4 About the unit

Installation manual

4

FTXTA30B2V1B(W)(B)

Daikin room air conditioner

3P482320-12U – 2021.03

d

Titanium apatite deodorising filter and silver particle filter
(Ag-ion filter)

e

Indoor unit fixing screw (M4×12L). Refer to 

"8.3 To fix the

unit on the mounting plate"

 [

4

 9].

f

Dry battery AAA.LR03 (alkaline) for user interface

g

User interface holder

h

User interface

i

Mounting plate

j

Screw cover

k

Spare SSID sticker with release paper (attached to the
unit)

Spare SSID sticker. 

Do NOT throw away the spare sticker. Keep

it  in  a  safe  place  in  case  it  is  needed  in  future  (e.g.  in  case  the
front grille was replaced attach it to the new front grille).

4

About the unit

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

4.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Operation mode

Operation range

Cooling

(a)(b)

▪ Outdoor temperature: –10~46°C DB

▪ Indoor temperature: 18~32°C DB

▪ Indoor humidity: ≤80%

Heating

(a)

▪ Outdoor temperature: –25~24°C DB

▪ Indoor temperature: 10~30°C DB

Drying

(a)

▪ Outdoor temperature: –10~46°C DB

▪ Indoor temperature: 18~32°C DB

▪ Indoor humidity: ≤80%

(a)

A safety device might stop the operation of the system if the unit
runs outside its operation range.

(b)

Condensation and water dripping might occur if the unit runs
outside its operation range.

4.2

About the wireless LAN

For detailed specifications, installation instructions, setting methods,
FAQ, declaration of conformity and the latest version of this manual,
visit 

app.daikineurope.com

.

INFORMATION

▪ Daikin  Industries  Czech  Republic  s.r.o.  declares  that

the  radio  equipment  type  inside  of  this  unit  is  in
compliance with Directive 2014/53/EU.

▪ This  unit  is  considered  as  combined  equipment

according to the definition of Directive 2014/53/EU.

4.2.1

Precautions when using the wireless LAN

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

4.2.2

Basic parameters

Parameter

Value

Frequency range

2400 MHz~2483.5 MHz

Radio protocol

IEEE 802.11b/g/n

Radio frequency channel

1~11

Output power

0 dBm~18 dBm

Effective radiated power

17 dBm (11b) / 13 dBm (11g) /
12 dBm (11n)

Power supply

DC 3.3 V / 500 mA

5

Unit installation

INFORMATION

If  you  are  not  sure  how  to  open  or  close  parts  of  the  unit
(front panel, electrical wiring box, front grille…) refer to the
installer reference guide of the unit for opening and closing
procedures.

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

5.1

Preparing the installation site

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

5.1.1

Installation site requirements of the
indoor unit

INFORMATION

The sound pressure level is less than 70 dBA.

Air flow.

 Make sure nothing blocks the air flow.

Drainage.

  Make  sure  condensation  water  can  be  evacuated

properly.

Wall insulation

. When conditions in the wall exceed 30°C and a

relative  humidity  of  80%,  or  when  fresh  air  is  inducted  into  the
wall,  then  additional  insulation  is  required  (minimum  10  mm
thickness, polyethylene foam).

Wall  strength. 

Check  whether  the  wall  or  the  floor  is  strong

enough to support the weight of the unit. If there is a risk, reinforce
the wall or the floor before installing the unit.

Spacing. 

Install the unit at least 1.8 m from the floor and keep the

following  requirements  in  mind  for  distances  from  the  walls  and
the ceiling:

Summary of Contents for FTXTA30B2V1BB

Page 1: ...Installation manual Daikin room air conditioner English Installation manual Daikin room air conditioner FTXTA30B2V1BW FTXTA30B2V1BB ...

Page 2: ...cal data 10 12 1 Wiring diagram 10 12 1 1 Unified wiring diagram legend 10 1 About the documentation 1 1 About this document INFORMATION Make sure that the user has the printed documentation and ask him her to keep it for future reference Target audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for...

Page 3: ... site and all electrical construction MUST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down Establish proper earthing Do NOT earth the unit to a utility pipe surge absorber or telephone earth Incomplete earthing may cause electrical shock Install the required fuses or circuit breakers Secure the electrical wiring with cabl...

Page 4: ...edical equipment E g persons using cardiac pacemakers or defibrillators This product may cause electromagnetic interference Auto control equipment E g automatic doors or fire alarm equipment This product may cause faulty behaviour of the equipment Microwave oven It may affect wireless LAN communications 4 2 2 Basic parameters Parameter Value Frequency range 2400 MHz 2483 5 MHz Radio protocol IEEE ...

Page 5: ... a a a a h 610 605 555 k j i a Recommended mounting plate fixing spots g Value for tape measure b Pocket for the pipe port cover h Position for tape measure at symbol c Use tape measure as shown i Drain hose d Tabs for placing a spirit level j Liquid pipe e Unit center k Gas pipe f Hole for embedded piping Ø65 mm 5 2 2 To drill a wall hole CAUTION For walls containing a metal frame or a metal boar...

Page 6: ...eft side left back or left bottom INFORMATION The factory default is right side piping For left side piping remove the piping from the right side and install it on the left side 1 Remove the insulation fixing screw on the right side and remove the drain hose 2 Remove the drain plug on the left side and attach it to the right side NOTICE Do NOT apply lubricating oil refrigerant oil to the drain plu...

Page 7: ... the refrigerant piping DANGER RISK OF BURNING SCALDING 6 2 1 To connect the refrigerant piping to the indoor unit WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable Pipe length Keep refrigerant piping as short as possible 1 Connect refrigerant piping to the unit using flare connections 2 Insulate the refrigerant piping interconnection cable and drain hose on th...

Page 8: ...make contact with electrical parts can cause malfunctions smoke or fire a b c a Terminal block b Electrical component block c Cable clamp 5 Strip the wire ends approximately 15 mm 6 Match wire colours with terminal numbers on the indoor unit terminal blocks and firmly screw the wires to the corresponding terminals 7 Connect the earth wire to the corresponding terminal 8 Firmly fix the wires with t...

Page 9: ...tom edge of the indoor unit with both hands until it is firmly caught by the mounting plate hooks 4 Secure the indoor unit to the mounting plate using 2 indoor unit fixing screws M4 12L accessory 9 Configuration 9 1 To set a different address In case 2 indoor units are installed in 1 room different addresses for 2 user interfaces can be set 1 Remove the cover and the batteries from the user interf...

Page 10: ...nts or squeezed pipes on the inside of the indoor and outdoor units There are NO refrigerant leaks The correct pipe size is installed and the pipes are properly insulated The stop valves gas and liquid on the outdoor unit are fully open 10 2 To perform a test run Prerequisite Power supply MUST be in the specified range Prerequisite Test run may be performed in cooling or heating mode Prerequisite ...

Page 11: ...K M Magnetic relay L Live L Coil L R Reactor M Stepper motor M C Compressor motor M F Fan motor M P Drain pump motor M S Swing motor MR MRCW MRM MRN Magnetic relay N Neutral n N Number of passes through ferrite core PAM Pulse amplitude modulation PCB Printed circuit board Symbol Meaning PM Power module PS Switching power supply PTC PTC thermistor Q Insulated gate bipolar transistor IGBT Q C Circui...

Page 12: ...3P482320 12U 2021 03 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...

Reviews: