WHEN THE NEED ARISES
WHEN THE NEED ARISES
NOTE
• A short beep and 2 consecutive beeps indicate non-corresponding codes�
• To cancel the code display, hold
down for about 5 seconds. The code display also clears if
no button is pressed for 1 minute�
Fault diagnosis by remote controller
In case the air conditioner is malfunctioning, you can check the error code via
the remote controller before consulting with service personnel and informing
them of the malfunction code�
1. When
is held down for about 5 seconds,
“
” blinks in the temperature display section.
2.
Press
repeatedly until a continuous beep is
produced.
•
The code indication changes as shown below, and notifies you with a
long beep�
CODE
MEANING
SYSTEM
00
NORMAL
UA
INDOOR-OUTDOOR UNIT COMBINATION FAULT
U0
REFRIGERANT SHORTAGE
U2
DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4
FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT
AND OUTDOOR UNIT)
INDOOR
UNIT
A1
INDOOR PCB DEFECTIVENESS
A5
HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6
FAN MOTOR FAULT
C4
FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9
FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR
UNIT
EA
COOLING-HEATING SWITCHING ERROR
E1
CIRCUIT BOARD FAULT
E5
OL STARTED
E6
FAULTY COMPRESSOR START UP
E7
DC FAN MOTOR FAULT
F3
HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6
HIGH PRESSURE CONTROL (IN COOLING)
F8
OPERATION HALT DUE TO COMPRESSOR INTERNAL
TEMPERATURE ABNORMALITY
H0
SENSOR FAULT
H6
OPERATION HALT DUE TO FAULTY POSITION
DETECTION SENSOR
H8
DC CURRENT SENSOR FAULT
H9
FAULTY SUCTION AIR TEMPERATURE SENSOR
J3
FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6
FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3
ELECTRICAL PARTS HEAT FAULT
L4
HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5
OUTPUT OVERCURRENT
P4
FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE
SENSOR
29
01_EN_3P658678-13V_WEB.indd 29
14-Mar-23 12:02:29 PM
Summary of Contents for FTKQ09XV2S
Page 2: ...01_EN_3P658678 13V_WEB indd 2 14 Mar 23 12 01 52 PM...
Page 33: ...MEMO 31 01_EN_3P658678 13V_WEB indd 31 14 Mar 23 12 02 29 PM...
Page 34: ...MEMO 32 01_EN_3P658678 13V_WEB indd 32 14 Mar 23 12 02 29 PM...
Page 35: ...01_EN_3P658678 13V_WEB indd 33 14 Mar 23 12 02 29 PM...
Page 36: ...3P658678 13V_WEB SIAM DAIKIN SALES CO LTD 00_CV_3P658678 13V_WEB indd 2 24 Feb 23 8 50 41 AM...