background image

3

English

Installation Tips

1.

Removing and installing front panel.

• Removal method

1) Place your fingers in the indentations on the main unit (one each on the 

left and right sides), and open the panel until it stops.

2) Continue to open the front panel further while sliding the panel to the right 

and pulling it toward you in order to disengage the rotating shaft on the 
left side. To disengage the rotating shaft on the right side, slide the panel 
to the left while pulling it toward you.

• Installation method

Align the tabs of the front panel with the grooves, and push all the way in. Then 
close slowly. Push the center of the lower surface of the panel firmly to engage the 
tabs.

2.

Removing and installing front grille.

• Removal method

1) Remove front panel to remove the air filter.
2) Remove the screws (2) from the front grille.
3) In front of the 

{{{

 mark of the front grille, there are 3 upper hooks. 

Lightly pull the front grille toward you with one hand, and push down on 
the hooks with the fingers of your other hand.

When there is no work space because the unit is close to ceiling

CAUTION

Be sure to wear protection gloves.

Place both hands under the center of the front grille, and while pushing up, pull it toward you.

• Installation method

1) Install the front grille and firmly engage the upper hooks (3 locations).
2) Install 2screws of the front grille.
3) Install the air filter and then mount the front panel.

3.

How to set the different addresses.

When two indoor units are installed in one room, the two wireless remote controllers 
can be set for different addresses.
1) In the same way as when connecting to an HA system, remove the metal plate 

electrical wiring cover.

2) Cut the address jumper (JA) on the printed circuit board.
3) Cut the address jumper (J4) in the remote controller.

Indentations on 
the main unit

Push the rotating 
shaft of the front 
panel into the groove.

Rotating shaft

¡¡¡ mark area

(3 locations)

Upper hook

Lightly pull the front 
grille toward you with 
one hand, and push 
down on the hooks with 
the fingers of your other 
hand. (3 locations)

Push
down.

Upper hook

Upper hook

1) Push up.

2) Pull toward you.

ADDRESS

EXIST
 CUT

1
2

JA

JA

ADDRESS

J4

EXIST
 CUT

1
2

J4

01_EN_3P207973-1D.fm  Page 3  Friday, September 4, 2009  10:44 AM

Summary of Contents for FTX20GV1B

Page 1: ...e Installation manual R410A Split series Montaj k lavuzlar R410A Split serisi Installationsanleitung Split Baureihe R410A Manuel d installation S rie split R410A Montagehandleiding R410A Split systee...

Page 2: ...TK25GV1B FTK35GV1B FTX20JV1B FTX25JV1B FTX35JV1B DAIKIN INDUSTRIES LTD Shinri Sada Manager Quality Control Department 11th of Sep 2009 Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC...

Page 3: ...lamping may cause terminal overheating or fire After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels Ins...

Page 4: ...ctronic ignition type fluorescent lamps inverter or rapid start type as they may shorten the remote control range 8 the unit is at least 1 metre away from any television or radio set unit may cause in...

Page 5: ...When there is no work space because the unit is close to ceiling CAUTION Be sure to wear protection gloves Place both hands under the center of the front grille and while pushing up pull it toward you...

Page 6: ...pe hole gap with putty Mounting plate Clip Mark rear side Bottom frame Front grille How to attach the indoor unit Hook the claws of the bottom frame to the mounting plate If the claws are difficult to...

Page 7: ...nting plate retention spots and Dimensions 770 Use tape measure as shown Position the end of a tape measure at Keep here the piece cut out from the unit for piping Liquid pipe end Gas pipe end The rem...

Page 8: ...pipes and drain hose together with an insulation tape 3 Pass the drain hose and refrigerant pipes through the wall hole then set the indoor unit on the mounting plate hooks by using the markings at t...

Page 9: ...ove the drain hose 2 Reattach the insulation fixing screw on the right as it was Forgetting to attach this may cause water leakages 3 Remove the drain plug on the left side and attach it to the right...

Page 10: ...n be performed with the electrical component box attached Omit the steps involved with removing and installing the electrical component box in order to perform the work more efficiently 5 1 Remove the...

Page 11: ...omponent box 2 Route the connection cord as shown in Figure 3 5 8 Install the indoor unit electrical component box in its original position 1 Install the flap 2 Install the electrical component box 1...

Page 12: ...vent mineral oil from getting into the system as this would reduce the lifetime of the units 3 Never use piping which has been used for previous installations Only use parts which are delivered with t...

Page 13: ...035 to 0 045 kcal mh C Refrigerant gas pipe s surface temperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid...

Page 14: ...small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit break...

Page 15: ...0911 HT 3P207973 1D M07B030C Two dimensional bar code is a code for manufacturing 00_CV_3P207973 1D fm Page 2 Friday September 4 2009 10 41 AM...

Reviews: