SHOCKS OR A FIRE

When checking the electric components (such 
as the inside of the control box, fan motor, drain 
pump, etc.), make sure to shut off all power 
supply for the air conditioner (including both 
indoor and outdoor units).

When cleaning the heat exchanger, make sure 
to remove the electronic components above (If 
they get cleaning agent, there is a risk that the 
components will burn out because of insulation 
degradation). 

CAUTION! DANGER OF ELECTRIC 

Shut off power supply before work.

Never open the control box lid for 10 minutes 
after shutting off the power supply because 
there is residual voltage.

After opening the control box lid, measure 
residual voltage between the points shown in 

Fig. 1

 on the printed circuit board by the tester 

without touching the live part and confirm that 
the residual voltage is DC50V or below.

After power failure, operation will restart 
automatically.

2. WHAT TO DO BEFORE 

OPERATION

This operation manual is for the following systems 
with standard control.
Before initiating operation, contact your local dealer 
for the operation that corresponds to your system.

Figure 1

1

Control box

2

Printed circuit board

3

Measuring points for residual voltage

A

Pair system or simultaneous operation system

B

Multi system

1

Unit with remote controller

2

Unit without remote controller (when used as simulta-
neous operation)

- +

0

A1P

X1M

C -

C +

X27A

C-

C+

1

2

3

A

1

2

OUTDOOR

INDOOR

4PEN465543-1.book  Page 3  Tuesday, March 14, 2017  3:08 PM

Summary of Contents for FUA71AVEB

Page 1: ...OPERATION MANUAL FUA71AVEB FUA100AVEB FUA125AVEB Split system air conditioners...

Page 2: ...se by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have b...

Page 3: ...tility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the air co...

Page 4: ...e In the event of a gas leakage build up of gas near the air conditioner may result in a fire Carry out drain piping properly to ensure complete drainage If drain piping is not carried out properly dr...

Page 5: ...roller 2 Unit without remote controller when used as simulta neous operation B OUTDOOR INDOOR 1 1 NOTE Contact your local dealer in case of changing the combination or setting of group control and two...

Page 6: ...e there are machines generating electromagnetic waves h Filled with acid and or alkaline steam or vapor Is a snow protection measure taken For details consult your local dealer about snow protection h...

Page 7: ...set The airflow direction becomes horizontal to prevent a draft of cool air to the inhabitants The remote controller displays the set airflow direction that is set DEFROST OPERATION Frost removal ope...

Page 8: ...ller to set the airflow direction For details refer to the operation manual attached to the remote controller The horizontal blades at the air outlet are closed while the indoor unit stops AIRFLOW DIR...

Page 9: ...outdoor unit is not in operation depends on the model 2 The setting before the power circuit breaker is cut off is stored The timer setting is cleared Fully use the function of airflow direction adju...

Page 10: ...50 hours equivalent to a half year a knob a Grille upper part projection b Filter c Projection d Air filter end a a 2 1 2 1 1 2 a b b b c d 3 Clean the filter Clean the contamination with a vacuum cle...

Page 11: ...ot wash the suction grille with warm water of 50 C or higher It may cause discoloration and deformation When drying the suction grille do not heat it with fire It may cause burning Do not use such as...

Page 12: ...cuit breaker during seasonal use of the HEATING OPERATION WHAT TO DO WHEN STOPPING THE AIR CONDITIONER FOR A LONG PERIOD Turn on FAN OPERATION for a half day on the fine day and dry the indoor unit Th...

Page 13: ...ndoor unit is in the FAN OPERATION COOLING OPERATION AUTOMATIC COOLING OPERATION Lower the set temperature HEATING OPERATION AUTOMATIC HEATING OPERATION Raise the set temperature The operation starts...

Page 14: ...while the horizontal blades close VI WHITE MIST COMES OUT OF THE AIR CONDITIONER When humidity is high during the COOLING OPERATION In oily or dusty places If the inside of an indoor unit is extremely...

Page 15: ...he power supply Check if the power circuit breaker is blown If the tab of power circuit breaker is in the OFF position turn the power on with the power circuit breaker switch If the tab of power circu...

Page 16: ...following malfunctions occurs take the measures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person WARNING When the air conditioner is malfun...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...4P465543 1 2017 01 Copyright 2017 Daikin...

Reviews: