6 Maintenance and service

Operation manual

11

FTXM20~71N2V1B
Daikin room air conditioner
3P485919-8K – 2018.09

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

NOTICE

Maintenance  MUST  be  done  by  an  authorized  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  off.  Otherwise,  an
electric shock and injury may result.

WARNING

To prevent electric shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

WARNING

Be careful with ladders when working in high places.

6.2

To clean the indoor unit and user
interface

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

6.3

To clean the front panel

1

Clean the front panel with a soft cloth. If it is difficult to remove
stains, use water or a neutral detergent.

6.4

To remove the front panel

1

Hold the front panel by the panel tabs on both sides and open
it.

a

a

Panel tabs

2

Remove  the  front  panel  by  sliding  it  to  the  left  or  the  right  and
pulling it toward you.

Result: 

The front panel shaft on 1 side will be disconnected.

3

Disconnect  the  front  panel  shaft  on  the  other  side  in  the  same
manner.

a

a

Front panel shaft

6.5

About the air filters

Operating the unit with dirty filters means that the filter:

▪ CANNOT deodorize the air,

▪ CANNOT clean the air,

▪ poor heating/cooling,

▪ causes odour.

Summary of Contents for FTXM20N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner CTXM15N2V1B FTXM20N2V1B FTXM25N2V1B FTXM35N2V1B FTXM42N2V1B FTXM50N2V1B FTXM60N2V1B FTXM71N2V1B ...

Page 2: ...4 11 1 Precautions when using the wireless adapter 10 4 11 2 To install the Daikin Online Controller application 10 5 Energy saving and optimum operation 10 6 Maintenance and service 10 6 1 Overview Maintenance and service 10 6 2 To clean the indoor unit and user interface 11 6 3 To clean the front panel 11 6 4 To remove the front panel 11 6 5 About the air filters 11 6 6 To clean the air filters ...

Page 3: ...r interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust on the signal transmitter or receiver will reduce sensitivity Wipe off dust with a soft cloth Fluorescent lights Signal communication might be disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the othe...

Page 4: ...e reference position 4 Operation 4 1 Operation range Use the system in the following temperature and humidity ranges for safe and effective operation In combination with outdoor unit RZAG Cooling and drying a Heating a Outdoor temperature 20 52 C DB 20 24 C DB 21 18 C WB Indoor temperature 17 38 C DB 12 28 C WB 10 27 C DB Indoor humidity 80 b In combination with outdoor units RXM71N 2MXM 3MXM 4MXM...

Page 5: ...10 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 4 3 Airflow rate 1 Press to choose 5 airflow rate levels from to Automatic operation Indoor unit quiet operation When the airflow is set to the noise from the unit will be reduced INFORMATION If the unit reach the temperature...

Page 6: ...d to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The last selected function takes priority Detection sensitivity Changes according to location the number of persons in the room temperature range etc Detection mistakes The sensor may mistakenly detect pets sunlight m...

Page 7: ...nerated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharge may stop temporarily to prevent ozone smell 4 8 1 To start stop Flash Streamer operation 1 Press Result is displayed on the LCD and the air in the room is cleaned 2 To stop operation press Result disappears from the LCD and operation st...

Page 8: ... 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time can be set for each day Note Be sure to aim the user interface at the indoor unit and check for a receiving tone when setting the Weekly timer operation INFORMATION The clock MUST be set correctly before using any ...

Page 9: ...an confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservation number to be confirmed and check the reservation details Note To change the reservation setting refer to 4 10 1 To set Weekly timer operation on page 8 3 Press to exit the confirmation mode 4 10 ...

Page 10: ...lowing precautions to ensure the system operates properly Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Ventilate often Extended use requires special attention to ventilation Keep doors and windows closed If the doors and windows remain open air will flow out of your room causing a decrease in the cooling or heating effect Be careful NOT to cool ...

Page 11: ... the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fins are sharp and could result in cutting injuries WARNING Be careful with ladders when working in high places 6 2 To clean the indoor unit and user i...

Page 12: ...ir filters in the shade It is recommended to clean the air filters every 2 weeks 6 7 To clean the titanium apatite deodorizing filter INFORMATION Clean the filter with water every 6 months 1 Remove the titanium apatite deodorizing filter from the tabs class 15 42 or all 4 claws class 50 71 Class 15 42 Class 50 71 a Claw 2 Remove the dust from the filter with a vacuum cleaner 3 Soak the filter for ...

Page 13: ... power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer The system MUST be repaired by a qualified service person Malfunction Measure If a safety device such as a fuse a breaker or an earth leakage breaker frequently actuates or the ON OFF switch does NOT properly work Turn OFF the main pow...

Page 14: ......

Page 15: ......

Page 16: ...3P485919 8K 2018 09 Copyright 2018 Daikin ...