WHEN THE NEED ARISES
WHEN THE NEED ARISES
Check again.
Please check again before calling a repair person�
Case
What to check
The air conditioner does not operate.
OPERATION lamp is off.
•
Hasn’t a breaker turned OFF or a fuse blown?
•
Isn’t it a power failure?
•
Are batteries set in the remote controller?
•
Is the timer setting correct?
OPERATION lamp blinks.
•
Turn off the power with the circuit breaker and restart
operation with the remote controller. If the OPERATION lamp
is still blinking, check the error code and consult your dealer�
Cooling effect is poor.
•
Are the air filters clean?
• Is there anything blocking the air inlet or air outlet of the
indoor unit or outdoor unit?
•
Is the temperature setting appropriate?
•
Are the windows and doors closed?
•
Are the airflow rate and the air direction set appropriately?
•
Are outdoor ambient temperature not in operation range?
• Is the unit set to the ECONO/MOLD PROOF/OUTDOOR
UNIT QUIET mode?
Page 15-18
Operation stops suddenly.
(OPERATION lamp blinks.)
•
Are the air filters clean?
• Is there anything blocking the air inlet or air outlet of the
indoor unit or outdoor unit?
•
Clean the air filters or take all obstacles away and turn the
breaker OFF� Then turn it ON again and try operating the air
conditioner with the remote controller. If the lamp still blinks,
call the service shop where you bought the air conditioner.
An abnormal functioning
happens during operation.
•
The air conditioner may malfunction with lightning or radio
waves. Turn the breaker OFF, turn it ON again and try
operating the air conditioner with the remote controller.
Notes on the operating conditions
•
The air conditioner always consumes a small amount of electricity even while it is not operating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn,
turn the breaker off�
•
Use the air conditioner in the following conditions.
MODE
Operating conditions
If operation is continued out of this range
COOL / DRY
Outdoor temperature : 19�4-46°C
Indoor temperature : 16-32°C
Indoor humidity : 80% max�
•
A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip�
• Operation outside this humidity or temperature range may cause a safety device to disable the
system�
27
01_EN_3P658678-13V_WEB.indd 27
14-Mar-23 12:02:28 PM
Summary of Contents for FTKQ09XV2S
Page 2: ...01_EN_3P658678 13V_WEB indd 2 14 Mar 23 12 01 52 PM...
Page 33: ...MEMO 31 01_EN_3P658678 13V_WEB indd 31 14 Mar 23 12 02 29 PM...
Page 34: ...MEMO 32 01_EN_3P658678 13V_WEB indd 32 14 Mar 23 12 02 29 PM...
Page 35: ...01_EN_3P658678 13V_WEB indd 33 14 Mar 23 12 02 29 PM...
Page 36: ...3P658678 13V_WEB SIAM DAIKIN SALES CO LTD 00_CV_3P658678 13V_WEB indd 2 24 Feb 23 8 50 41 AM...