background image

4 Before operation

Operation manual

6

FTXF20~42E5V1B

Daikin room air conditioner

3P520336-19V – 2022.09

Icon

Description

Operation mode = Heating

Operation mode = Cooling

Operation mode = Fan only

Powerful operation is active

Econo operation is active

Operation is active

The indoor unit receives a signal
from the user interface

Current temperature setting

Airflow rate = Automatic

Airflow rate = Indoor unit quiet

Airflow rate = High

Airflow rate = Medium high

Airflow rate = Medium

Airflow rate = Medium low

Airflow rate = Low

Comfort operation is active

Auto vertical swing is active

ON timer is active

OFF timer is active

3.2.3

To operate the wireless remote control

a

a

Infrared signal receiver

1

Aim the signal transmitter at the infrared signal receiver on the
indoor unit (maximum distance for communication is 7 m).

Result: 

When  the  indoor  unit  receives  a  signal  from  the  wireless

remote control, you will hear a sound:

Sound

Description

Beep-beep

Operation starts.

Beep

Setting changes.

Long beep

Operation stops.

4

Before operation

4.1

To mount the wireless remote
control holder

b

c

a

a

Wireless remote control

b

Screws (field supply)

c

Wireless remote control holder

1

Choose a place where the signals reach the unit.

2

Attach the holder with screws to the wall or a similar location.

3

Hang the wireless remote control on the holder.

4.2

To insert the batteries

The batteries will last for about 1 year.

1

Remove the back cover.

2

Insert both batteries at once.

3

Put the cover back.

2

3

1

AAA.LR03

4.3

To turn on the power supply

1

Turn the circuit breaker on.

Result: 

The  flap  of  the  indoor  unit  will  open  and  close  to  set  the

reference position.

5

Operation

INFORMATION

The  indoor  unit  is  delivered  with  the  wireless  remote
control  as  the  user  interface.  This  manual  describes  only
operation with this user interface. If another user interface
is  connected,  refer  to  the  operation  manual  of  the
connected user interface.

5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Summary of Contents for FTXF25E5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20E5V1B FTXF25E5V1B FTXF35E5V1B FTXF42E5V1B...

Page 2: ...s can give off odours 12 8 1 9 Symptom The outdoor fan rotates while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1...

Page 3: ...ns a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteries are...

Page 4: ...l shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with ladders when working in hig...

Page 5: ...used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote co...

Page 6: ...nd Description Beep beep Operation starts Beep Setting changes Long beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder 2 b c a a Wireless remote control b Screws f...

Page 7: ...nd set the temperature when you want to Heat up or cool down a room Blow air in a room without heating or cooling Decrease the humidity in a room What The system operates differently depending on the...

Page 8: ...Be careful when adjusting the louvers Inside the air outlet a fan is rotating at high speed The movable range of the flap varies according to the operation mode The flap will stop at the upper positi...

Page 9: ...pressor If power consumption is already low Econo operation will NOT further reduce power consumption To start stop Econo operation 1 Press to start Result is displayed on the LCD 2 Press to stop Resu...

Page 10: ...ake some time for the room temperature to reach the set temperature Consider using the timer setting options Adjust the air flow direction to avoid cool air from gathering on the floor or warm air aga...

Page 11: ...to remove stains use water or a neutral detergent 7 4 About the air filters Operating the unit with dirty filters means that the filter CANNOT deodorise the air CANNOT clean the air poor heating cooli...

Page 12: ...re 8 1 4 Symptom A whistling sound is heard This sound is generated by the refrigerant flowing during defrost operation 8 1 5 Symptom A clicking sound during operation or idle time is heard This sound...

Page 13: ...oor unit Error code Description 4 way valve abnormality Outdoor unit PCB abnormality Overload activation compressor overload Compressor lock DC fan lock Input power overcurrent Discharge pipe temperat...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 19V 2022 09 Copyright 2...