background image

English

3

Englis

h

Preparation before Installation

1.

Removing and installing the front panel

• Removal method

1) Place your fingers in the indentations on the main unit (one each on the 

left and right sides), and open the front panel until it stops.

2) Continue to open the front panel further while sliding the panel to the 

right and pulling it toward you in order to disengage the front panel shaft 
on the left side. To disengage the front panel shaft on the right side, slide 
the panel to the left while pulling it toward you.

• Installation method

Align the tabs of the front panel with the grooves, and push all the way 
in. Then close slowly. Push the centre of the lower surface panel firmly 
to engage the tabs.

2.

Removing and installing the front grille

• Removal method

1) Remove the front panel to remove the air filter.
2) Remove the 3 screws from the front grille.
3) In front of the 

 mark of the front grille, there are 3 upper hooks.

Lightly pull the front grille toward you with one hand, and push down on 
the hooks with the fingers of your other hand.

When there is no work space because the unit is close to ceiling

 CAUTION

• Be sure to wear protection gloves.

Place both hands under the centre of the front grille, and while pushing up, pull it toward you.

• Installation method

1) Install the front grille and firmly engage the upper hooks (3 locations).
2) Install 3 screws of the front grille.
3) Install the air filter and then mount the front panel.

3.

How to set the different addresses

When 2 indoor units are installed in one room, the 2 wireless remote
controllers can be set for different addresses. Change the address
setting of one of the two units.
When cutting the jumper be careful not to damage any of the
surrounding parts.

1) Remove the battery cover on the remote controller 

and cut the address jumper.

2) Press

,

and

at the same time.

3) Press

, select

, press

.

(The indoor unit OPERATION lamp will blink for
about 1 minute.)

4) Press the indoor unit ON/OFF switch while the

OPERATION lamp is blinking.

          

Indentations on 
the main unit

Upper hook

mark area

(3 locations)

Push 
down.

Upper hook

Front panel shaft

1) Push up.

2) Pull toward you.

Jumper

ADDRESS

EXIST

1

CUT

2

Jumper

ON/OFF

Indoor unit 

ON/OFF 

switch

OPERATION 

lamp

• If setting could not be carried out completely while the 

OPERATION lamp was blinking, carry out the setting pro-

cess once again from the beginning.
• After setting is complete, pressing

for about 5 sec-

onds will cause the remote controller to return to the previ-

ous display.

3PEN393185-9T.book  Page 3  Monday, September 5, 2016  1:34 PM

Summary of Contents for FTX25KNV1B

Page 1: ...CONDITIONER INSTALLATION MANUAL R410A Split Series English Deutsch Fran ais Nederlands Espa ol Italiano E Portugues Pycc T rk e MODELS FTX25KNV1B FTX35KNV1B 3PEN393185 9T book Page 1 Monday September...

Page 2: ...vamente por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer positivo de B...

Page 3: ...ic shocks or fire Make sure that all wiring is secured the specified wires are used and that there is no strain on the terminal connections or wires Improper connections or securing of wires may resul...

Page 4: ...r at any place where there is a danger of flammable gas leakage In the event of a gas leakage build up of gas near the air conditioner may cause a fire to break out While following the instructions in...

Page 5: ...ands under the centre of the front grille and while pushing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install 3 screws of the...

Page 6: ...ctor and pull the harness as shown in the figure 3 Replace the electrical wiring cover as it was and pull the harness around as shown in the figure Removal method of metal plate electrical wiring cove...

Page 7: ...the marked area at the lower part of the front grille to release the hooks If it is difficult to release remove the front grille 30mm or more from ceiling Front panel 50mm or more from walls on both...

Page 8: ...a wall cover into wall pipe 4 After completing refrigerant piping wiring and drain piping caulk pipe hole gap with putty 3 Installing the indoor unit In the case of bending or curing refrigerant pipes...

Page 9: ...arkings at the top of the indoor unit as a guide 4 Open the front panel then open the service lid Refer to preparation before installation 5 Pass the inter unit wire from the outdoor unit through the...

Page 10: ...insulation fixing screw on the right and remove the drain hose 2 Remove the drain plug on the left side and attach it to the right side 3 Insert the drain hose and tighten with included insulation fi...

Page 11: ...DIPSWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FORCHARACTERISTICS REFERTOPCBINSIDEYOURUNIT FUSE S C LIMITSWITCH FG CONNECTOR FRAMEGROUND S L FLOATSWITCH H HARNESS S NPH PRESSURESENSOR HIGH H P...

Page 12: ...ay cause overheating electri cal shock or fire Do not use locally purchased electrical parts inside the product Do not branch the power for the drain pump etc from the terminal block Doing so may caus...

Page 13: ...ral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for previous installations Only use parts wh...

Page 14: ...mperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 U...

Page 15: ...To stop the operation press Some of the functions cannot be used in the trial operation mode The air conditioner draws a small amount of power in its standby mode If the system is not to be used for s...

Page 16: ...3P393185 9T 2016 09 Copyright 2016 Daikin 3PEN393185 9T book Page 1 Monday September 5 2016 1 34 PM...

Reviews: