Safety Precautions

Accessories

 

 – 

,  

Choosing an Installation Site

• Before choosing the installation site, obtain user approval.

1.

Indoor unit

• The indoor unit should be sited in a place where: 

1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air inlet and air outlet have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the 

remote controller range,

8) the unit is at least 3.5 feet (1m) away from any television or radio set (unit may cause interference with the picture or sound),
9) no laundry equipment is located.

WARNING

• During pump-down, stop the compressor before removing the refrigerant piping.

If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, 
causing abnormally high pressure which could lead to equipment damage or and personal injury.

• During installation, attach the refrigerant piping securely before running the compressor.

If the refrigerant pipes are not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, 
causing abnormally high pressure which could lead to equipment damage and personal injury.

• Be sure to install a ground fault circuit interrupter breaker.

Failure to install a ground fault circuit interrupter breaker may result in electrically shocks, or fire personal injury.

CAUTION

• Do not install the air conditioner where gas leakage would be exposed to open flames.

If the gas leaks and builds up around the unit, it may catch fire.

• Establish drain piping according to the instructions of this manual. 

Inadequate piping may cause water damage.

• Tighten the flare nut according to the specified torque. A torque wrench should be used.

If the flare nut is tightened too much, the flare nut may crack over time and cause refrigerant leakage.

• Do not touch the heat exchanger fins.

Improper handling may result in injury.

• Be very careful about product transportation.

Some products use PP bands for packaging. Do not use any PP bands for a means of transportation. It is dangerous.

• Electrical work must be performed in accordance with the NEC/CEC by authorized personnel only.

 

Mounting plate

1

 Remote controller holder

1

 Operation manual

1

 Mounting plate fixing screw 

3/16” × 1” (M4 × 25mm)

9

 Fixing screw for remote controller 

holder 1/8” × 13/16” (M3 × 20mm)

2

 

Installation manual

1

 Titanium apatite photocatalytic 

air-purifying filter

2

 Dry battery AAA. LR03 

(alkaline)

2

 Wireless remote controller

1

 Indoor unit fixing screw 

3/16” × 1/2” (M4 × 12mm)

2

Indoor unit

A

K

A

E

J

B

F

K

C

G

D

H

01_EN_3P276866-2D.fm  Page 2  Friday, February 18, 2011  4:07 PM

Summary of Contents for FTXN15KVJU

Page 1: ...TION MANUAL DAIKIN ROOM AIR CONDITIONER English Français Español Installation manual Manuel d installation Manual de instalación MODELS FTXN15KVJU FTXN18KVJU FTXN24KVJU 00_CV_3P276866 2D fm Page 1 Friday February 18 2011 4 21 PM ...

Page 2: ...tning rods because lightning strikes could cause a severe shock hazard resulting in severe injury or death and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death WARNING Installation should be left to the authorized dealer or another trained professional Improper installation may cause water leakage electrical shock fire or equipment damage Inst...

Page 3: ...mp down air will be sucked in when the compressor is run causing abnormally high pressure which could lead to equipment damage and personal injury Be sure to install a ground fault circuit interrupter breaker Failure to install a ground fault circuit interrupter breaker may result in electrically shocks or fire personal injury CAUTION Do not install the air conditioner where gas leakage would be e...

Page 4: ...e type of unit purchased by the customer The default settings are on the heat pump side For cooling only Outdoor unit model RKN Set the DIP switch on the cooling only side For heat pump Outdoor unit model RXN Check that the DIP switch are on the heat pump side If they are set on the cooling only side move them to the heat pump side DIP switch Heat pump Cooling only DIP switch Heat pump Cooling onl...

Page 5: ... insulation pipe to an appropriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line Caulk pipe hole gap with putty The mounting plate should be installed on a wall which can support the weight of the indoor unit How to attach the indoor unit Hook the claws of the bottom frame to the mounting plate If the claws are difficult to hook remove the front gri...

Page 6: ...ront grille there are 3 upper hooks Lightly pull the front grille toward you with one hand and push down on the hooks with the fingers of your other hand When there is no work space because the unit is close to ceiling CAUTION Be sure to wear protection gloves Place both hands under the center of the front grille and while pushing up pull it toward you Installation method 1 Install the front grill...

Page 7: ...NING Do not use mineral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for previous installations Only use parts which are delivered with the unit Never install a drier to this R410A unit in order to guarantee its lifetime The drying material may dissolve and damage the system Incomplete flarin...

Page 8: ...s that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal insulation O D 1 2 inch 12 7mm O D 1 4 inch 6 4mm I D 0 551 0 630 inch 14 16mm I D 0 315 0 393 inch 8 10mm Minimum b...

Page 9: ... feed through wall hole and then through the back of the indoor unit Pull them through the front side Bend the ends of tie wires upward for easier work in advance If the inter unit wire ends are to be stripped first bundle wire ends with adhesive tape 3 Press the bottom frame of the indoor unit with both hands to set it on the mounting plate hooks Make sure the wires do not catch on the edge of th...

Page 10: ...ng the drain hose through the back of the indoor unit 9 While exercising care so that the inter unit wire do not catch indoor unit press the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks Secure indoor unit to the mounting plate with indoor unit fixing screws 3 16 1 2 inch M4 12mm Right bottom piping Right side piping Right back piping Bind coolant...

Page 11: ...d wires stranded wires extension cords or starburst connections as they may cause overheating electrical shock or fire Do not use locally purchased electrical parts inside the product Do not branch the power for the drain pump etc from the terminal block Doing so may cause electric shock or fire When carrying out wiring connection take care not to pull at the conduit Do not connect the power wire ...

Page 12: ...y to the drain hose attached to the indoor unit as with embedded piping work use any commercially available drain socket nominal diameter 1 2 inch 13mm as a joint The drain hose should be inclined downward No trap is permitted Do not put the end of the hose in water Indoor unit drain hose φ11 16 φ18mm Extension drain hose Heat insulation tube field supply Drain hose supplied with the indoor unit C...

Page 13: ...n its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Test items Symptom diagnostic display on RC Check Indoor and out...

Page 14: ... 1104 HT 3P276866 2D M10B203A Two dimensional bar code is a code for manufacturing 00_CV_3P276866 2D fm Page 2 Friday February 18 2011 4 21 PM ...

Reviews: