2
English
Safety Precautions
Accessories
–
Choosing an Installation Site
Before choosing the installation site, obtain user approval.
1.
Indoor unit
• The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air inlet and air outlet have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote
controller range,
8) the unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound),
9) no laundry equipment is located.
2.
Wireless remote controller
• Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are properly received
by the indoor unit (within 7m).
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage
and insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial and household use by lay persons.
• Sound pressure level is less than 70 dB(A).
• Installation shall be done by an installer, the choice of materials and installation shall comply with the applicable legislation.
In Europe the EN378 is the applicable standard that shall be used.
Mounting plate
1
Remote controller holder
1
Operation manual
1
Titanium apatite photocatalytic
air-purifying filter
2
Dry battery AAA. LR03
(alkaline)
2
Installation manual
1
Wireless remote controller
1
Indoor unit fixing screw
(M4 × 12L)
2
Indoor unit
A
H
A
D
G
B
E
H
C
F
3PEN393185-9T.book Page 2 Monday, September 5, 2016 1:34 PM