background image

7

English

Indoor Unit Installation

3-2. Left-side, left-back, or left-bottom piping

1) Attach the drain hose to the underside of the refrigerant pipes 

with adhesive vinyl tape.

2) Be sure to connect the drain hose to the drain port in place of 

a drain plug.

3) Shape the refrigerant pipes along the pipe 

path marking on the mounting plate.

4) Pass the drain hose and refrigerant pipes 

through the wall hole, then set the indoor 
unit on mounting plate hooks, using the 

markings at the top of the indoor unit as 

a guide.

5) Pull in the inter-unit wire.
6) Connect the inter-unit pipes.

7) Wrap the refrigerant pipes and drain hose together with insulation tape as 

shown in the figure on the right (in case of setting the drain hose through 
the back of the indoor unit).

8) While exercising care so that the inter-unit wire does not catch indoor unit, 

press the bottom edge of indoor unit with both hands until it is firmly caught 
by the mounting plate hooks. Secure indoor unit to the mounting plate with 
indoor unit fixing screws (M4 × 12L).

3-3. Wall embedded piping

Follow the instructions given under left-side, left-back, or left-bottom piping.
1) Insert the drain hose to this depth so it won’t be pulled out of the drain pipe.

How to replace the drain plug and drain hose

• Replacing onto the left side

1) Remove the insulation fixing screw on the 

right and remove the drain hose.

2) Remove the drain plug on the left side and 

attach it to the right side.

3) Insert the drain hose and tighten with 

included insulation fixing screw.
* (Forgetting to tighten this may cause 
   water leakages.)

Drain hose attachment position

* The drain hose is on the back of the unit.

Front side of unit

Attachment on the right side (factory default)

Attachment on the left side

Drain hose

Drain hose

Insulation 
fixing screw

Insulation 
fixing screw

Left side

Right side

Remove pipe port cover here for left-bottom piping.

Remove pipe 
port cover 
here for left-
side piping.

Left-bottom piping

Left-side 
piping

Left-back 
piping

How to set drain plug

No gap.

Do not apply lubricating 
oil (refrigerant oil) to the 
drain plug when inserting it.
The application of lubrication 
oil to the drain plug will deteriorate 
the plug and cause drain leakage 
from the plug.

Insert a hexagonal wrench (4mm).

Drain 
hose

Caulk this hole 
with putty or 
caulking material.

Bind with adhesive 
vinyl tape.

Mounting plate

Wrap insulating tape around the 
bent portion of refrigerant pipes. 
Overlap at least half the width of 
the tape with each turn.

Refrigerant 
pipes

Drain hose

Bottom frame

Indoor unit fixing screw
(M4 × 12L) (2 locations)

Mounting 
plate

Inter-unit wire

Inner wall

Vinyl chloride 
drain pipe 
(VP-30)

Drain hose

50mm 
or more

Insert drain hose 
to this depth so 
it won’t be pulled 
out of drain pipe.

Outer wall

Summary of Contents for FTXLS25K3V1B

Page 1: ...DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series MODELS FTXLS25K3V1B FTXLS35K3V1B DAIKIN...

Page 2: ......

Page 3: ...ivamente por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer positivo de B...

Page 4: ...cause overheating electric shocks or fire Make sure that all wiring is secured the specified wires are used and that there is no strain on the terminal connections or wires Improper connections or se...

Page 5: ...emote controller signals are properly received by the indoor unit within 7m CAUTION Do not install the air conditioner at any place where there is a danger of flammable gas leakage In the event of a g...

Page 6: ...grille there are 3 upper hooks Lightly pull the front grille toward you with one hand and push down on the hooks with the fingers of your other hand When there is no work space because the unit is cl...

Page 7: ...move the front grille Opening the service lid The service lid is removable 1 Remove the service lid screw 2 Pull out the service lid diagonally down in the direction of the arrow 3 Pull down The mount...

Page 8: ...o the hole 3 Insert a wall cover into wall pipe 4 After completing refrigerant piping wiring and drain piping caulk pipe hole gap with putty 3 Installing the indoor unit In the case of bending or curi...

Page 9: ...late hooks by using the markings at the top of the indoor unit as a guide 4 Open the front panel then open the service lid Refer to preparation before installation 5 Pass the inter unit wire from the...

Page 10: ...onto the left side 1 Remove the insulation fixing screw on the right and remove the drain hose 2 Remove the drain plug on the left side and attach it to the right side 3 Insert the drain hose and tig...

Page 11: ...R T THERMISTOR DS DIPSWITCH RC RECEIVER E H HEATER S C LIMITSWITCH F U FU FORCHARACTERISTICS REFERTOPCBINSIDEYOURUNIT FUSE S L FLOATSWITCH FG CONNECTOR FRAMEGROUND S NPH PRESSURESENSOR HIGH H HARNESS...

Page 12: ...nnect the power wire to the indoor unit Doing so may cause electric shock or fire 5 When connecting to an HA system Wired remote controller central remote controller etc 1 Remove the metal plate elect...

Page 13: ...trical wiring covers as shown below 1 Lean the metal plate electrical wiring cover as shown in the figure and attach tab 1 on the lower side to the electrical wiring box 2 Attach tab 2 on the lower si...

Page 14: ...properly made WARNING Do not use mineral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for pre...

Page 15: ...frigerant gas pipe s surface temperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide ins...

Page 16: ...stem will restore the original operation mode when the circuit breaker is opened again 2 Test items If the is not displayed make sure not to cut the switching jumper J8 for cooling operation when cutt...

Page 17: ......

Page 18: ...3P377527 3D 2017 03 Copyright 2015 Daikin...