background image

• Indoor Units • R-22 • FT-C

1

3

• Split Sky Air • Indoor Units

5

3

Dimensional drawing & centre of gravity

3 - 1

Dimensional drawing

FT25,35CV1A9

3D045893

Up/down (automatic)

cooling, dry

Right/left (manual)

Blow

BLADE ANGLE

WIRELESS REMOTE 

CONTROLLER

(ARC423A18)

Signal transmitter

Flaps

Front panel fixed screws (inside)

Bottom

Left

Right

Rear

Signal receiver

Room temp. thermistor

Timer indicator lamp

Operation indicator lamp

Operation switch

Air flow (indoor)

REQUIRED SPACE

Terminal block with 
earth terminal

Name plate

50 min.

(space for performance)

50 min.

(space for performance)

30 m

in.

(s

pa

ce

 for

 p

erf

orm

an

ce

)

Drain hose
(connecting part I.D. ø 14.0, 
O.D. ø 18.0)
(the hose length of outside 
the unit is approx. 410)

Gas pipe 9.5 CuT (FT25C--) or

12.7 CuT (FT35C--)

(the length of pipe outside the

unit: about 340)

Liquid pipe 6.4 CuT

(the length of pipe outside

the unit: about 390)

Wall hole
ø 65 hole

Wall hole for

embedded piping

ø 65 hole

STANDARD LOCATIONS OF WALL HOLES

(for performance and maintenance)

(including mounting 

plate)

Summary of Contents for FT-C

Page 1: ...re room You have the choice out of 5 fan speeds to select Daikin s special dry programme reduces humidity in the room without variation in room temperature Powerful mode can be selected for rapid cool...

Page 2: ...ype Cross flow fan Quantity 1 1 1 1 Air Flow Rate Cooling High m min 8 3 8 4 16 2 17 5 Medium m min 6 7 7 0 14 0 15 0 Low m min 5 0 5 5 11 9 12 5 Fan Motor Quantity 1 1 1 1 Model 18F 22 18F 22 D43C 31...

Page 3: ...ler mounting plate Remote controller mounting plate Remote controller mounting plate Quantity 1 pc Item Remote control holder Quantity 1 pc Item Air purification filter with photocatalytic function Qu...

Page 4: ...Supply Name V1 V1 V1 V1 Phase 1 1 1 1 Frequency Hz 50 50 50 50 Voltage V 220 240 Current Nominal running current RLA Cooling A 0 22 0 22 0 18 0 20 Wiring connections For Power Supply Quantity 3 3 3 3...

Page 5: ...n indicator lamp Operation switch Air flow indoor REQUIRED SPACE Terminal block with earth terminal Name plate 50 min space for performance 50 min space for performance 30 min space for performance Dr...

Page 6: ...flow indoor REQUIRED SPACE Terminal block with earth terminal inside Model name plate 50 min space for maintenance 50 min space for performance 30 min space for performance Drain hose for VP13 connec...

Page 7: ...Indoor Units R 22 FT C 1 3 Split Sky Air Indoor Units 7 FT50 60CV1A9 4D040313H...

Page 8: ...023507H NOTE 1 Field piping specifications are as shown below Model name A FT25 9 5 CuT FT35 12 7 CuT Field piping 6 4 CuT Indoor unit 9 5 CuT Heat exchanger Thermistor on heat exchanger Cross flow fa...

Page 9: ...Split Sky Air Indoor Units 9 FT50 60CV1A9 4D040082F Field piping 6 4 CuT Indoor unit 12 7 CuT Heat exchanger Thermistor on heat exchanger Cross flow fan Fan motor Field piping 15 9 CuT 7 9 CuT Refrig...

Page 10: ...R2 Magnetic relay PCB1 PCB2 Printed circuit board R1T R2T Thermistor S1 S32 Connector SW7 Operation switch SA1 Surge arrester V1 V2 Varistor X1M Terminal strip Protective earth NOTES 1 Wiring diagram...

Page 11: ...netic relay PCB1 PCB4 Printed circuit board R1T R2T Thermistor S1 S38 Connector S1W Operation switch SA1 Surge arrester V1 V2 Varistor X1M Terminal strip Protective earth NOTES 1 Size length 70 x widt...

Page 12: ...0 V 50 Hz o o H A 39 and o o L A 31 4 Operation noise differs with operation and ambient conditions Approximate threshold hearing for continuous noise FT50CV1A9 4D045894 Octave band center frequency H...