background image

5 Operation

Operation manual

9

FTXF20~42E5V1B
Daikin room air conditioner
3P520336-19V – 2022.09

Result: 

The  flap  position  will  change, 

  is  displayed  on  the

LCD, and the airflow rate is set to automatic.

Mode

Position of flap…

Cooling/Drying

Up

Heating

Down

Note: 

Comfort airflow operation is NOT available in Fan only mode.

2

Press 

 to stop.

Result: 

The  flap  will  return  to  the  position  from  before  the  Comfort

airflow mode; 

 disappears from the LCD.

5.3.5

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

INFORMATION

Powerful operation CANNOT be used together with Econo
and  Comfort  airflow  operation.  The  last  selected  function
takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

To start/stop Powerful operation

1

Press 

 to start.

Result: 

  is  displayed  on  the  LCD.  Powerful  operation  runs

for 20 minutes; after that, operation returns to the previously set
mode.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

Note:

 Powerful operation can be set only when the unit is running. If

you press 

 or if you change operation mode, operation will

be cancelled; 

 disappears from the LCD.

5.3.6

Econo operation

This  is  a  function  which  enables  efficient  operation  by  limiting  the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

To start/stop Econo operation

1

Press 

 to start.

Result: 

 is displayed on the LCD.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

5.3.7

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner off/on at night or in the morning. You can also use OFF
timer and ON timer in combination.

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the wireless remote control.

To start/stop ON timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD and the timer lamp lights

up.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 12 hours.

2

Press 

 to stop.

Result: 

  disappears  from  the  LCD  and  the  timer  lamp

goes off.

To start/stop OFF timer operation

INFORMATION

When you set the ON/OFF timer, the time setting is stored
in  the  memory.  The  memory  will  be  reset  when  the
wireless remote control batteries are replaced.

Night set mode

When  the  OFF  timer  is  set,  the  air  conditioner
automatically  adjusts  the  temperature  setting  (0.5°C  up  in
cooling,  2.0°C  down  in  heating)  to  prevent  excessive
cooling/heating  and  ensure  a  comfortable  sleeping
temperature.

Use  this  feature  if  the  unit  is  operating  and  you  want  to  stop
operation after a certain time.

1

Press 

 to start.

Result: 

 is displayed on the LCD and the timer lamp lights

up.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 9 hours.

2

Press 

 to stop.

Result: 

  disappears  from  the  LCD  and  the  timer  lamp

goes off.

To combine OFF timer and ON timer

1

To  set  the  timers,  refer  to 

"To  start/stop  OFF  timer

operation"

 [

4

 9] and 

"To start/stop ON timer operation"

 [

4

 9].

Result: 

 and 

 are displayed on the LCD.

2

Example of what is displayed on the LCD if you combine the 2

timers: 

Summary of Contents for FTXF25E5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20E5V1B FTXF25E5V1B FTXF35E5V1B FTXF42E5V1B...

Page 2: ...s can give off odours 12 8 1 9 Symptom The outdoor fan rotates while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1...

Page 3: ...ns a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteries are...

Page 4: ...l shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with ladders when working in hig...

Page 5: ...used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote co...

Page 6: ...nd Description Beep beep Operation starts Beep Setting changes Long beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder 2 b c a a Wireless remote control b Screws f...

Page 7: ...nd set the temperature when you want to Heat up or cool down a room Blow air in a room without heating or cooling Decrease the humidity in a room What The system operates differently depending on the...

Page 8: ...Be careful when adjusting the louvers Inside the air outlet a fan is rotating at high speed The movable range of the flap varies according to the operation mode The flap will stop at the upper positi...

Page 9: ...pressor If power consumption is already low Econo operation will NOT further reduce power consumption To start stop Econo operation 1 Press to start Result is displayed on the LCD 2 Press to stop Resu...

Page 10: ...ake some time for the room temperature to reach the set temperature Consider using the timer setting options Adjust the air flow direction to avoid cool air from gathering on the floor or warm air aga...

Page 11: ...to remove stains use water or a neutral detergent 7 4 About the air filters Operating the unit with dirty filters means that the filter CANNOT deodorise the air CANNOT clean the air poor heating cooli...

Page 12: ...re 8 1 4 Symptom A whistling sound is heard This sound is generated by the refrigerant flowing during defrost operation 8 1 5 Symptom A clicking sound during operation or idle time is heard This sound...

Page 13: ...oor unit Error code Description 4 way valve abnormality Outdoor unit PCB abnormality Overload activation compressor overload Compressor lock DC fan lock Input power overcurrent Discharge pipe temperat...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 19V 2022 09 Copyright 2...

Reviews: