background image

5 Energy saving and optimum operation

Operation manual

10

FTXM20~71N2V1B

Daikin room air conditioner

3P485919-8K – 2018.09

▪ Smartphone,  tablet  or  another  smart  device  with  one  of  the

following operating systems:

▪ Android 4.0.3 or later

▪ iOS 7.1.2 or later

▪ Internet line and communication device, such as a modem, router,

etc.

▪ Wireless LAN access point

▪ Installed free 

Daikin Online Controller

 application

4.11.1

Precautions when using the wireless
adapter

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

4.11.2

To install the Daikin Online Controller
application

1

Open:

▪ Google Play for appliances using Android.
▪ App Store for appliances using iOS.

2

Search for 

Daikin Online Controller

.

3

Follow the directions on the screen to install.

5

Energy saving and optimum
operation

INFORMATION

▪ Even if the unit is turned OFF, it consumes electricity.

▪ When the power turns back on after a power break, the

previously selected mode will be resumed.

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

WARNING

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays. Doing so may result in
a fire.

Observe  the  following  precautions  to  ensure  the  system  operates
properly.

▪ Prevent  direct  sunlight  from  entering  a  room  during  cooling

operation by using curtains or blinds.

▪ Ventilate  often.  Extended  use  requires  special  attention  to

ventilation.

▪ Keep doors and windows closed. If the doors and windows remain

open,  air  will  flow  out  of  your  room  causing  a  decrease  in  the
cooling or heating effect.

▪ Be  careful  NOT  to  cool  or  heat  too  much.  To  save  energy,  keep

the temperature setting at a moderate level.

▪ NEVER place objects near the air inlet or the air outlet of the unit.

Doing  so  may  cause  a  reduced  heating/cooling  effect  or  stop
operation.

▪ Turn off the main power supply switch to the unit when the unit is

NOT  used  for  longer  periods  of  time.  If  the  main  power  supply
switch  is  on,  the  unit  consumes  electricity.  Before  restarting  the
unit,  turn  on  the  main  power  supply  switch  6  hours  before
operation to ensure smooth running.

▪ Condensation  may  form  if  the  humidity  is  above  80%  or  if  the

drain outlet gets blocked.

▪ Adjust  the  room  temperature  properly  for  a  comfortable

environment.  Avoid  excessive  heating  or  cooling.  Notice  that  it
may  take  some  time  for  the  room  temperature  to  reach  the  set
temperature. Consider using the timer setting options.

▪ Adjust the air flow direction to avoid cool air from gathering on the

floor  or  warm  air  against  the  ceiling.  (Up  during  cooling  or  dry
operation to the ceiling and down during heating operation.)

▪ Avoid direct air flow to room inhabitants.

▪ Operate  the  system  within  the  recommended  temperature  range

(26~28°C for cooling and 20~24°C for heating) to save energy.

6

Maintenance and service

6.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

In  Europe,  the 

greenhouse  gas  emissions

  of  the  total

refrigerant charge in the system (expressed as tonnes CO

2

equivalent) is used to determine the maintenance intervals.
Follow the applicable legislation.

Formula  to  calculate  the  greenhouse  gas  emissions:

GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000

Please contact your installer for more information.

Summary of Contents for FTXM20N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner CTXM15N2V1B FTXM20N2V1B FTXM25N2V1B FTXM35N2V1B FTXM42N2V1B FTXM50N2V1B FTXM60N2V1B FTXM71N2V1B ...

Page 2: ...4 11 1 Precautions when using the wireless adapter 10 4 11 2 To install the Daikin Online Controller application 10 5 Energy saving and optimum operation 10 6 Maintenance and service 10 6 1 Overview Maintenance and service 10 6 2 To clean the indoor unit and user interface 11 6 3 To clean the front panel 11 6 4 To remove the front panel 11 6 5 About the air filters 11 6 6 To clean the air filters ...

Page 3: ...r interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust on the signal transmitter or receiver will reduce sensitivity Wipe off dust with a soft cloth Fluorescent lights Signal communication might be disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the othe...

Page 4: ...e reference position 4 Operation 4 1 Operation range Use the system in the following temperature and humidity ranges for safe and effective operation In combination with outdoor unit RZAG Cooling and drying a Heating a Outdoor temperature 20 52 C DB 20 24 C DB 21 18 C WB Indoor temperature 17 38 C DB 12 28 C WB 10 27 C DB Indoor humidity 80 b In combination with outdoor units RXM71N 2MXM 3MXM 4MXM...

Page 5: ...10 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 4 3 Airflow rate 1 Press to choose 5 airflow rate levels from to Automatic operation Indoor unit quiet operation When the airflow is set to the noise from the unit will be reduced INFORMATION If the unit reach the temperature...

Page 6: ...d to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The last selected function takes priority Detection sensitivity Changes according to location the number of persons in the room temperature range etc Detection mistakes The sensor may mistakenly detect pets sunlight m...

Page 7: ...nerated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharge may stop temporarily to prevent ozone smell 4 8 1 To start stop Flash Streamer operation 1 Press Result is displayed on the LCD and the air in the room is cleaned 2 To stop operation press Result disappears from the LCD and operation st...

Page 8: ... 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time can be set for each day Note Be sure to aim the user interface at the indoor unit and check for a receiving tone when setting the Weekly timer operation INFORMATION The clock MUST be set correctly before using any ...

Page 9: ...an confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservation number to be confirmed and check the reservation details Note To change the reservation setting refer to 4 10 1 To set Weekly timer operation on page 8 3 Press to exit the confirmation mode 4 10 ...

Page 10: ...lowing precautions to ensure the system operates properly Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Ventilate often Extended use requires special attention to ventilation Keep doors and windows closed If the doors and windows remain open air will flow out of your room causing a decrease in the cooling or heating effect Be careful NOT to cool ...

Page 11: ... the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fins are sharp and could result in cutting injuries WARNING Be careful with ladders when working in high places 6 2 To clean the indoor unit and user i...

Page 12: ...ir filters in the shade It is recommended to clean the air filters every 2 weeks 6 7 To clean the titanium apatite deodorizing filter INFORMATION Clean the filter with water every 6 months 1 Remove the titanium apatite deodorizing filter from the tabs class 15 42 or all 4 claws class 50 71 Class 15 42 Class 50 71 a Claw 2 Remove the dust from the filter with a vacuum cleaner 3 Soak the filter for ...

Page 13: ... power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer The system MUST be repaired by a qualified service person Malfunction Measure If a safety device such as a fuse a breaker or an earth leakage breaker frequently actuates or the ON OFF switch does NOT properly work Turn OFF the main pow...

Page 14: ......

Page 15: ......

Page 16: ...3P485919 8K 2018 09 Copyright 2018 Daikin ...

Reviews: