background image

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/products/ac/

All rights reserved

c

Warning

z

Daikin products are manufactured for export to numerous countries throughout the world. Prior to 
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this 
product conforms to the applicable standards, and is suitable for use, in the region where the product 
will be used. This statement does not purport to exclude, restrict or modify the application of any local 
legislation.

z

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. 
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

z

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or 
contractor to install those parts and accessories. Use of unauthorised parts and accessories or 
improper installation of parts and accessories can result in water or refrigerant leakage, electrical 
shock, fire or explosion.

z

Read the user's manual carefully before using this product. The user's manual provides important 
safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install 

the outdoor unit close to the sea shore, contact your local distributor.

Dealer

z

Specifications, designs and other content appearing in this brochure are current as of February 2015 but subject to change without notice.

Si041251EC

02/2015 AK.B

Summary of Contents for FTKD25GVM9

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Inverter Non Inverter Wall Mounted Type 2 0 2 5 3 5 kW Class 9000 13000 Btu h Class Si041251EC...

Page 2: ...V FTKS25JVMG FTKS35JVMG FTKS25JVMG9 FTKS35JVMG9 FTKV25NVM FTKV35NVM FTKV25NVM4 FTKV35NVM4 FTKV25NVMM FTKV35NVMM FTKV25NVMV FTKV35NVMV ATM09MV2S ATM13MV2S FTE25KV19 FTE35KV19 FTM25JV14 FTM35JV14 FTM25K...

Page 3: ...2 Front Panel 3 3 Front Grille 4 4 Horizontal Blades Vertical Blade ASSYs 5 5 Electrical Box 7 6 PCBs 9 7 Drain Pan Unit Swing Motor 13 8 Fan Motor 15 9 Indoor Heat Exchanger 17 10 Fan Rotor 20 Note T...

Page 4: ...the front panel Pull out the air filter downward and remove it 2 Remove the Titanium apatite photocatalytic air purifying filters The right and left filters are interchangeable Some models have an ai...

Page 5: ...g work Step Procedure Points 1 Open the front panel over the position where it stops 2 3 Slide the left rotary shaft to the right and release it Remove the right rotary shaft in the same way When reas...

Page 6: ...crews with the horizontal blades opened or removed 2 Unfasten the 3 hooks on the top of the front grille The convex marks on the front panel indicate the position of the hooks 3 Pull the upper part of...

Page 7: ...horizontal blade to the upper position and the small horizontal blade to the lower position Do not install them in the wrong place 1 Unfasten the center shaft while bending the horizontal blade upper...

Page 8: ...th a flat screwdriver 2 3 4 Unfasten the hooks at the upper 2 positions Remove the vertical blade ASSY Remove the other vertical blade ASSY in the same way A vertical blade ASSY has 6 fins It is impos...

Page 9: ...fixture Remove the 4 screws of the terminal board and disconnect the connecting wires 3 4 Disconnect the connector S6 Disconnect the connector S7 S6 swing motor S7 AC fan motor Put any excess wires be...

Page 10: ...r 8 Remove the screw of the electrical box 9 10 Lift up and pull the electrical box Unfasten the hook on top at the back by pressing it from above There is a hook also at the lower part of the back Wh...

Page 11: ...ws the appearance of the electrical box 2 Open the shield plate 3 Push the upper center of the shield plate and unfasten the 2 hooks Remove the shield plate 2 Release the indoor heat exchanger thermis...

Page 12: ...Remove the screw and remove the terminal board 4 Remove the signal receiver unit 1 Unfasten the 3 hooks and remove the signal receiver unit 2 Unfasten the 2 hooks Step Procedure Points Terminal board...

Page 13: ...EYE sensor PCB Some models have no INTELLIGENT EYE sensor PCB 1 Remove the INTELLIGENT EYE fixing plate by twisting it 2 3 Unfasten the 3 hooks on the right and remove the INTELLIGENT EYE sensor PCB T...

Page 14: ...CB 3 Disconnect the connector S27 from the display PCB 8 Remove the control PCB When reassembling the control PCB make sure that it is fastened by 2 upper hooks 1 2 Unfasten the 2 lower hooks Lift up...

Page 15: ...ull out the drain hose Place a plastic sheet under the drain pan to prevent from wetting the floor with remaining drain 1 Remove the screw at the right side of the drain pan unit 2 3 Press the right s...

Page 16: ...move the crank assembly 1 Remove the screw of the crank assembly 2 Unfasten the hook and remove the crank assembly The figure shows the position of the hook when the crank assembly has been removed St...

Page 17: ...ng off all power supplies before disassembling work Step Procedure Points 1 Release the fan motor lead wires from the hooks 2 Remove the screw of the fan rotor 3 4 Remove the 2 screws of the fan motor...

Page 18: ...Fan Motor Si041251EC 16 Removal Procedure 5 Unfasten the hook b and remove the fan motor fixing plate 6 Remove the fan motor Step Procedure Points Hook b R20216 R4394 Fan motor...

Page 19: ...re disassembling the refrigerant pipe If the refrigerant leaks repair the spot of leaking then collect all refrigerant from the unit After conducting vacuum drying recharge proper amount of refrigeran...

Page 20: ...iden the auxiliary piping 6 Unfasten the upper hook left with a flat screwdriver 7 Unfastening the lower hook left hold up the indoor heat exchanger by its left side and lift it up When reassembling t...

Page 21: ...oor Heat Exchanger Removal Procedure 19 8 9 When the left side is lifted the 2 hooks at the right side come off position Remove the indoor heat exchanger Step Procedure Points Indoor heat exchanger Ho...

Page 22: ...prox 5 mm 0 2 inch left 2 Tighten the screw until it stops Then give the screw one more turn 3 Rotate the fan rotor and confirm the fan motor and the fan rotor are installed appropriately 4 Tighten th...

Page 23: ...re 21 7 Remove the screw of the left side plate 8 Unfasten the 2 hooks and remove the left side plate 9 Press the bearing from the outside and remove the bearing Step Procedure Points R4414 Left side...

Page 24: ...35GVMV FTKS25 35JVMG FTN25 35JV1G FTXD25 35HVMV 03 2014 Si041251EB Model addition FTKS25 35JVMG9 FTKD25 35HVMV FTN25 35JV1G9 FTXS25 35GVMV 02 2015 Si041251EC Model addition FTKD25 35GVM9 FTKV25 35NVM...

Page 25: ...ies supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acces...