5 Energy saving and optimum operation

Operation manual

7

FTXP50~71M2V1B
Daikin room air conditioner
3P511999-4E – 2018.09

5

Energy saving and optimum
operation

INFORMATION

▪ Even if the unit is turned OFF, it consumes electricity.

▪ When the power turns back on after a power break, the

previously selected mode will be resumed.

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

WARNING

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays. Doing so may result in
a fire.

Observe  the  following  precautions  to  ensure  the  system  operates
properly.

▪ Prevent  direct  sunlight  from  entering  a  room  during  cooling

operation by using curtains or blinds.

▪ Ventilate  often.  Extended  use  requires  special  attention  to

ventilation.

▪ Keep doors and windows closed. If the doors and windows remain

open,  air  will  flow  out  of  your  room  causing  a  decrease  in  the
cooling or heating effect.

▪ Be  careful  NOT  to  cool  or  heat  too  much.  To  save  energy,  keep

the temperature setting at a moderate level.

▪ NEVER place objects near the air inlet or the air outlet of the unit.

Doing  so  may  cause  a  reduced  heating/cooling  effect  or  stop
operation.

▪ Turn the breaker off when the unit is NOT used for longer periods

of time. If the breaker is on, the unit consumes electricity. Before
restarting the unit, turn the breaker on 6 hours before operation to
ensure smooth running.

▪ Condensation  may  form  if  the  humidity  is  above  80%  or  if  the

drain outlet gets blocked.

▪ Adjust  the  room  temperature  properly  for  a  comfortable

environment.  Avoid  excessive  heating  or  cooling.  Notice  that  it
may  take  some  time  for  the  room  temperature  to  reach  the  set
temperature. Consider using the timer setting options.

▪ Adjust the air flow direction to avoid cool air from gathering on the

floor  or  warm  air  against  the  ceiling.  (Up  during  cooling  or  dry
operation to the ceiling and down during heating operation.)

▪ Avoid direct air flow to room inhabitants.

▪ Operate  the  system  within  the  recommended  temperature  range

(26~28°C for cooling and 20~24°C for heating) to save energy.

6

Maintenance and service

6.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

In  Europe,  the 

greenhouse  gas  emissions

  of  the  total

refrigerant charge in the system (expressed as tonnes CO

2

equivalent) is used to determine the maintenance intervals.
Follow the applicable legislation.

Formula  to  calculate  the  greenhouse  gas  emissions:

GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000

Please contact your installer for more information.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

NOTICE

Maintenance  MUST  be  done  by  an  authorized  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  off.  Otherwise,  an
electric shock and injury may result.

Summary of Contents for FTXP50M2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXP50M2V1B FTXP60M2V1B FTXP71M2V1B...

Page 2: ...About the documentation 1 1 About this document Thank you for purchasing this product Please Keep the documentation for future reference Target audience End users INFORMATION This appliance is intende...

Page 3: ...n the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your installer Curtains Make sure that the s...

Page 4: ...to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT control th...

Page 5: ...l blades and louvers vertical blades will begin to swing 2 To use fixed position press and when the flaps and louvers reach the desired position Result and disappear from the LCD The flaps and the lou...

Page 6: ...Use this feature if the unit is operating and you want to stop operation after a certain time 1 Press Result is displayed on the LCD and the timer lamp lights up 2 Press again if you want to change t...

Page 7: ...ke some time for the room temperature to reach the set temperature Consider using the timer setting options Adjust the air flow direction to avoid cool air from gathering on the floor or warm air agai...

Page 8: ...g brush Possible consequence The surface finishing peels off DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the breaker off or pull out the supply cord Otherwise an el...

Page 9: ...into account before a long idle period 1 Set the mode to fan only by pressing button to dry the inside of the unit 2 After operation stops turn the breaker off 3 Clean the air filters and replace them...

Page 10: ...mpossible to fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date possibly listed...

Page 11: ......

Page 12: ...3P511999 4E 2018 09 Copyright 2018 Daikin...

Reviews: