6
|
Installation
Installer reference guide
24
FTXP50~7 FTXF20~7 ATXF50~71A2V1B
Daikin room air conditioner
4P513661-8H – 2019.12
6.2.2 To re-install the front panel
1
Attach the front panel. Align the shafts with the slots and push them all the
way in.
2
Close the front panel slowly; press at both sides and at the centre.
6.2.3 To remove the front grille
CAUTION
Wear adequate personal protective equipment (protective gloves, safety glasses,…)
when installing, maintaining or servicing the system.
1
Remove the front panel to remove the air filter.
2
Remove 2 screws (class 20~35) or 3 screws (class 50~71) from the front grille.
3
Push down the 3 upper hooks marked with a symbol with 3 circles.
a
b
a
a
Upper hook
b
Symbol with 3 circles
4
We recommend opening the flap before removing the front grille.
5
Place both hands under the centre of the front grille, push it up and then
toward you.
1
2
6.2.4 To re-install the front grille
1
Install the front grille and firmly engage the 3 upper hooks.
2
Install 2 screws (class 20~35) or 3 screws (class 50~71) back on the front grille.
3
Install the air filter and then mount the front panel.
6.2.5 To remove the electrical wiring box cover
1
Remove the front grille.
2
Remove 1 screw from the electrical wiring box.
3
Open the electrical wiring box cover by pulling the protruding part on the top
of the cover.
4
Unhook the tab on the bottom and remove the electrical wiring box cover.