background image

11

English

CLEANING BEFORE AND AFTER 
SEASONAL USE

WHAT TO DO WHEN START UP AFTER A 
LONG STOP

Confirm the following.

Check that the air inlet and outlet of indoor and 
outdoor unit are not blocked.
Remove any obstacle.
Obstacles decrease the fan speed, and cause 
performance decrease and breakage of the 
devices.

Clean the air filter.

After cleaning the air filter, make sure to attach it.
(Refer to "

MAINTENANCE (FOR SERVICE 

PERSONNEL)

" on page 8.)

For information on how to install, remove, or clean 
a optional sold air filter, refer to the user’s manual 
attached to the air filter.

Turn off the indication "

" or "Time to clean 

filter" displayed on the remote controller after 
turning on the power.

For details, refer to the operation manual attached 
to the remote controller.
The indication can be turned off whether in 
operation or at stop. 

Turn on the power circuit breaker at least 
6 hours before operation.

This is required in order to activate the air 
conditioner smoothly, and to protect the air 
conditioner.

The display on the remote controller will be shown 
when the power circuit breaker is turned on.

HEATING OPERATION within 6 hours after 
power is supplied to the air conditioner.

Some model series perform the following operation 
to protect the devices.
If the HEATING OPERATION is performed within 
6 hours after power is supplied to the air conditioner, 
the indoor fan stops for about 10 minutes during the 
outdoor unit operation to protect the devices.
The above operation is performed not only for 
installation, but every time the power circuit breaker 
is turned off/on.
For comfortable use, do not turn off the power circuit 
breaker during seasonal use of the HEATING 
OPERATION.

WHAT TO DO WHEN STOPPING THE AIR 
CONDITIONER FOR A LONG PERIOD

Turn on FAN OPERATION for a half day on the 
fine day and dry the indoor unit.

This can prevent the causes of mould.

Turn off the power circuit breaker.

During the power circuit breaker is turned on, 
some watts of electricity is being used even if the 
air conditioner is not operating.
Turn off the power circuit breaker for saving 
energy.

The display on the remote controller will vanish 
when the power circuit breaker is turned off. 

Clean the air filter.

Be sure to replace the air filter to its original place 
after cleaning.
(Refer to "

MAINTENANCE (FOR SERVICE 

PERSONNEL)

" on page 8.)

For information on how to install, remove, or clean 
an optional sold air filter, refer to the user’s 
manual attached to the air filter.

NOTE 

The inside of the air conditioner may become 
contaminated after several seasons of use, 
potentially causing performance degradation and 
water leakage.
Ask your local dealer for details on cleaning the 
inside of the indoor unit. This operation requires a 
qualified service person.

9. NOT MALFUNCTION OF THE AIR 

CONDITIONER

The following symptoms do not indicate air 
conditioner malfunction

HEATING OPERATION within 6 hours after the 
power is supplied to the air conditioner.
Some model series perform the following 
operation to protect the devices.
If the HEATING OPERATION is performed within 
6 hours after the power is supplied to the air 
conditioner, the indoor fan stops for about 
10 minutes during the outdoor unit operation to 
protect the devices.
The above operation is performed not only for 
installation, but every time the power circuit 
breaker is turned off/on.
For comfortable use, do not turn off the power 
circuit breaker during seasonal use of the 
HEATING OPERATION.

4PEN465543-1.book  Page 11  Tuesday, March 14, 2017  3:08 PM

Summary of Contents for FUA100AVEB

Page 1: ...OPERATION MANUAL FUA71AVEB FUA100AVEB FUA125AVEB Split system air conditioners...

Page 2: ...se by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have b...

Page 3: ...tility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the air co...

Page 4: ...e In the event of a gas leakage build up of gas near the air conditioner may result in a fire Carry out drain piping properly to ensure complete drainage If drain piping is not carried out properly dr...

Page 5: ...roller 2 Unit without remote controller when used as simulta neous operation B OUTDOOR INDOOR 1 1 NOTE Contact your local dealer in case of changing the combination or setting of group control and two...

Page 6: ...e there are machines generating electromagnetic waves h Filled with acid and or alkaline steam or vapor Is a snow protection measure taken For details consult your local dealer about snow protection h...

Page 7: ...set The airflow direction becomes horizontal to prevent a draft of cool air to the inhabitants The remote controller displays the set airflow direction that is set DEFROST OPERATION Frost removal ope...

Page 8: ...ller to set the airflow direction For details refer to the operation manual attached to the remote controller The horizontal blades at the air outlet are closed while the indoor unit stops AIRFLOW DIR...

Page 9: ...outdoor unit is not in operation depends on the model 2 The setting before the power circuit breaker is cut off is stored The timer setting is cleared Fully use the function of airflow direction adju...

Page 10: ...50 hours equivalent to a half year a knob a Grille upper part projection b Filter c Projection d Air filter end a a 2 1 2 1 1 2 a b b b c d 3 Clean the filter Clean the contamination with a vacuum cle...

Page 11: ...ot wash the suction grille with warm water of 50 C or higher It may cause discoloration and deformation When drying the suction grille do not heat it with fire It may cause burning Do not use such as...

Page 12: ...cuit breaker during seasonal use of the HEATING OPERATION WHAT TO DO WHEN STOPPING THE AIR CONDITIONER FOR A LONG PERIOD Turn on FAN OPERATION for a half day on the fine day and dry the indoor unit Th...

Page 13: ...ndoor unit is in the FAN OPERATION COOLING OPERATION AUTOMATIC COOLING OPERATION Lower the set temperature HEATING OPERATION AUTOMATIC HEATING OPERATION Raise the set temperature The operation starts...

Page 14: ...while the horizontal blades close VI WHITE MIST COMES OUT OF THE AIR CONDITIONER When humidity is high during the COOLING OPERATION In oily or dusty places If the inside of an indoor unit is extremely...

Page 15: ...he power supply Check if the power circuit breaker is blown If the tab of power circuit breaker is in the OFF position turn the power on with the power circuit breaker switch If the tab of power circu...

Page 16: ...following malfunctions occurs take the measures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person WARNING When the air conditioner is malfun...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...4P465543 1 2017 01 Copyright 2017 Daikin...