• Split Sky Air • Indoor Units

12

• Indoor Units • R-22 • FT-C

6

Sound data

6 - 1

Sound pressure spectrum

FT25CV1A9

4D045896

Octave band center frequency (Hz)

Octav

e band

 s

o

und 

pre

ssure

 l

evel

 (

d

B

) (0 d

B

 = 0.0

002 µ

b

ar

)

Location of 

microphone

NOTES

1

Measurement was taken in an anechoic room.

2

The operation noise measuring method is in accordance 
with JISC9612.

3

Operating conditions:
Power source = 220-240 V, 50 Hz
o------o H (A = 38) and o- - - -o L (A = 28)

4

Operation noise differs with operation and ambient 
conditions.

Approximate 
threshold hearing 
for continuous 
noise

FT35CV1A9

4D029147B

Octave band center frequency (Hz)

Octave band soun

d pres

sure lev

el

 (dB) (0 dB = 0

.0002

 µ

b

ar)

Location of 

microphone

NOTES

1

Measurement was taken in an anechoic room.

2

The operation noise measuring method is in accordance 
with JISC9612.

3

Operating conditions:
Power source = 220-240 V, 50 Hz
o------o H (A = 39) and o- - - -o L (A = 31)

4

Operation noise differs with operation and ambient 
conditions.

Approximate 
threshold hearing 
for continuous 
noise

FT50CV1A9

4D045894

Octave band center frequency (Hz)

Octave band soun

d pres

sure lev

el

 (dB) (0 dB = 0

.0002

 µ

b

ar)

Location of 

microphone

NOTES

1

Measurement was taken in an anechoic room.

2

The operation noise measuring method is in accordance 
with JISC9612.

3

Operating conditions:
Power source = 220-240 V, 50 Hz
o------o H (A = 43) and o- - - -o L (A = 35)

4

Operation noise differs with operation and ambient 
conditions.

Approximate 
threshold hearing 
for continuous 
noise

FT60CV1A9

4D045895

Octave band center frequency (Hz)

Octave band soun

d pres

sure lev

el

 (dB) (0 dB = 0

.0002

 µ

b

ar)

Location of 

microphone

NOTES

1

Measurement was taken in an anechoic room.

2

The operation noise measuring method is in accordance 
with JISC9612.

3

Operating conditions:
Power source = 220-240 V, 50 Hz
o------o H (A = 46) and o- - - -o L (A = 36)

4

Operation noise differs with operation and ambient 
conditions.

Approximate 
threshold hearing 
for continuous 
noise

Summary of Contents for FT-C

Page 1: ...re room You have the choice out of 5 fan speeds to select Daikin s special dry programme reduces humidity in the room without variation in room temperature Powerful mode can be selected for rapid cool...

Page 2: ...ype Cross flow fan Quantity 1 1 1 1 Air Flow Rate Cooling High m min 8 3 8 4 16 2 17 5 Medium m min 6 7 7 0 14 0 15 0 Low m min 5 0 5 5 11 9 12 5 Fan Motor Quantity 1 1 1 1 Model 18F 22 18F 22 D43C 31...

Page 3: ...ler mounting plate Remote controller mounting plate Remote controller mounting plate Quantity 1 pc Item Remote control holder Quantity 1 pc Item Air purification filter with photocatalytic function Qu...

Page 4: ...Supply Name V1 V1 V1 V1 Phase 1 1 1 1 Frequency Hz 50 50 50 50 Voltage V 220 240 Current Nominal running current RLA Cooling A 0 22 0 22 0 18 0 20 Wiring connections For Power Supply Quantity 3 3 3 3...

Page 5: ...n indicator lamp Operation switch Air flow indoor REQUIRED SPACE Terminal block with earth terminal Name plate 50 min space for performance 50 min space for performance 30 min space for performance Dr...

Page 6: ...flow indoor REQUIRED SPACE Terminal block with earth terminal inside Model name plate 50 min space for maintenance 50 min space for performance 30 min space for performance Drain hose for VP13 connec...

Page 7: ...Indoor Units R 22 FT C 1 3 Split Sky Air Indoor Units 7 FT50 60CV1A9 4D040313H...

Page 8: ...023507H NOTE 1 Field piping specifications are as shown below Model name A FT25 9 5 CuT FT35 12 7 CuT Field piping 6 4 CuT Indoor unit 9 5 CuT Heat exchanger Thermistor on heat exchanger Cross flow fa...

Page 9: ...Split Sky Air Indoor Units 9 FT50 60CV1A9 4D040082F Field piping 6 4 CuT Indoor unit 12 7 CuT Heat exchanger Thermistor on heat exchanger Cross flow fan Fan motor Field piping 15 9 CuT 7 9 CuT Refrig...

Page 10: ...R2 Magnetic relay PCB1 PCB2 Printed circuit board R1T R2T Thermistor S1 S32 Connector SW7 Operation switch SA1 Surge arrester V1 V2 Varistor X1M Terminal strip Protective earth NOTES 1 Wiring diagram...

Page 11: ...netic relay PCB1 PCB4 Printed circuit board R1T R2T Thermistor S1 S38 Connector S1W Operation switch SA1 Surge arrester V1 V2 Varistor X1M Terminal strip Protective earth NOTES 1 Size length 70 x widt...

Page 12: ...0 V 50 Hz o o H A 39 and o o L A 31 4 Operation noise differs with operation and ambient conditions Approximate threshold hearing for continuous noise FT50CV1A9 4D045894 Octave band center frequency H...

Reviews: