background image

7

English

CHARACTERISTICS OF THE PROGRAM 
DRY OPERATION

This operation lowers the humidity without 
lowering the indoor temperature. The indoor 
temperature when the operation button is pressed 
will be the set temperature. At this time, the fan 
speed and temperature are set automatically, so 
the remote controller does not display the fan 
speed and set temperature.
To efficiently lower the indoor temperature and 
humidity, first use the COOLING OPERATION to 
lower the indoor temperature, and then use the 
PROGRAM DRY OPERATION. When the indoor 
temperature is lowered, airflow from the indoor 
unit may stop.

When operating continuously at downward airflow 
direction, air blows in the automatic set direction 
for a period of time to prevent condensation on 
the horizontal blades. (The remote controller 
displays the airflow direction that is set.)

If the PROGRAM DRY OPERATION is used 
when the indoor temperature is low, frost forms 
the heat exchanger of the indoor unit. In this case, 
the air conditioner automatically switches to the 
DEFROST OPERATION for a while.
The low fan speed or a gentle wind is used to 
prevent the discharge of melt water.

SOUND PRESSURE LEVEL

Sound pressure level is less than 70 dB(A).

AIRFLOW DIRECTION ADJUST

Airflow direction adjust can be individually set for 
each air outlet. (only BRC1E53)

Check the air outlet identification mark (refer to 
page 4), and use the remote controller to set the 
airflow direction. (For details, refer to the 
operation manual attached to the remote 
controller.)

The horizontal blades at the air outlet are closed 
while the indoor unit stops.

AIRFLOW DIRECTION ADJUST

Press the AIRFLOW DIRECTION ADJUST/
SETTING button to adjust the airflow direction.

Up and down adjustment

The AIRFLOW DIRECTION 
display swings as shown left and 
the airflow direction continuously 
varies. (Automatic swing setting)

1

swing

Press AIRFLOW DIRECTION 
ADJUST/SETTING button to 
select the air direction of your 
choice.

The AIRFLOW DIRECTION 
display stops swinging and the 
airflow direction is fixed (Fixed 
airflow direction setting).

MOVEMENT OF THE HORIZONTAL BLADE

For the following conditions, micro computer 
controls the airflow direction so it may be different 
from the display. 

NOTE

When group control is performed on the 
simultaneous operation system (twin and triple), 
airflow direction cannot be individually set on the 
slave units.

Operation 
mode

COOLING

AUTOMATIC 
COOLING

PROGRAM DRY

HEATING

AUTOMATIC 
HEATING

Up and down 
direction

Air blows in the 
automatic set direction 
for a period of time to 
prevent condensation 
on the horizontal 
blades.

When operating 
continuously at 
downward airflow 
direction

The airflow direction 
becomes horizontal so 
that it does not blow 
directly toward your 
body.

When room 
temperature is 
higher than the set 
temperature

When the HEATING 
OPERATION starts 
or during the 
DEFROST 
OPERATION (if frost 
forms on the outdoor 
unit)

1

Indoor unit (Slave)

2

Indoor unit (Master)

3

Outdoor unit

4

Remote controller

5

Twin

6

Triple

5

1

1

2

3

3

4

6

4PEN465543-1.book  Page 7  Tuesday, March 14, 2017  3:08 PM

Summary of Contents for FUA100AVEB

Page 1: ...OPERATION MANUAL FUA71AVEB FUA100AVEB FUA125AVEB Split system air conditioners...

Page 2: ...se by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have b...

Page 3: ...tility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the air co...

Page 4: ...e In the event of a gas leakage build up of gas near the air conditioner may result in a fire Carry out drain piping properly to ensure complete drainage If drain piping is not carried out properly dr...

Page 5: ...roller 2 Unit without remote controller when used as simulta neous operation B OUTDOOR INDOOR 1 1 NOTE Contact your local dealer in case of changing the combination or setting of group control and two...

Page 6: ...e there are machines generating electromagnetic waves h Filled with acid and or alkaline steam or vapor Is a snow protection measure taken For details consult your local dealer about snow protection h...

Page 7: ...set The airflow direction becomes horizontal to prevent a draft of cool air to the inhabitants The remote controller displays the set airflow direction that is set DEFROST OPERATION Frost removal ope...

Page 8: ...ller to set the airflow direction For details refer to the operation manual attached to the remote controller The horizontal blades at the air outlet are closed while the indoor unit stops AIRFLOW DIR...

Page 9: ...outdoor unit is not in operation depends on the model 2 The setting before the power circuit breaker is cut off is stored The timer setting is cleared Fully use the function of airflow direction adju...

Page 10: ...50 hours equivalent to a half year a knob a Grille upper part projection b Filter c Projection d Air filter end a a 2 1 2 1 1 2 a b b b c d 3 Clean the filter Clean the contamination with a vacuum cle...

Page 11: ...ot wash the suction grille with warm water of 50 C or higher It may cause discoloration and deformation When drying the suction grille do not heat it with fire It may cause burning Do not use such as...

Page 12: ...cuit breaker during seasonal use of the HEATING OPERATION WHAT TO DO WHEN STOPPING THE AIR CONDITIONER FOR A LONG PERIOD Turn on FAN OPERATION for a half day on the fine day and dry the indoor unit Th...

Page 13: ...ndoor unit is in the FAN OPERATION COOLING OPERATION AUTOMATIC COOLING OPERATION Lower the set temperature HEATING OPERATION AUTOMATIC HEATING OPERATION Raise the set temperature The operation starts...

Page 14: ...while the horizontal blades close VI WHITE MIST COMES OUT OF THE AIR CONDITIONER When humidity is high during the COOLING OPERATION In oily or dusty places If the inside of an indoor unit is extremely...

Page 15: ...he power supply Check if the power circuit breaker is blown If the tab of power circuit breaker is in the OFF position turn the power on with the power circuit breaker switch If the tab of power circu...

Page 16: ...following malfunctions occurs take the measures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person WARNING When the air conditioner is malfun...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...4P465543 1 2017 01 Copyright 2017 Daikin...