background image

Table of Contents

Operation manual

2

FTXP50~71M2V1B

Daikin room air conditioner

3P511999-4E – 2018.09

Table of Contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 About the system

2

2.1

Indoor unit .................................................................................

2

2.1.1

Indoor unit display.......................................................

3

2.2

About the user interface ............................................................

3

2.2.1

Components: User interface .......................................

3

3 Before operation

3

3.1

To insert the batteries................................................................

3

3.2

To fix the user interface to the wall............................................

3

3.3

To turn on the power supply......................................................

4

4 Operation

4

4.1

Operation range ........................................................................

4

4.2

Operation mode and temperature setpoint................................

4

4.2.1

To start/stop operation and to set the temperature.....

4

4.3

Airflow rate ................................................................................

4

4.3.1

To adjust the airflow rate.............................................

4

4.4

Airflow direction .........................................................................

5

4.4.1

To adjust vertical airflow direction...............................

5

4.4.2

To adjust horizontal airflow direction...........................

5

4.4.3

To use 3-D airflow direction ........................................

5

4.5

Comfort airflow operation ..........................................................

5

4.5.1

To start/stop Comfort airflow operation.......................

5

4.6

Powerful operation ....................................................................

5

4.6.1

To start/stop Powerful operation .................................

5

4.7

Econo operation ........................................................................

6

4.7.1

To start/stop Econo operation.....................................

6

4.8

OFF/ON timer operation ............................................................

6

4.8.1

To start/stop OFF timer operation...............................

6

4.8.2

To start/stop ON timer operation.................................

6

4.8.3

To combine OFF timer and ON timer..........................

6

5 Energy saving and optimum operation

7

6 Maintenance and service

7

6.1

Overview: Maintenance and service .........................................

7

6.2

To clean the indoor unit and user interface ...............................

8

6.3

To clean the front panel.............................................................

8

6.4

About the air filters ....................................................................

8

6.5

To open the front panel .............................................................

8

6.6

To clean the air filters ................................................................

8

6.7

To clean the titanium apatite deodorizing filter and the silver
particle filter (Ag-ion filter) .........................................................

9

6.8

To replace the titanium apatite deodorizing filter and the silver
particle filter (Ag-ion filter) .........................................................

9

6.9

To close the front panel.............................................................

9

6.10

To take following items into account before a long idle period..

9

7 Troubleshooting

9

8 Disposal

10

1

About the documentation

1.1

About this document

Thank you for purchasing this product. Please:

▪ Keep the documentation for future reference.

Target audience

End users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety  instructions  that  you  must  read  before  operating  your

system

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

2

About the system

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

2.1

Indoor unit

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.

INFORMATION

The sound pressure level is less than 70 dBA.

WARNING

▪ Do not modify, disassemble, remove, reinstall or repair

the unit yourself as incorrect dismantling or installation
may  cause  an  electric  shock  or  fire.  Contact  your
dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  mildly  flammable,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

Summary of Contents for FTXP50M2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXP50M2V1B FTXP60M2V1B FTXP71M2V1B...

Page 2: ...About the documentation 1 1 About this document Thank you for purchasing this product Please Keep the documentation for future reference Target audience End users INFORMATION This appliance is intende...

Page 3: ...n the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your installer Curtains Make sure that the s...

Page 4: ...to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT control th...

Page 5: ...l blades and louvers vertical blades will begin to swing 2 To use fixed position press and when the flaps and louvers reach the desired position Result and disappear from the LCD The flaps and the lou...

Page 6: ...Use this feature if the unit is operating and you want to stop operation after a certain time 1 Press Result is displayed on the LCD and the timer lamp lights up 2 Press again if you want to change t...

Page 7: ...ke some time for the room temperature to reach the set temperature Consider using the timer setting options Adjust the air flow direction to avoid cool air from gathering on the floor or warm air agai...

Page 8: ...g brush Possible consequence The surface finishing peels off DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the breaker off or pull out the supply cord Otherwise an el...

Page 9: ...into account before a long idle period 1 Set the mode to fan only by pressing button to dry the inside of the unit 2 After operation stops turn the breaker off 3 Clean the air filters and replace them...

Page 10: ...mpossible to fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date possibly listed...

Page 11: ......

Page 12: ...3P511999 4E 2018 09 Copyright 2018 Daikin...

Reviews: