Trial Operation and Testing
1�
Trial operation and testing
•
Trial operation should be carried out in either COOL or HEAT operation.
1-1�
Measure the supply voltage and make sure that it is within the specified range.
1-2� In COOL operation, select the lowest programmable temperature;
in HEAT operation, select the highest programmable temperature�
1-3� Carry out the trial operation following the instructions in the operation manual to
ensure that all functions and parts, such as the movement of the flap, are working
properly�
• To protect the air conditioner, restart operation is disabled for 3 minutes after the system has been turned off.
1-4� After trial operation is complete, set the temperature to a normal level (78°F to 82°F
(26°C to 28°C) in COOL operation, 68°F to 75°F (20°C to 24°C) in HEAT operation)�
• When operating the air conditioner in COOL operation in winter,
or HEAT operation in summer, set it to the trial operation mode using
the following method.
1) Press
,
and
at the same time.
2) Press
, then select , press
.
3) Press
or
to turn on the system.
• Trial operation will stop automatically after about 30 minutes.
To stop the operation, press
.
• Some of the functions cannot be used in the trial operation mode.
HEAT PUMP model
• The air conditioner draws a small amount of power in its standby mode. If the system is not to be used for some time
after installation, shut off the circuit breaker to eliminate unnecessary power consumption.
• If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation mode
when the circuit breaker is turned on again.
2�
Test items
Test items
Symptom
Check
Indoor and outdoor units are installed securely.
Fall, vibration, noise
No refrigerant gas leaks.
Incomplete cooling/heating
function
Refrigerant gas and liquid pipes and indoor drain hose extension are
thermally insulated.
Water leakage
Draining line is properly installed.
Water leakage
System is properly grounded.
Electrical leakage
Only specified wires are used for all wiring, and all wires are connected
correctly.
No operation or burn damage
Indoor or outdoor unit’s air inlet or air outlet are unobstructed.
Incomplete cooling/heating
function
Stop valves are opened.
Incomplete cooling/heating
function
Indoor unit properly receives remote control commands.
No operation