background image

Table of contents

Installation manual

5

(A)(F)TXP20~3 FTXF20~3 FTXF20~25B5V1B
Daikin room air conditioner
3P519299-1H – 2019.09

Table of contents

1 About the documentation

5

1.1

About this document..................................................................

5

2 About the box

5

2.1

Indoor unit .................................................................................

5

2.1.1

To remove the accessories from the indoor unit.........

5

3 About the unit

5

3.1

System layout ............................................................................

5

3.2

Operation range ........................................................................

5

4 Preparation

6

4.1

Preparing the installation site ....................................................

6

4.1.1

Installation site requirements of the indoor unit ..........

6

4.2

Preparing refrigerant piping .......................................................

6

4.2.1

Refrigerant piping requirements..................................

6

4.2.2

Refrigerant piping insulation .......................................

6

5 Installation

6

5.1

Opening the units ......................................................................

6

5.1.1

To open the indoor unit ...............................................

6

5.2

Installing the indoor unit ............................................................

7

5.2.1

To install the mounting plate .......................................

7

5.2.2

To drill a wall hole .......................................................

8

5.2.3

To remove the pipe port cover ....................................

8

5.2.4

To provide drainage ....................................................

8

5.3

Connecting the refrigerant piping ..............................................

8

5.3.1

Guidelines when connecting the refrigerant piping .....

8

5.3.2

To connect the refrigerant piping to the indoor unit ....

9

5.4

Connecting the electrical wiring.................................................

9

5.4.1

To connect the electrical wiring on the indoor unit......

9

5.5

Finishing the indoor unit installation ..........................................

10

5.5.1

To insulate the drain piping, refrigerant piping and
interconnection cable .................................................. 10

5.5.2

To pass the pipes through the wall hole ..................... 10

5.5.3

To fix the unit on the mounting plate........................... 10

6 Configuration

10

6.1

To set a different address..........................................................

10

7 Commissioning

11

7.1

Checklist before commissioning ................................................

11

7.2

To perform a test run .................................................................

11

7.2.1

To perform a test run in winter season ....................... 12

8 Disposal

12

9 Technical data

13

9.1

Wiring diagram ..........................................................................

13

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

About the box

2.1

Indoor unit

INFORMATION

The  following  figures  are  just  examples  and  may  NOT
completely match your system layout.

2.1.1

To remove the accessories from the
indoor unit

3

About the unit

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

3.1

System layout

3.2

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Operation mode

Operation range

Cooling

(a)(b)

▪ Outdoor temperature: –10~46°C

▪ Indoor temperature: 18~32°C

▪ Indoor humidity: ≤80%

Heating

(a)

▪ Outdoor temperature: –15~24°C

▪ Indoor temperature: 10~30°C

Drying

(a)

▪ Outdoor temperature: –10~46°C

▪ Indoor temperature: 18~32°C

▪ Indoor humidity: ≤80%

If operated outside the operation range:

Summary of Contents for FTXP35L5V1B

Page 1: ...l Daikin room air conditioner English Installation manual Daikin room air conditioner FTXP20L5V1B FTXP25L5V1B FTXP35L5V1B ATXP20L5V1B ATXP25L5V1B ATXP35L5V1B FTXF20A5V1B FTXF25A5V1B FTXF35A5V1B FTXF20...

Page 2: ...atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lietoti atbilsto i ra ot ja nor d jumiem atbilst sekojo iem standartiem un...

Page 3: ...odytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lietoti atbilsto i ra ot ja nor d jumiem atbilst sekojo iem standartiem un citiem normat vie...

Page 4: ...na imi navodili on vastavuses j rgmis t e standardi te ga v i teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus normi...

Page 5: ...ep it for future reference Target audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial...

Page 6: ...horic acid deoxidised seamless copper for refrigerant Foreign materials inside pipes including oils for fabrication must be 30 mg 10 m Refrigerant piping diameter Use the same diameters as the connect...

Page 7: ...s 20 35 back on the front grille 3 Install the air filter and then mount the front panel To remove the electrical wiring box cover 1 Remove the front grille 2 Remove 1 screw from the electrical wiring...

Page 8: ...Bore a 65 mm large feed through hole in the wall with a downward slope towards the outside 2 Insert a wall embedded pipe into the hole 3 Insert a wall cover into the wall pipe 65 a b c a Wall embedde...

Page 9: ...arly qualified persons in order to avoid a hazard WARNING Do NOT connect the power supply to the indoor unit This could result in electrical shock or fire WARNING Do NOT use locally purchased electric...

Page 10: ...ory f Bottom frame 5 5 2 To pass the pipes through the wall hole 1 Shape the refrigerant pipes along the pipe path marking on the mounting plate a b c c d e a Drain hose b Caulk this hole with putty o...

Page 11: ...tallation of the unit first check the items listed below Once all checks are fulfilled the unit must be closed Power up the unit after it is closed You read the complete installation instructions as d...

Page 12: ...ng the air conditioner in Cooling mode in winter set it to test run operation using the following method For FTXP and ATXP units 1 Press and simultaneously 2 Press 3 Select 4 Press 5 Press to switch t...

Page 13: ...DS DIP SWITCH E H HEATER F U FU FOR CHARACTERISTICS FUSE REFER TO PCB INSIDE YOUR UNIT FG CONNECTOR FRAME GROUND H HARNESS H P LED V L PILOT LAMP LIGHT EMITTING DIODE HAP LIGHT EMITTING DIODE SERVICE...

Page 14: ......

Page 15: ......

Page 16: ...TEMLER SAN T C A STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P519299 1H 2...

Reviews: